background image

Warranty  

13

Retain Original Receipt For Your Records

Limited Warranty

This Limited Warranty is effective June 28, 2016 and replaces all undated warranties and warranties dated before June 28, 2016.
ACE warrants to the original consumer purchaser (“Purchaser” or “You”) that its products are free from defects in material and 

workmanship for a period of twelve (12) months from the date of the original consumer purchase. If, within twelve (12) months 

from the original consumer purchase, any such product shall prove to be defective, it shall be repaired or replaced at ACE’s 

option, subject to the terms and conditions set forth herein. Note that this limited warranty applies to manufacturing defects 

only and not to ordinary wear and tear. All mechanical devices need periodic parts and service to perform well. This limited 

warranty does not cover repair when normal use has exhausted the life of a part or the equipment.
The original purchase receipt and product warranty information label are required to determine warranty eligibility. Eligibility 

is based on purchase date of original product – not the date of replacement under warranty. The warranty is limited to repair or 

replacement of original purchased product only, not replacement product (i.e. one warranty replacement allowed per purchase). 

Purchaser pays all removal, installation, labor, shipping, and incidental charges.
For parts or troubleshooting assistance, DO NOT return product to your retail store - contact ACE Customer Service at 800-422-

1551.
Claims made under this warranty shall be made by returning the product (except sewage pumps, see below) to the retail outlet 

where it was purchased immediately after the discovery of any alleged defect. ACE will subsequently take corrective action 

as promptly as reasonably possible. No requests for service will be accepted if received more than 30 days after the warranty 

expires. Warranty is not transferable and does not apply to products used in commercial/rental applications.

Sewage Pumps

DO NOT return a sewage pump (that has been installed) to your retail store. Contact ACE Customer Service. Sewage pumps that 

have seen service and been removed carry a contamination hazard with them. 
If your sewage pump has failed:
•  Wear rubber gloves when handling the pump; 
•  For warranty purposes, return the pump’s cord tag and original receipt of purchase to the retail store;
•  Dispose of the pump according to local disposal ordinances. 

Exceptions to the Twelve (12) Month Limited Warranty

Product

Warranty Period

4” Submersible Well Pumps

3 Years

General Terms and Conditions; Limitation of Remedies

You must pay all labor and shipping charges necessary to replace product covered by this warranty. This warranty does not apply 

to the following: (1) acts of God; (2) products which, in ACE’s sole judgment, have been subject to negligence, abuse, accident, 

misapplication, tampering, or alteration; (3) failures due to improper installation, operation, maintenance or storage; (4) atypical 

or unapproved application, use or service; (5) failures caused by corrosion, rust or other foreign materials in the system, or 

operation at pressures in excess of recommended maximums.
This warranty sets forth ACE’s sole obligation and purchaser’s exclusive remedy for defective products.
ACE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, 

INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. 

THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied 

warranty lasts, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You 

may also have other rights which vary from state to state.

ACE • Phone: 1-800-422-1551 (U.S.A only) • 7am to 5pm CST

Содержание ACE10C Convertible 1 HP

Страница 1: ...llation Manual WARRANTY Product defects covered for 12 months from date of purchase Receipt is required for warranty claim ESPA OL P GINAS 15 28 Guide D utilisation GARANTIA los defectos de los produc...

Страница 2: ...burn or cause death Read instructions before installing To avoid dangerous or fatal shock hazard turn off power and ground motor before connecting motor to electrical power supply Do not ground to a g...

Страница 3: ...p is disconnected from power before servicing or handling pump Remove the cover from the pressure switch Connect the bare copper ground to the ground screw in the pressure switch Connect the power sup...

Страница 4: ...BE AIRTIGHT Even a pinhole leak will prevent the proper operation of the pump this is the most common problem Use thread compound on all threaded joints unless specified otherwise Pump Installation I...

Страница 5: ...to connect the PVC elbow to the 1 1 4 male PVC adapter in the front of the pump 11 Apply 2 3 wraps of PTFE pipe thread sealant tape tape to the male threads on the discharge tee Using pipe wrench thr...

Страница 6: ...Well General Materials for Well Points only Enough galvanized 1 1 4 pipe and drive couplings to reach from operating depth to one foot above ground level One 1 1 4 galvanized elbow One 1 1 4 galvanize...

Страница 7: ...le PVC adapters One 1 x 4 nipple REMINDER ALL JOINTS AND CONNECTIONS MUST BE AIRTIGHT A SINGLE PINHOLE LEAK WILL PREVENT THE PROPER OPERATION OF THE PUMP USE THREAD COMPOUND ON ALL THREADED CONNECTION...

Страница 8: ...he 1 and 1 1 4 PVC elbows 10 Prime pump as described in Priming the Pump 11 Open pressure regulator kit Apply 2 3 wraps of PTFE pipe thread sealant tape tape to the male threads on the body of the pre...

Страница 9: ...e ACE5C and 32 PSI for the ACE10C If pressure fails to build within five minutes stop motor remove pressure regulator from pump add more water and try again If you install your pump with a 2 single pi...

Страница 10: ...acity is reduced In deep wells the ejector may have improper size and depth setting Motor overheats and shuts off overload Motor voltage does not match power supply voltage See page 3 Improper wire si...

Страница 11: ...PASFK P2 Seal and Gasket Kit ACE PK 3 5 ACE PK 10 ACE PK 3 5 Kits Include Overhaul Kit 1 2 HP Key Nos 4 5 6 7 8 12 Overhaul Kit 1 HP Key Nos 4 5 6 7 8 12 Ejector Kit Key Nos 7 12 18 19 20 2 21 2 REPAI...

Страница 12: ...user Plate 1 10 Diffuser Plate Screw 3 11 Venturi 1 12 Nozzle 1 13 Diffuser Plate O Ring 1 14 Pump Body 1 15 Pump Housing Screw 4 16 Pipe Plug 2 17 Tubing 1 18 Pressure switch 1 Part ACE10S Descriptio...

Страница 13: ...nsferable and does not apply to products used in commercial rental applications Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact ACE Customer Service Sewag...

Страница 14: ...14 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 15: ...ocar la muerte Lea las instrucciones antes de instalar la bomba Para evitar el peligro de choques el ctricos graves o mortales ponga el motor la posici n de apagado y con ctelo a tierra antes de conec...

Страница 16: ...15 12 14 3 2 10 14 5 5 2 8 14 8 4 2 6 12 14 3 ACE10S 1 115 230 18 6 9 3 20 15 12 14 3 2 18 14 8 4 2 6 14 14 2 6 12 14 3 ACE10C 1 115 230 14 8 7 4 20 15 12 14 3 2 8 14 8 4 2 6 14 14 2 6 12 14 3 Ground...

Страница 17: ...de PIEZAS JUEGOS DE REPARACI N incluye eyector tubo venturi empaquetadura pernos y tap n Herramientas necesarias para todo tipo de instalaciones de bombas Llave para tubos corona para tubos llave ajus...

Страница 18: ...lantera del eyector Apri telo a mano entonces apri telo un cuarto de vuelta con una llave 10 Pegue todos los tramos de tubo y adaptadores de cloruro de polivinilo que necesite para conectar el codo de...

Страница 19: ...que la lanza extractora en el suelo seg n le indiquen las instrucciones incluidas con la lanza extractora Use tanta tuber a galvanizada y tantos manguitos de tuber a de hincar como sea necesario para...

Страница 20: ...ba tuber a de presi n Un codo de cloruro de polivinilo de 1 Dos adaptadores macho de cloruro de polivinilo de 1 1 4 Una boquilla de 1 x 4 RECORDATORIO TODAS LAS JUNTAS Y CONEXIONES DEBER N SER HERM TI...

Страница 21: ...ilo y sobre la carcasa del pozo NO PERMITA que la ensambladura caiga por el pozo Coloque la ensambladura de tal manera que sobresalgan doce pies 3 65 metros del tubo de cloruro de polivinilo del sello...

Страница 22: ...ue de presi n a diafragma se deber graduar a 28 PSI La instalaci n final deber ser como la indicada en el diagrama que se muestra a la derecha ADVERTENCIA Peligro de explosi n Si usted cambia las grad...

Страница 23: ...ector est a m s de 10 pies 3 metros por debajo del nivel de bombeo se reducir la capacidad de bombeo En los pozos profundos es posible que el tama o del eyector y la profundidad sean inadecuados El mo...

Страница 24: ...14 Aro t rico de la placa 1 del difusor Clave Descripci n No de la pieza Cant 15 Manguera 1 16 Base 1 17 Man stato 1 18 Empaquetadura del eyector 1 19 Unidad del eyector 1 20 Arandela 2 21 Tornillo p...

Страница 25: ...1 Venturi 1 12 Boquilla 1 13 Aro t rico de la placa del difusor 1 14 Unidad de la bomba 1 15 Tornillo de la caja de la bomba 4 16 Tap n de la tuber a 2 17 Manguera 1 18 Man stato 1 Modelo ACE10S ACE10...

Страница 26: ...30 d as despu s del vencimiento de esta garant a Esta garant a no es v lida para productos que se utilicen para fines comerciales o de alquiler T rminos y condiciones generales Usted deber pagar por t...

Страница 27: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 28: ......

Отзывы: