23
4.12 Environment Requirements
4.12.1 Non-adjusting operation
25
℃
±
10
℃
4.12.2 Operating
Temperature 0
°
C to +40
°
C
Relative Humidity
10% to 90%
Altitude
Sea level to 8,000ft
4.12.3 Storage of shipment
Temperature -20
°
C to + 60
°
C
Relative Humidity
10% to 90%
Altitude
Sea level to 40,000ft
TEST PROCEDURUE:
Put in temperature chamber under 60
°
C
Time: 24 hours
Back to room temperature
Time: 4 hours
Put in temperature chamber under -20
°
C Time: 24 hours
Back to room temperature
Time: 4 hours
The process repeat 2 times.