H5350
Confidential
4-0
3. Ful On/Full Off Contrast
Procedure
- Full white pattern & full black pattern
- Use CL100 to measure brightness values of full
white pattern P5 & full black pattern B5 ( see im
-
age: full white)
- Follow Contrast formula to calculate contrast
values.
☼ Contrast Formula
P5/B5
note: P5=center of white image
B5=center of black image.
Criteria
- 1500:1
4. Uniformity
Procedure
- Full white pattern
- Use CL100 to measure brightness values of
P1~P9 (see image: full white).
- Follow the Uniformity formula to calculate
average values.
☼ Uniformity Formula
ANSI Uniformity = Avg. (P1, P3, P7, P9)
P5
Criteria
- 65%
4-11 Others
1. Functional Inspection
Keypad button
- All keypad buttons must operate
smoothly.
General
- All OSD functions must be
checked for functionality. When
OSD menu is displayed, there
x 100%
Full black pattern
Содержание H5350 Series
Страница 14: ...H5350 Confidential 1 Remote Control and Control Panel Layout ...
Страница 18: ...H5350 Confidential 1 13 ...
Страница 19: ...H5350 Confidential 1 14 Bottom Cover Dimension ...
Страница 53: ...H5350 Confidential 2 34 5 Screw 2 hex screws 2 34 Assemble Top Shielding 1 Screw 7 screws on the Top Shielding ...
Страница 74: ...H5350 Confidential 5 6 Click Next 7 Click Next 8 Writing system registry values 9 Click Finish ...
Страница 88: ...H5350 Confidential II 5 3 ASSY LAMP DRIVER MODULE H5350 1 2 4 6 ...
Страница 90: ...H5350 Confidential IV ASSY MAIN BD MODULE H5350 13 10 ...
Страница 93: ...H5350 Confidential VII ASSY HOUSING MODULE H5350 ...
Страница 95: ...H5350 Confidential IX BUY ASSY TOP COVER ADD PAINT H5350 ...
Страница 101: ...H5350 Confidential XV A K H5350 8 7 9 1 2 3 4 5 6 10 ...
Страница 103: ...H5350 Confidential XVII D C H5350 6 5 3 4 1 2 7 8 9 ...
Страница 105: ...H5350 Confidential XIX D P H5350 19 12 9 4 3 1 13 11 18 10 17 15 6 7 8 14 2 16 5 ...