8
Electrical Requirements
Standard Test Conditions
All tests shall be performed under the following conditions, unless otherwise specified.
Ambient light
:
Dark room (<1cd/m2)
Viewing distance
:
40 cm for LCD performance, 20 cm for LCD failures
Warm up time
All specifications
:
>
30 minutes
Fully functional
:
5 seconds
Measuring equipment
:
Chroma 7120 signal generator or equivalent, directly
Connected to the monitor under test.
Minolta CA100 photometer, or equivalent
Control settings
User brightness control
:
Set to Factory preset value (cut off raster)
User contrast control
:
T Set to factory preset value, which allows that the brightest two
of 32 linear distributed gray-scales (0
~
700mv) can be
distinguished.
User red/white balance,
Green/white balance and
Blue/white balance control
:
In the center (unless otherwise specified)
Power input
:
230V
±
5
%
,
50
±
3 Hz
Ambient temperature
:
20+5
℃
Measurement systems
The units of measure stated in this document are listed below:
1 gamma = 1 nano tesla
1 tesla = 10,000 gauss
cm = in x 2.54
Lb = kg x 2.2
Degrees F = [°C x 1.8] + 32
Degrees C = [°F - 32]/1.8
u' = 4x/(-2x + 12y + 3)
v' = 9y/(-2x + 12y + 3)
x = (27u'/4)/[(9u'/2) - 12v' + 9]
y = (3v')/[(9u'/2) - 12v' + 9]
nits = cd/(m2) = Ft-L x 3.426
lux = foot-candle x 10.76
Содержание AL2051
Страница 1: ...1 Acer AL2051W Service Guide ...
Страница 14: ...14 Software Flow Chart 1 2 N Y 5 Y N 10 Y N 12 Y N 7 Y N 6 4 3 8 9 14 11 13 Y N 15 Y N 16 17 19 Y N 18 ...
Страница 22: ...22 b The Description For Control Function ...
Страница 23: ...23 ...
Страница 27: ...27 1 Remove two screws Fig 1 2 Remove the hinge cover Fig 2 3 Remove the one screw Fig 3 Fig 1 Fig 2 Fig 3 ...
Страница 42: ...42 Exploded Diagram Model AL2051W ...
Страница 45: ...45 10 SPEAKERS 78G 322 3B 11 BASE 34G1785 QW B 12 BASE BACK COVER 33G4965AQT 1L 13 HINGE HOLDER 20G 041 1 ...
Страница 53: ...53 Power Inverter board ...