Section III:  Service and Maintenance

new controller and secure to front panel with mounting 

nut and replace knob securing with setscrew.
7.Replace control console panel and secure in place.
8.  If replacing the sensor (probe) (Item 2),drain water in 

jacket below the sensor location.
9.  Refer to step 4 to disconnect leads from primary con-

trol thermostat controller. 
9.  Remove sensor (Item 2) from kettle jacket using a 

18mm deep well socket.
10. After installing new sensor, reconnect the wires from 

the new sensor (probe) to the controller.  
11. Replace control console panel and secure in place.

12. Refill kettle with pure distilled water.  Refer to Fill-

ing Steam Jacket of this section for instructions.

B) Replacing the Ignition System Control

Disconnect power and turn off main gas supply before 

starting.
To replace the gas control valve (Item 4); 
1.Disconnect the controls connector and the igniter 

connector from the gas control valve (Item 4).

2. Disconnect the pilot tube (Item 3) from the gas control 

valve (Item 4).
3. Loosen flexible gas hose nut (Item 7), using a crescent 

wrench or 1 1/8 open end wrench, located under the 

control console.
4. Remove the manual gas valve, reducing bushing and 

nipple from gas control valve  
5.Remove 1/4-20 bolts (Item 6) from rear of control 

console to loosen bracket holding gas valve.
6.Remove gas control valve from control console.  
Note:  You may need to rotate valve slightly to allow 

clearance for elbows  and bracket attached to valve.  
Make note of positioning of valve in control console when 

removing to insure correct placement of new valve.
7.Reverse steps to secure new gas control valve in place.

12

Содержание EDGE ALTLGB

Страница 1: ...THORIZED SERVICE AGENT EVACUATE ALL PERSONNEL FROM THE AREA WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION O...

Страница 2: ...bly 13 Actuator Maintenance Adjustment 14 Actuator Tension Adjustment 14 Actuator Repacking with Grease 14 Actuator Replacement 14 Fig 3 1 Actuator Components Assembly 15 Fig 3 2 Removing Installing A...

Страница 3: ...for safe delivery to the customer until customer acceptance of the package Careful inspection of the packaging and the appliance should be completed before acceptance from the transportation company C...

Страница 4: ...de cet appareil ou de tout autre appareil Always disconnect from the power supply and close the main gas valve before servicing The ignition system controls of this equipment have been factory set for...

Страница 5: ...a power failure This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do...

Страница 6: ...restrict air movement into the equipment s combustion area or prevent proper combustion Adequate clearance for servicing and proper operation must be maintained Warning This unit is not suitable for...

Страница 7: ...sed Connect the supply line to the ball valve at the rear of the unit Tighten the connection securely Electrical Connection A power cord is provided on the back of the unit for connecting to the elect...

Страница 8: ...l Inlet Pressure Range Factory Set Nominal Out let Pressure Adjustment Setting Range Intermittent Pilot Natural 5 0 7 0 w c 3 5 w c 3 5 LP 12 0 14 0 w c 9 0 w c 8 12 Checking For Gas Leaks WARNING Do...

Страница 9: ...main burner and shut off the gas supply before disconnecting the manometer or pressure gauge by reversing the procedure in Step 2 in the previous procedure for checking the inlet pressure 5 Replace th...

Страница 10: ...tact with any electrical and control components For routine cleaning Accutemp s optional Care Kit accessories help you thoroughly clean all surfaces including the inside of the lid and the inside of t...

Страница 11: ...mostat Dial Temperature Allows the user to set the cooking temperature of the unit Unit Power On Indicator Light Green Illuminates upon depressing the rocker switch to the ON position This indicates t...

Страница 12: ...knob to the ON position and set the primary thermostat dial to the desired temperature setting How to Start Cooking 1 Press the rocker switch to ON position turn the primary thermostat clockwise to th...

Страница 13: ...ut breaking the seal and returned to Accutemp The warranty is voided if the seal is broken or any attempt is made to recalibrate a thermostat See below for replacement instructions 1 Disconnect the un...

Страница 14: ...ition System Control Disconnect power and turn off main gas supply before starting To replace the gas control valve Item 4 1 Disconnect the controls connector and the igniter connector from the gas co...

Страница 15: ...r of burner assembly Item 9 Lift burner out of shroud Reverse steps to replace new burner D Replacing the Pilot Igniter Assembly Refer to steps in C Replacing the Gas Burner or Burner Orifices then Tu...

Страница 16: ...ly later 5 Grasp the actuator sleeve and pull down away from the actuator rod The components inside the actuator sleeve will slide out 6 Pack the spring or springs with Bel Ray No Tox Clear Grease 2 T...

Страница 17: ...COVER STOP 456695 1 8 Parts List TITLE PART NUMBER QTY ITEM SLEEVE WELDMENT 404483 001 1 1 ROD ACTUATOR LUG 455879 1 2 WASHER NYLON 1 355 X 52 408505 3 3 NYLON SHOULDER WASHER 408506 2 4 NUT SS LOCK 1...

Страница 18: ...ilot gas control system The systems is as follows The SV9501 9502 SmartValve System Control combines gas flow control and electronic intermittent pilot sequencing functions into a single unit The Q345...

Страница 19: ...sidual steam contained in the steam jacket Remove sight glass and place a funnel in the inlet elbow Pour water into funnel Continue adding water until the Fig 3 5 Examples of Problem Pilot Flames C Id...

Страница 20: ...lain end that is not threaded is constructed of a material suitable for exposure to temperatures of 375 F or greater is of a pipe size equal to or greater than that of the valve outlet over its entire...

Страница 21: ...er such as Klenzade XY 12 d Film remover such as Klenzade LC 30 Procedure 1 Clean food contact surfaces as soon as possible after use If the unit is in continuous use thoroughly clean and sanitize the...

Страница 22: ...se off the sanitizer thoroughly 9 It is recommended that each piece of equipment be sanitized just before use 10 If there is difficulty removing mineral deposits or a film left behind by hard water or...

Страница 23: ...stat setting too low Primary thermostat malfunc tioning Air in kettle jacket Uneven cooking due to cold spots Low gas pressure Plugged orifice s in burner Plugged burner supply tube Pilot Outages Low...

Страница 24: ...on Pilot burner lights No Measure voltage to SV9500 Voltage must be at least 19 5 VAC No Check transformer line volt supply Yes Yes Main valve opens No Replace igniter sensor assembly and retain Rest...

Страница 25: ...CP 1 8 npt 440280 Pigtail anti siphon SS 1 4 npt 456724 Safety relief valve 30 psi 425 lbs hr 3 4 npt Replaces part 440168 456727 Pressure gauge 30Hg 0 60 Replaces part 406732 406578 Terminal Block Ju...

Страница 26: ...Section VI Parts List Actuator Parts List Assembly Fig 6 1 Actuator Assembly Diagram 24...

Страница 27: ...2 3 1 Nut handle 408392 408392 408207 2 Handle round stainless steel 408359 408359 2 408360 3 Hex bonnet nut 450033 01 450032 01 440234 01 4 Faucet gland 460097 01 410228 01 440233 01 5 O ring 400382...

Страница 28: ...ply with these codes Installation 1 Positioning the Unit 3 Verify the voltage requirements and electrical connections were checked Installation 3 Electrical Connection 4 Verify that a sediment trap an...

Страница 29: ...the Continental United States and Hawaii They are available 7 days a week from 7 00 a m through 7 00 p m Eastern Standard Time Model No Purchased From Serial No Date Purchased Purchase Order No Locati...

Страница 30: ...Wiring Diagram 120V 1PH 28...

Страница 31: ...Wiring Diagram 240V 1PH 29...

Страница 32: ...RELAY FOR 240 V RED LEAD TO RELAY FOR 208 V BLACK LEAD TO RELAY FOR 120 V TRANSFORMER 24 VOLT YELLOW 24 VAC BLUE 24 VAC BLACK BLACK ORANGE Honeywell 25V GND DIRECT SPARK IGNITION 25V BURNER VALVE VALV...

Страница 33: ...rm the repair or replacement This warranty includes travel time not to exceed two hours and mileage not to exceed 50 miles 100 miles round trip but does not include post start up assistance or trainin...

Страница 34: ...IMPORTANT SERVICE INFORMATION AccuTemp Product Inc Technical Customer Support Technician is available Monday thru Sunday 7 00am to 7 00pm EST...

Отзывы: