background image

Slide Installation

Install Cabinet Member

1. Separate the slide members by first actuating the manual 

override located on the locking mechanism. 

2. Then, lift the disconnect lever to release the inner (drawer) 

member.

3. Overlay drawer front: 

- Conventional mounting, see Figure 1. 

- 32 mm system mounting, see Figure 2.

Conventional mounting - Cabinet

System Holes

2.0 mm

38.1

mm

Min.

For overlay

drawer front

37.0 mm

Cabinet 

Member

32 mm system mounting - Cabinet

Figure 2. 

Cabinet Member

1 7/8"

Min. 1 1/2"

Drawer

For overlay

drawer front

IMpORTANT:

 

•  Be sure the interior cabinet depth allows for an additional 3" 

beyond the length of the slide to provide room for the locking 

mechanism and wiring. See the chart below for minimum cabinet 

depth. For the inset drawers, be sure to  

provide sufficient cabinet depth to allow for the slide setback.

Slide Length

Min. Cabinet Depth

16"

19"

18"

21"

20"

23"

22"

25"

•  Slides will not function properly if side space is less than .50" 

[12.7 mm]. For optimum performance, construct drawer 1-1/16" 

[27.0 mm] smaller than the opening of the cabinet.

Installation Instructions

2

WARNING!

 Before installing the drawer, insure 

you have access to the lock’s manual override 

lever or the activation device must be connected 

and working properly. 

Otherwise, you will not be 

able to unlock the slide and open the drawer.

Figure 1. 

4. Inset drawer front: 

Slide setback is the thickness of the drawer front plus 1/8"  

[3.2 mm].

5. Use only the 32 mm system holes or the wood screw holes 

located at the tip of the breathing tabs. Do not use any other 

holes on the cabinet member for mounting (Figure 3).

Install Drawer Member

1. See Figure 4 for drawer member setback.
2. Install the drawer member with a screw through the cam adjuster 

and a screw through a hole or slot at the rear (see Figure 4).

Use all mounting tabs to achieve load rating.

Figure 3. 

No

Yes

Manual Override

Cabinet Member Fastener Locations

Refer to Senseon plus Installation Guide  

for complete system instructions.

11/16" [17.8]

Drawer Member Setback

Flush for conventional mounting

2mm (+1.0/-0.0) for 32mm system mounting

Cam Adjustment

1/4" [6.4]

1 1/4" [31.8]

Figure 4. Conventional Mounting and 32 mm Mounting - Drawer

Drawer Insertion and Adjustment

WARNING!

 Before installing the drawer, you must 

have access to the lock’s manual override lever 

or the activation device must be connected and 

working properly. Otherwise, you will not be able to 

unlock the slide and open the drawer.

1. Make sure the ball bearing retainers in the cabinet are fully 

forward. Install drawer into cabinet and close the drawer.

2. Install additional screws to secure the drawer-member after 

verifying form and function install.

Отзывы: