19
4.10.9 Misconvergence
The display must conform to all the following requirements:
Maximum convergence error.
Area
Horizental Direction
Vert. Direction
A
Center field of 195mm diameter
0.30mm 0.30mm
B
Square field of 260 x 195 mm
0.40mm 0.40mm
Table 6 : Misconvergence
The maximum convergence error shall be measured for a white spot or line, and represents the
maximum distance between the energy centers of any two primary colors. The central area is defined as
the area within a circle centered on the CRT faceplate having a diameter equal to the display vertical
dimension.
Figure 14
Содержание AM501
Страница 1: ...AM 501 Service Guide 15 inch CRT Monitor ...
Страница 4: ......
Страница 36: ...32 6 9 Control And Conmect Layout 6 9 1 Main PCB ...
Страница 37: ...33 7 0 FUNCTION BLOCK DIAGRAM 7 1 Monitor Portion ...
Страница 38: ...34 8 0 POWER SUPPLY PORTION ...
Страница 43: ...39 APPENDIX A PARTS LIST ...
Страница 55: ...51 APPENDIX B DISPLAY UNTY ASSEMBLY ...
Страница 56: ...52 ...
Страница 61: ...57 ...
Страница 62: ...58 ...
Страница 65: ...61 APPENDIX C CRT YOKE ASSEMBLY ...
Страница 66: ...62 ...
Страница 68: ...64 ...
Страница 70: ...66 APPENDIX D P C B A ASSEMBLY ...
Страница 73: ......
Страница 74: ......
Страница 75: ......
Страница 76: ......