Manual Part # 800-1342-001 Rev 112012
Page 11 of 12
Battery Replacement
Periodically, the coin cell battery in the SPC Transmitter will require
replacement. A low battery condition is detected by the Transmitter and will be
indicated by flashing the
LOW BAT
LED when a position message is sent. A
low battery condition still allows normal operation but the transmission range
may be diminished. Change the battery as soon as possible by completing the
following:
1. Unplug the SPC Transmitter from the side of the ProScale DRO.
2. Using a Phillips screwdriver, remove the two screws from the back of
the housing.
3. Touch a grounded metal surface to discharge any static electricity from
your body, and then remove the back cover of the Transmitter
enclosure.
4. Slide out the coin cell battery from the battery holder.
5. Install a new CR2450 (or equivalent) lithium battery into the battery
holder with the
+
PLUS
side
UP
. When the battery is installed, the two
LEDs on the front of the Transmitter will both flash momentarily.
NOTE: If the LEDs continue to flash on and off, remove the
battery for 10 seconds and then re-install it.
6. Re-install the rear enclosure cover and replace the screws.
7.
Plug the SPC Transmitter into the DRO’s SPC data port, ensuring the
pins are correctly aligned.