Attachment 

Plug and Play

 

 

 

The product provides the latest VESA 

plug and play

function to prevent complicated 

and time-consuming installation procedures. The

 plug and play

 function allows your 

computer system to identify the LCD display easily and set up the functions of the 
LCD display automatically. 

The LCD display transfers the 

Extended Display Identification Data

 (EDID) to your

computer system via the 

Display Data Channel

 (DDC), so that your computer can 

use the self-setting function of the LCD display.

 

 

Power Saver 

 

 

 

 

 

 

 

The LCD display has a built-in Power Control System (

Power Saver

). 

When the LCD display is not operated during a certain time, the Power Control 
System will brings the LCD display into low voltage status automatically to save 
power. Move the mouse slightly or press any key to return to the normal operation. 

The 

Power Saver

 function can only be operated by the display card of the computer 

system. You can set up this function from your computer. 

The LCD display is compatible with EPAENERGY STAR NÜTEK when used with 
VESA DPMS. 

To save power and extend the life of the product, turn off the LCD display power 
supply when it is not used or when remaining idle for a long time. 

 

Troubleshooting 

 

Power LED does not 

light

 

 

Check that the power switch is turned on. 

Make sure that the power cable is connected. 

 

Icon off

 

 

 

 

 

 

 

 

 

 

 

 

Check that the power switch is turned on. 

Make that the power cable is connected. 

Ensure that the signal cable is inserted in the receptacle appropriately. 

The Power Saver may turn off the display automatically during the operation. Make 
sure that the display is restored when you press any key from the keyboard. 

 

Color Default

 

Refer to “Color Temperature Adjustment” to adjust RGB color or select color 
temperatures. 

Instability or Ripple

 

Remove the electronic equipment in the vicinity that may cause EMI interference. 

Check the signal cable of the display and ensure that no pin is bent. 

 

Image Offset or 

wrong Size

 

Press the auto adjustment button to optimize the screen automatically. 

Set up the reference position. 

 

 
 

Содержание AL1512

Страница 1: ...stallation Safety 1 Cleaning Safety 1 Components and Accessories 1 Usage 2 Installation Guide 2 Adjustment of Display 3 Operation 4 Adjustment of Screen 5 Attachment 6 Plug and Play 6 Power Saver 6 Troubleshooting 6 Technical Specifications 7 Display Mode 8 ...

Страница 2: ...leaving any oil sludge on the surface of the display Install your LCD display at the place where the risk of dust contamination is low Take moisture proof and ventilation measures to protect your LCD display Don t install your LCD display near any heat source such as kitchen tables ovens or fire sources or in the sun Install your LCD at the place where children will not touch it to avoid electric ...

Страница 3: ... eyes and ensure premium quality don t install your LCD display near windows or with backlight Keep the display away from your eyes at least by 30 cm The upper edge of the display should be a little higher than your sight Adjust the front and back dip angles of the display based on your visual angle so that you can view the display comfortably Quick Installation Complete the following steps for qu...

Страница 4: ...al Cable Audio Cable Transformer DC end Adjustment of Display Key Definition 1 Power Source Power On Off Green indication Power is on and normal Orange indication Sleep status in the energy saving mode Colorless indication Power off 2 MENU OSD Manu Press this button to enter OSD Press it again to exit OSD 3 Plus 4 Minus Press this button for selection or adjustment when OSD is shown Press this but...

Страница 5: ... Click or to select the function to be adjusted as shown in the following figure 3 Click the MENU button to select the function to be adjusted 4 Click or to change current settings 5 To exit OSD select to close the OSD window and save changes To change other settings repeat steps 2 4 Bright Contract Adjustment Phase Clock pulse Adjustment Horizontal Vertical Adjustment Color Temp Adjustment Langua...

Страница 6: ...ut adjustment only N A Warm Color Temp Set up the color temp to be warm white color N A Cold Color Temp Set up the color temp to be cold white color User Definition Red User Definition Green User Definition Blue Adjust red green blue gain N A English N A 繁體中文 N A Deutsch N A Français N A Español N A Italiano N A 简体中文 N A 日本語 Select the language you want Horizontal Move OSD left and right Vertical ...

Страница 7: ...an set up this function from your computer The LCD display is compatible with EPAENERGY STAR NÜTEK when used with VESA DPMS To save power and extend the life of the product turn off the LCD display power supply when it is not used or when remaining idle for a long time Troubleshooting Power LED does not light Check that the power switch is turned on Make sure that the power cable is connected Icon...

Страница 8: ...al Mode Simulated video frequency 0 7 Vpp 75Ω separate SYNC and composite SYNC SYNC Frequency Horizontal 28kHz 63kHz x Vertical 55Hz 78 Hz Input Signal Max Pixel Clock 80MHz Input Terminal Image D Sub 15 PIN VESA Power Transformer AC100 240Volts 60 50Hz Power Consumption 33W Standby 3W Temperature 5 35 operation 20 55 storage Environmental Conditions Humidity 20 80 operation 20 85 storage Actual D...

Страница 9: ...r display card Display Mode Hor Frequency kHz Vert Frequency Hz Pixel Frequency MHz SYNC Polarity H V VESA VGA 640x480 31 469 59 940 25 175 37 861 72 809 31 500 37 500 75 000 31 500 SVGA 800x600 35 156 56 250 36 000 37 879 60 317 40 000 48 077 72 188 50 000 46 875 75 000 49 500 XGA 1024x768 48 363 60 004 65 000 56 476 70 069 75 000 60 023 75 029 78 750 VGA TEXT 720 x 400 31 469 70 087 28 322 Macin...

Отзывы: