13084 ON/OFF VALVE & CUTTING HEAD MANUAL
4.8
Troubleshooting
Cutting Head
Problem Solution
Not flushing thoroughly when changing orifice
Bad water quality
Orifices do not last at least 20 hours
Blown in-line filter upstream
In the A2 head rotate nozzle 120
°
every shift or 8 hours
Using too much abrasive.
Nozzle Life too short or not wearing
round
Running with worn orifice.
Vacuum leak, check inlet tube connection
Abrasive not drawing into head
properly
Smaller combinations such as .007/.020 may need to have
the nozzle lowered about ¼” to induce more vacuum
Can’t unplug nozzle
Put nozzle upside down in head and cycle jet on/off
Leak Points (Causes and Solutions)
Item Problem
Solution
1
Seal Weep hole.
Replace Valve
Seal kit.
2
Inlet Weep hole.
Tighten inlet
fitting.
3
Leakage at bottom
of valve body.
Tighten adapter to
valve body or
tighten inlet fitting
in collar.
4
Head Weep hole.
Tighten Head to
Adapter.
5
Dripping Nozzle
when valve closes.
Needle and Seat
are worn and need
new valve kit.