PB300_Li-Ionen_Kurzanleitung_PB300_Li-Ion_Brief_Overview_V1.00_de_en
44 / 47
24.1 No function while switching on
Possible cause
Remedial actions
Battery charge too low
Check battery charge, charge battery if necessary
Fuses tripped
Check fuses internally
24 V DC output plug disconnected
Check 24 V DC plug on the front
Load on the socket too high (for example laser
printer)
Check the power data of the load (for example laser
printer)
Comply with the maximum load according to the
technical data
PB300 Li-Ion has switched off automatically
– when
battery capacity is discharged to < 10 %
Charge PB300 Li-Ion. After the battery has
discharged down to automatic shut-off, it must be
charged up to > 15 %. It cannot be turned on again
until this level is reached.
Fault current circuit breaker (RCD) triggered
Check the fault current circuit breaker (RCD) on the
back and turn on.
24.2 No function while charging
Possible cause
Remedial actions
Fuses tripped
Check internal fuse on the battery
Charging cable/charger faulty
Have the charge cable and charger checked by
authorized personnel
25
Miscellaneous
EU Directive on the Disposal of Waste Electrical and
Electronic Equipment (WEEE, Waste Electrical and Electronic Equipment)
All components must be returned to the manufacturer at the end of their service life for
recycling.
WEEE: 53473276
26
EU Declaration of Conformity
ACD Elektronik GmbH hereby declares that the PB300 Li-Ion is in compliance with the
following Directives.
Niederspannungs-Richtlinie/EC Low Voltage Directive 2014/35/EU
EMV-Richtlinie/Electromagnetic Compatibility 2014/30/EU
RoHS-Richtlinie/RoHS Directive 2011/65/EU
The complete text of the EU Declaration of Conformity is available in the customer
portal at the following internet address: