Acer
Service Manual
8
for power MOSFET U501, U502.
2.
OZ9938 provides two drive signals for U501, U502, and they work in push pull topology driving, two
transformers are connected in parallel with each transformer driving two lamps in series. Turning each
N-Channel MOSFET “on/off” complementarily, produces an alternating current through the transformer
primary and secondary. The “on” duration of the switches determines the amount of energy delivered to the
CCFLs. R504, C504, R505, C505, R532, C529, R530, C522 are snubber networks, they suppress Voltage
transient spike in drain of power MOSFET.
3. R506, R510, C509, C513, C514, R525, R531, C528, C525, and C527 are connected between high voltage
output connector and ground, the divided AC voltage is inverted DC voltage through D502, D503, D508,
and D509. The sense voltage feed back to VSEN (pin 6 of IC501) for an over voltage/over current condition
during normal operation. R528, R533 are current sense resistor, current sense signal feed back to Isense (pin
5 of IC501) for lamp “ON” detection.
Содержание AL1917W C
Страница 1: ...Acer Service Manual 0 Service Manual LCD Monitor Acer AL1917W ...
Страница 10: ...Acer Service Manual 9 Chapter 4 Disassembly Assembly 1 Exploded Diagram ...
Страница 23: ...Acer Service Manual 22 3 No raster ...
Страница 28: ...Acer Service Manual 27 Attachment 1 Bill of Material PCBA P I ...
Страница 29: ...Acer Service Manual 28 ...
Страница 30: ...Acer Service Manual 29 ...
Страница 31: ...Acer Service Manual 30 PCBA IF ...
Страница 32: ...Acer Service Manual 31 ...
Страница 33: ...Acer Service Manual 32 PCBA KEY PAD ...
Страница 42: ...Acer Service Manual 41 Attachment 3 PCB Layout ...
Страница 43: ...Acer Service Manual 42 ...
Страница 44: ...Acer Service Manual 43 ...