Remote Access Configuration
The remote access configuration submenu lets you specify settings related to the syste’s remote
management features.
Parameter
Description
Option
Remote Access
Enables or disables remote access.
Selecting Serial enables remote access and opens
a submenu to configuration system parameters.
Disabled
Serial
Serial Port Number
Default is “COM1” when remote access is set to
“Serial”
COM1
COM2
Serial Port Mode
COM1 default is 115.2K
COM2 default is 19.2K
115200 8,n,1
57600 8,n,1
19200 8,n,1
POST-Boot Support
Default is “Disabled”
If Enabled, system will keep redirection connection
active after booting to OS.
If Disabled, the connection will be deactivated.
Disabled
Enabled
Terminal Type
Default is PC-ANSI, which is the standard PC-type
terminal. VT100 works for English as the select
language. VT-UTF8 uses Unicode.
PC ANSI
VT100
VT-UTF8