INITIAL START-UP

INTRODUCTION

The  AccuTemp  STEAM’N’HOLD™ takes 
the time-proven method of cooking with 
steam and adds the advantage of control. 
This is accomplished by reducing the internal 
atmospheric pressure of the  cooking 
compartment, thereby lowering the temperature 
at which the water begins to boil. This allows 
the operator to control the temperature of 
the steam for cooking. Controlling the steam 
temperature gives the operator the ability to 
cook the food to the desired temperature 
without over-cooking, resulting in a more 
tender, juicier, nutritious product and with 
less shrinkage than was previously possible. 
Once the cooking time expires, the appliance 
automatically enters the “HOLD” mode. In this 
mode, the thermostat regulates the internal 
temperature. At this time, steam is no longer 
generated and the cooking compartment is held 
at the desired temperature at a relative humidity 
of 100%. This eliminates food from drying out 
by suppressing the evaporation of the products’ 
natural moisture. As a result, most food products 
can be held in a ready-to-serve state for several 
hours after cooking, with no appreciable loss in 
taste, appearance or consistency.

DAILY PREP-

Preparing the 

STEAM’N’HOLD™

 for use each day 

requires very little time and effort: simply fill the 
appliance with water and preheat.

CAUTION!

Before filling the cooking compartment with 
water, ensure that the drain valve on the front 
of the appliance is in the closed position. 
Ensure that a full size steam table pan or a 
1/1 gastronome pan with a minimum depth 
of 4 inches, has been positioned on the pan 
rail brackets under the appliance. Although 
the mineral content of the water is not that 
important, the appliance should always be 
drained and cleaned at the end of each day to 
prevent food or mineral buildup. 

Figure 4

 

̆

At the beginning of each day, open the 

door of the appliance and pour 3 gallons (11 
liters) of ordinary tap water into the bottom 
of the cooking compartment. Daily water 
usage will depend on several factors: cooking 
temperature, the products being cooked and 
the length of time the door is open. In most 
cases, 3 gallons (11 liters) of water will last 
several hours or more. If the appliance does run 
out of water, the “Low Water” warning indicator 
light and buzzer will turn on. Should this occur, 
simply turn the appliance off, refill it with water 
and restart the appliance. If the shutdown 
occurred during cooking, the cycle will resume 
at the point it stopped. Time adjustment may 
be necessary, depending on the temperature of 
the water the appliance was re-filled with.

INITIAL START-UP-CONT.

DRAIN OPEN

DRAIN CLOSED

Содержание STEAM'N'HOLD

Страница 1: ...2207 INSTALLATION OPERATOR MANUAL S N 35389 HIGHER AccuTemp Products INC 11919 John Adams Dr New Haven IN 46774 www accutemp net AccuTemp product may be covered by one or more US Patents See www accutempip net ...

Страница 2: ... OF CONTENTS PAGE 2 SAFETY WARNINGS PAGE 3 WARRANTY PAGE 4 CONTROL COMPONENT IDENTIFICATION PAGE 5 INSTALLATION PAGE 6 OPERATION PAGE 9 TROUBLESHOOTING PAGE 14 SERVICE PAGE 15 CURRENT REVISION DATE PRIOR REVISION DATE CHANGE 2207 07 05 2022 2105 05 14 2021 Updated Logo ...

Страница 3: ...rating instructions and safety instructions 2 Use caution when operating the steamer as direct contact with steam can result in severe burns 3 Please use caution when emptying the appliance drain pan as the contents of the pan could cause severe burns 4 Keep the floor in front of the appliance clean and dry 5 Do not use pressurized water to clean the appliance 6 Use of replacement parts other than...

Страница 4: ...advance approval from AccuTemp factory service to perform the repair or replacement This warranty includes travel time not to exceed two hours and mileage not to exceed 50 miles 100 miles round trip but does not include post start up assistance or training tightening of loose fittings or external electrical connections minor adjustments maintenance gaskets or cleaning AccuTemp will not reimburse t...

Страница 5: ...TTON LOW TEMPERATURE STEAM HOLD THERMOSTAT TIMER VACUUM GAUGE TEMPERATURE GAUGE STATUS AND FAULT ALARMS INDICTORS OPERATIONAL INSTRUCTIONS DOOR LATCH DRAIN PAN NOT SUPPLIED MUST BE INSTALLED DURING COOKING AND DRAINING OPERATIONS ADJUSTABLE FOOT CONTROLS AND HARDWARE LOCATIONS ARE THE SAME FOR THE S3 AND S6 MODELS FIG 1 CUSTOMER SUPPLIED DRAIN PAN ...

Страница 6: ...e Once the rubber foot tips have been installed rotate the foot adjusters up or down as needed to level the appliance side to side and front to back SINGLE STAND INSTALLATION WITH ADJUSTABLE FEET The AccuTemp SNH10 single stand is equipped with adjustable height feet and the AccuTemp SNH11 single stand is equipped with non The AccuTemp SNH10 single stand is equipped with adjustable height feet and...

Страница 7: ...onsignee in collecting claims which has been properly managed and actively pursued AccuTemp can t file any damage claims or assume responsibility or accept any reductions in payment for any claims DOUBLE STAND INSTALLATION WITH ADJUSTABLE FEET WARNING When using a stand that is equipped with casters the floor surface must be level and flat Failure to do so can result in a tipping hazard that could...

Страница 8: ... plate located on the left side access panel of the appliance This appliance should never be connected to a circuit operating at more than 150 VAC to ground and should always be connected to an individual branch circuit Make sure the voltage at the supply receptacle is within 10 of the voltage listed on the appliance data plate Connection to any other voltage may permanently damage your STEAM N HO...

Страница 9: ...the STEAM N HOLD for use each day requires very little time and effort simply fill the appliance with water and preheat CAUTION Before filling the cooking compartment with water ensure that the drain valve on the front of the appliance is in the closed position Ensure that a full size steam table pan or a 1 1 gastronome pan with a minimum depth of 4 inches has been positioned on the pan rail brack...

Страница 10: ... pump operating The appliance will start to fill with water via a water fill port located in the rear lower left corner The thermostat will be turned off for the initial fill to prevent damage to the heater elements The cooking compartment water reservoir will continue to fill with water until the both water probes sense that the water level is correct The heater is then turned on and normal opera...

Страница 11: ...nob is needed to turn off the buzzer The Hold temperature is determined by the thermostat setting It is recommended to preheat the cooking compartment to the desired holding temperature if the cooking compartment is in a cool state To hold food independently of cooking rotate the timer counter clockwise until the white indicator on the timer knob lines up with the yellow HOLD position Select the d...

Страница 12: ...and operate for 15 minutes at the maximum temperature in the T STAT mode 200ºF 93ºC or set the Switch to the FAST COOK position 212ºF 100ºC Sea Level 3 Allow the water and vinegar mixture to cool Ensure that a full size steam table pan or a 1 1 gastronome pan with a minimum depth of 4 inches 101 mm has been placed beneath the appliance Use caution while opening the drain valve Empty the water into...

Страница 13: ...MP4011 2207 STEAM N HOLD 13 REMOVABLE PAN RAILS STEAM DIRECTOR CONNECTED MODELS ONLY COOKING COMPARTMENT FIG 5 1 FIG 5 2 WATER SENSORS OVERFILL FLOAT BALL FIG 5 3 ...

Страница 14: ...eamer and or pans if possible Make sure the water drain valve on the front of the Steam N Hold is tightly closed The steamer may appear to be cooking normally if the valve is slightly open but efficiency may be compromised Check the door seal for food debris Food debris on the face of the door seal or under flap may cause steamer to appear to be cooking BASIC TROUBLESHOOTING normally but efficienc...

Страница 15: ...rtment GENERAL SERVICE INFORMATION WARNING AccuTemp Technical Services must be called for all warranty repair requests Service must be performed only by AccuTemp Products Inc preferred service agents Service performed by non preferred service agents will void all warranties Call AccuTemp Products Inc Technical Service Hot line at 800 480 0415 or 260 469 3040 or email us at service accutemp net for...

Отзывы: