BUILDING CODES AND STANDARDS

The appliance must be installed in accordance 
with the following building codes:
USA: National Electric Code, ANSI/NFPA-70, state 
and local codes. International Plumbing Code 
2003, ICC or Uniform Plumbing Code 2003, 
IAMPO. Canada: Canadian Electric Code, CSA 
C22.2 and state and local codes.

LOCATION AND PLACEMENT

To insure maximum benefit of your warranty; 
location, placement and leveling are critical. 
The AccuTemp STEAM’N’HOLD™ is designed for 
installation on either a commercial kitchen coun-
ter top or an AccuTemp STEAM’N’HOLD™ stand. 
Your appliance is equipped with vents to allow 
the proper ventilation of air through the electrical 
compartment. The vents are located on the bot-
tom and rear panel. To ensure these vents work 
properly a minimum 3” (77 mm) clearance from 
these vents must be allocated. It is also recom-
mended that the appliance not be placed under 
other wet equipment or locations. If located next 
to heat producing appliances additional clear-
ance could be required. 

LEVELING

This appliance must be installed in a level 
condition. An out-of-level condition may cause 
improper operation and possible damage. 
Damage caused by improper leveling is not 
covered by warranty. Use a spirit level, resting 
on the top of the appliance cabinet surface, to 
ensure it is level front-to-back and left-to-right.

COUNTER-TOP INSTALLATION

 If this is a counter-top installation, be sure to 
install the rubber foot tips provided with your 
appliance onto each foot adjuster of each of the 
leg. This will keep the appliance from sliding on 
the counter-top under normal use. Once the 
rubber foot tips have been installed, rotate the 
foot adjusters up or down as needed to level the 
appliance side to side and front to back.

SINGLE STAND INSTALLATION WITH 
ADJUSTABLE FEET

The AccuTemp SNH10 single stand is equipped 
with adjustable height feet and the AccuTemp 
SNH11 single stand is equipped with non-

The AccuTemp SNH10 single stand is 
equipped with adjustable height feet and the 
AccuTemp SNH11 single stand is equipped 
with non-adjustable height casters. Both 
can be used with either a single S3 or S6 
model STEAM’N’HOLD™. Before mounting 
the appliance on the SNH11 stand, engage 
the brakes on the two front locking casters, 
pressing on the “ON” handle of the brake 
mechanism. To mount the appliance, carefully 
lift and place it on the horizontal mounting 
brackets, ensuring that the (4) mounting holes 
on the underside of the appliance is lined up 
with the mounting holes on the brackets. Then, 
using a 7/16” wrench, fasten one pair of the ¼”-
20 hex bolts and ¼” split lock washers through 
the underside of each stand bracket mounting 
hole into the appliance and tighten securely. 
With the SNH10 stand, level the appliance by 
adjusting the feet found at the ends of each 
stand leg, either up or down as needed.

INSTALLATION

SINGLE STAND INSTALLATION WITH CASTERS

Before mounting the appliance 

on the SNH11 

stand, engage the brakes on the two front 
locking casters, pressing on the “ON” 
handle of the brake mechanism. To mount 
the appliance, carefully lift and place it 
on the horizontal mounting brackets, 
ensuring that the (4) mounting holes on 
the underside of the appliance are lined up 
with the mounting holes on the brackets. 
Then, using a 7/16” wrench, fasten one 
pair of the ¼”-20 hex bolts and ¼” split 
lock washers through the underside of 
each stand bracket mounting hole into the 
appliance

 

and tighten securely. 

Содержание STEAM'N'HOLD

Страница 1: ...2207 INSTALLATION OPERATOR MANUAL S N 35389 HIGHER AccuTemp Products INC 11919 John Adams Dr New Haven IN 46774 www accutemp net AccuTemp product may be covered by one or more US Patents See www accutempip net ...

Страница 2: ... OF CONTENTS PAGE 2 SAFETY WARNINGS PAGE 3 WARRANTY PAGE 4 CONTROL COMPONENT IDENTIFICATION PAGE 5 INSTALLATION PAGE 6 OPERATION PAGE 9 TROUBLESHOOTING PAGE 14 SERVICE PAGE 15 CURRENT REVISION DATE PRIOR REVISION DATE CHANGE 2207 07 05 2022 2105 05 14 2021 Updated Logo ...

Страница 3: ...rating instructions and safety instructions 2 Use caution when operating the steamer as direct contact with steam can result in severe burns 3 Please use caution when emptying the appliance drain pan as the contents of the pan could cause severe burns 4 Keep the floor in front of the appliance clean and dry 5 Do not use pressurized water to clean the appliance 6 Use of replacement parts other than...

