29
Go to cover page
5.9 Checking the interface circuit of sync signal
5.9.1 Checking the control circuit of horizontal sync pulse
OK
NG
Failure Point
Video cable is failure.
OK
NG
Failure Point
1) Printed wire broke between P302 pin13
and I305 pin27.
2) FB309, R321 are short.
3) D307 or R324 or C327 is short.
Failure Point
Process "Checking the resolution change IC
movement" section.
Check the horizontal sync
signal on P302 pin13 TTL
level.
Check the horizontal sync
signal on I305 pin27 TTL
level.
5. Troubleshooting (continued)
ACER P203W