1 2
Mode
OFF
ª
OFF
ª
Reserved mode, no use.
OFF
ª
ON
©
Recording: Connect the monitor to the DVI-monitor connector. Once the recording
process is completed, EX-G043 has copied the EDID from the monitor into its flash
memory and the green LED will turn off.
ON
©
ON
©
Reset to default: Write the default EDID back into EX-G043 to replace the existing
EDID in the EX-G043. Once the writing process is completed, the green LED will
turn off.
ON
©
OFF
ª
Connection mode: Set DIP switches at this position before you connect your
computer to the EX-G043.
To avoid initiating undesired errors during switching between modes (e.g. changing from
Recording mode to Connection mode might overwrite the EDID of the display in the
EX-G043 by the default EDID), please unplug the power cord before you change one of the
above modes to another. Plug in the power cord after you have changed the position of the
DIP switches.
Hardware Installation
1. Rea
d the EDID from a display
1. Set the DIP switches at the button of EX-G043 at 1-off 2-on.
2. Connect your monitor to the EX-G043 and plug in 5V DC power cord.
3. Remove 5V DC power cord when the green LED turns off.
4. Connect the EX-G043 to your computer by a DVI cable and boot up your computer.
2. Recall the default universal EDID
1. Set the DIP switches at the button of EX-G043 at 1-on 2-on.
2. Plug in 5V DC power cord and remove 5V DC power cord when the green LED turns off.
3. Connect your monitor to the EX-G043
4. Connect the EX-G043 to your computer by a DVI cable and boot up your computer.
3. Write EDIDs to displays
1. Set the DIP switches at the button of EX-G043 at 1-ON
ª
/ 2-OFF
©
.
2. Plug in 5V DC power cord.
3. Connect your monitor (DVI cable) and computer (RS-232 cable) to the EX-G043.
4. Boot up your computer and install the software.
ACE PLUS CORP.
Headquarters :
9F-2., No. 190 Sec. 2 Jung Shing Rd.,Hsin-dian,
Taipei, Taiwan 231
TEL: +886-2-2912-4201
FAX: +886-2-2912-3164
Website:
www.ace-plus.com
Page
5
of
8