Страница 4: ...advance approval from AccuTemp factory service to perform the repair or replacement This warranty includes travel time not to exceed two hours and mileage not to exceed 50 miles 100 miles round trip but does not include post start up assistance or training tightening of loose fittings or external electrical connections minor adjustments maintenance gaskets or cleaning AccuTemp will not reimburse t...

Страница 5: ...TTON LOW TEMPERATURE STEAM HOLD THERMOSTAT TIMER VACUUM GAUGE TEMPERATURE GAUGE STATUS AND FAULT ALARMS INDICTORS OPERATIONAL INSTRUCTIONS DOOR LATCH DRAIN PAN NOT SUPPLIED MUST BE INSTALLED DURING COOKING AND DRAINING OPERATIONS ADJUSTABLE FOOT CONTROLS AND HARDWARE LOCATIONS ARE THE SAME FOR THE S3 AND S6 MODELS FIG 1 CUSTOMER SUPPLIED DRAIN PAN ...

Страница 6: ...e Once the rubber foot tips have been installed rotate the foot adjusters up or down as needed to level the appliance side to side and front to back SINGLE STAND INSTALLATION WITH ADJUSTABLE FEET The AccuTemp SNH10 single stand is equipped with adjustable height feet and the AccuTemp SNH11 single stand is equipped with non The AccuTemp SNH10 single stand is equipped with adjustable height feet and...

Страница 7: ...onsignee in collecting claims which has been properly managed and actively pursued AccuTemp can t file any damage claims or assume responsibility or accept any reductions in payment for any claims DOUBLE STAND INSTALLATION WITH ADJUSTABLE FEET WARNING When using a stand that is equipped with casters the floor surface must be level and flat Failure to do so can result in a tipping hazard that could...

Страница 8: ... plate located on the left side access panel of the appliance This appliance should never be connected to a circuit operating at more than 150 VAC to ground and should always be connected to an individual branch circuit Make sure the voltage at the supply receptacle is within 10 of the voltage listed on the appliance data plate Connection to any other voltage may permanently damage your STEAM N HO...

Страница 9: ...the STEAM N HOLD for use each day requires very little time and effort simply fill the appliance with water and preheat CAUTION Before filling the cooking compartment with water ensure that the drain valve on the front of the appliance is in the closed position Ensure that a full size steam table pan or a 1 1 gastronome pan with a minimum depth of 4 inches has been positioned on the pan rail brack...

Страница 10: ... pump operating The appliance will start to fill with water via a water fill port located in the rear lower left corner The thermostat will be turned off for the initial fill to prevent damage to the heater elements The cooking compartment water reservoir will continue to fill with water until the both water probes sense that the water level is correct The heater is then turned on and normal opera...

Страница 11: ...nob is needed to turn off the buzzer The Hold temperature is determined by the thermostat setting It is recommended to preheat the cooking compartment to the desired holding temperature if the cooking compartment is in a cool state To hold food independently of cooking rotate the timer counter clockwise until the white indicator on the timer knob lines up with the yellow HOLD position Select the d...

Страница 12: ...and operate for 15 minutes at the maximum temperature in the T STAT mode 200ºF 93ºC or set the Switch to the FAST COOK position 212ºF 100ºC Sea Level 3 Allow the water and vinegar mixture to cool Ensure that a full size steam table pan or a 1 1 gastronome pan with a minimum depth of 4 inches 101 mm has been placed beneath the appliance Use caution while opening the drain valve Empty the water into...

Страница 13: ...MP4011 2207 STEAM N HOLD 13 REMOVABLE PAN RAILS STEAM DIRECTOR CONNECTED MODELS ONLY COOKING COMPARTMENT FIG 5 1 FIG 5 2 WATER SENSORS OVERFILL FLOAT BALL FIG 5 3 ...

Страница 14: ...eamer and or pans if possible Make sure the water drain valve on the front of the Steam N Hold is tightly closed The steamer may appear to be cooking normally if the valve is slightly open but efficiency may be compromised Check the door seal for food debris Food debris on the face of the door seal or under flap may cause steamer to appear to be cooking BASIC TROUBLESHOOTING normally but efficienc...

Страница 15: ...rtment GENERAL SERVICE INFORMATION WARNING AccuTemp Technical Services must be called for all warranty repair requests Service must be performed only by AccuTemp Products Inc preferred service agents Service performed by non preferred service agents will void all warranties Call AccuTemp Products Inc Technical Service Hot line at 800 480 0415 or 260 469 3040 or email us at service accutemp net for...

Отзывы: