Confidential
4-2
H6500
4-4-2 Burn-In Test
- Temperature: 15°C~35°C
- Circumstance brightness: Normal environment
- Screen size: No concern
- Display mode: ECO mode
- After repairing each unit, it should be Run-in (refer to the below table).
< Figure: Zone A, Zone B & Frame (as green line) Definition, Active area = Zone A + Zone B >
4-4 Test Condition
4-4-1 Normal Test Condition
- Circumstance brightness: Dark room less than 10.0 lux
- Screen size: 60 inches
Screen Defects
Defect specification table
Order
Symptom
Pattern
Criteria
Bright pixel (dots)
Gray 10 pattern
A+B ≤
2
Dark pixel (dots)
White pattern
A+B ≤ 6
3
Bright blemish
Gray 15 pattern
A+B ≤ 10
4
Dark blemish
Blue 60 pattern
A+B ≤ 10
5
Bright dot on frame
Gray 10 pattern
≤ 1
6
Unstable pixel
White & Black pattern
A+B ≤ 1
7
Adjacent dark pixel
White & Black pattern
A+B = 0