H5350
Confidential
4-2
4-4 Test Condition
- Circumstance brightness: Dark room less than 5.0 lux.
- Inspection distance: 1.8m~2.5m functional inspection.
- Screen size: 60 inches diagonal
- After repairing each
H5350
, the unit should be run-in (refer to the table below)
Symptom
Run-in Time
Normal repair
2 hours
NFF
4 hours
Auto shut down
6 hours
- Enter Burn-In Mode
* Cycle setting is based on the defect symptoms. ie: If it is NFF, the run-in time is 4 hours. You have
to set the lamp on for 50 min. and lamp off for 10 min for 4 cycles.
Press power > left > left > Menu
Choose Burn-In Test > enter
Lamp On (Min)
Press right key to adjust the time (50)
Lamp Off (Min)
Press right key to adjust the time (10)
Set burn in cycle
Press right key to adjust the cycle
After setting up the time, choose Burn-In mode and hit enter
Screen Defects (While replacing DMD Chip, DMD BD and MB)
< Figure: Zone A &B Definition >
Содержание H5350 Series
Страница 14: ...H5350 Confidential 1 Remote Control and Control Panel Layout ...
Страница 18: ...H5350 Confidential 1 13 ...
Страница 19: ...H5350 Confidential 1 14 Bottom Cover Dimension ...
Страница 53: ...H5350 Confidential 2 34 5 Screw 2 hex screws 2 34 Assemble Top Shielding 1 Screw 7 screws on the Top Shielding ...
Страница 74: ...H5350 Confidential 5 6 Click Next 7 Click Next 8 Writing system registry values 9 Click Finish ...
Страница 88: ...H5350 Confidential II 5 3 ASSY LAMP DRIVER MODULE H5350 1 2 4 6 ...
Страница 90: ...H5350 Confidential IV ASSY MAIN BD MODULE H5350 13 10 ...
Страница 93: ...H5350 Confidential VII ASSY HOUSING MODULE H5350 ...
Страница 95: ...H5350 Confidential IX BUY ASSY TOP COVER ADD PAINT H5350 ...
Страница 101: ...H5350 Confidential XV A K H5350 8 7 9 1 2 3 4 5 6 10 ...
Страница 103: ...H5350 Confidential XVII D C H5350 6 5 3 4 1 2 7 8 9 ...
Страница 105: ...H5350 Confidential XIX D P H5350 19 12 9 4 3 1 13 11 18 10 17 15 6 7 8 14 2 16 5 ...