P/N  910-0603-00

Advanced Calibration Designs, Inc.

Instruction Manual

Calibration Gas Generator

Advanced Calibration Designs, Inc.

CAL 2000

Содержание Cal 2000

Страница 1: ...05USA Telephone 520 290 2855 Fax 520 290 2860 TollFree 800 737 0223 Email acd goACD com Web www goACD com P N 910 0603 00 AdvancedCalibrationDesigns Inc InstructionManual CalibrationGasGenerator Advan...

Страница 2: ...V Maintenance Page 16 VI Troubleshooting Page 17 VII Standard Warranty Page 19 VIII Accessory Items Parts List Page 21 IX Instrument Specifications Page 23 ATENCI N ATTENTION Para bajar la version del...

Страница 3: ...can lead to improper calibrations This instrument conforms to the protection requirements of the EC DIRECTIVE 89 336 EEC on Electromagnetic Compatibility EMC in accordance with the provisions of Stat...

Страница 4: ...mp may be disabled for use in calibrating sample draw instruments Electrochemical Generating Cell The electrochemical generating cell contains an electrolyte solution and either inert or consumable el...

Страница 5: ...of the instrument This is done by pulling each of the plunger feet on the bottom of the instrument Once all of the plungers have been pulled out the bottom cover is simply removed from the instrument...

Страница 6: ...s on how to change the menu language Digital Display The Cal 2000 has a liquid crystal display LCD located on the front of the instrument This display is protected by a thin clear plastic cover that i...

Страница 7: ...to 1 0 LPM With the pump disabled it is used to measure the air flow rate drawn through the Cal 2000 by an external pump This information is used to adjust the cell current to the desired ppm The flow...

Страница 8: ...act specifications of the AC adapter Hard Body Instrument Case A water resistant padded instrument case is available for storage and shipping of the Cal 2000 The case is made out of rugged high impact...

Страница 9: ...h immediately thereafter The instrument will sequence through several screens as follows Please Note If you would like to change the language of the menus see section IV Menu Options Foreign Language...

Страница 10: ...battery status Please Note If you have a ClO2 or H2S cell in the unit you will receive an additional message at this time Please refer to section IV Menu Options for additional information When the ai...

Страница 11: ...itch You may adjust the ppm upwards by pressing the POWER switch arrow up or downwards by pressing the SELECT switch arrow down If you set the ppm to 000 ppm the instrument will not generate any gas a...

Страница 12: ...mply reduce the flow rate of the instrument Once the flow and concentration have been set the instrument will enter the stabilization period and the display will alternate between the following three...

Страница 13: ...will purge itself of gas for 300 seconds and then automatically shut off At any time during this period you may turn the instrument back on by pressing the SELECT switch and entering the status screen...

Страница 14: ...witch when the flow status screen is displayed When the flow set screen appears adjust the flow to read 0 0 LPM The ppm output screen will then read 000 ppm You will be unable to set the ppm until the...

Страница 15: ...ppm as described earlier If the flow rate changes significantly during this period the instrument will attempt to re stabilize at the new flow rate The instrument operates identically to the diffusio...

Страница 16: ...nguage When the language is displayed press the POWER button to continue with the start up sequence ClO2 Cell Reminder Screen After the Battery Status screen appears during the start up of the instrum...

Страница 17: ...SELECT switch arrow down At any time during the operation of the unit or during the stabilization period you can enter the menu to change the Quick Select mode by pressing the SELECT switch arrow down...

Страница 18: ...e to add liquid to within 1 8 inch from the bottom of fill hole Warning Do not over fill reservoir Trapped air must be allowed to escape through vent plug as fill screw is replaced Contact the factory...

Страница 19: ...n blown contact the factory Flow too low Flow too high accompanied by an audible beep Accurate air flow is critical to an accurate gas mixture The microprocessor and built in precision mass flow senso...

Страница 20: ...sor detects an abnormally high cell voltage condition One possibility for this high voltage is that one of the pins may be making a faulty electrical connection Another possibility is that the electro...

Страница 21: ...t expenses incurred without our prior approval Advanced Calibration Designs Inc s obligation under this warranty shall be limited to repairing or replacing and returning any product which shall be ret...

Страница 22: ...r 50 hours of use 4 Hydrogen One year or 50 hours of use 5 Chlorine Dioxide One year 50 hours of use 100 Hour Generating Cells 1 Chlorine One year or 100 hours of use 2 Hydrogen Sulfide One year or 10...

Страница 23: ...e Chlorine Dioxide 1 Qty Refill 193 0101 05 Electrolyte Chlorine Dioxide 5 Qty Refill 193 0101 10 Electrolyte Chlorine Dioxide 10 Qty Refill 193 0101 25 Electrolyte Chlorine Dioxide 25 Qty Refill 193...

Страница 24: ...070 00 Hydrogen Cyanide Cell 50 hrs 510 2090 00 Hydrogen Cell 50 hrs 510 2090 20 Hydrogen Cell 100 hrs 715 0403 0X 3 Foot Hose w connector low flow 1 4 OD 715 0405 0X 5 Foot Hose w connector low flow...

Страница 25: ...urs Warm up time to 90 Approximately 5 minutes L x W x H 8 5 x 4 25 x 3 0 21 6 x 10 8 x 7 6 cm Weight 3 lbs 1360 g Operating Temperature 0 C to 50 C Relative Humidity intermittent use 0 100 Accuracy 1...

Страница 26: ...05USA Telephone 520 290 2855 Fax 520 290 2860 TollFree 800 737 0223 Email acd goACD com Web www goACD com P N 910 0603 00 AdvancedCalibrationDesigns Inc InstructionManual CalibrationGasGenerator Advan...