94MS42 Rev.B1 S/W Ver 2.06
9-3
Work Lights
Note:
The work lights are controlled by a rocker switch on the underside
of the right front corner of the nose cover.
Note:
If the work lights are not turning ON, check the rocker switch
and power to the switch.
Note:
The work lights receive their power from the autoformer in the
nose section
•
To change the lamps the trays must first be moved to the center position.
This is done by:
•
Press and hold the
S
button.
•
Press the
G
button.
•
Release both buttons when trays start moving.
•
Just before the trays reach the center turn the power OFF.
•
Lift the diffusion cover off of the light assembly.
•
Twist the lamp to disengage it from the socket and remove it.
•
Install in reverse order.
Nose Fans
Note:
The nose fans are controlled by a rocker switch on the underside
of the right front corner of the rail cover.
Note:
If the nose fans are not turning ON, check the rocker switch and
power to the switch.
•
Remove the nose.
•
Disconnect the power leads to the blower(s).
•
Remove the blower(s).
•
Install in reverse order.
Cleaning or Replacing Nose Filters
•
Slide the filters toward the front of the unit and out of the brackets.
•
Clean metal filters with water or environmentally safe solvent.
Содержание AP42CL 8000
Страница 1: ...P P AP42CL 8000 Closed Loop High Resolution Printer Service Manual 94MS42 Rev B1 S W 2 06 O ...
Страница 12: ...1 6 94MS42 Rev B1 S W Ver 2 06 ...
Страница 20: ...2 8 94MS42 Rev B1 S W Ver 2 06 ...
Страница 56: ...8 8 94MS42 Rev B1 S W Ver 2 06 ...
Страница 84: ...12 6 94MS42 Rev B1 S W Ver 2 06 ...
Страница 114: ...13 28 94MS42 Rev B1 S W Ver 2 06 ...
Страница 124: ...15 4 94MS42 Rev B1 S W Ver 2 06 ...
Страница 134: ...O Corporation 17112 Armstrong Avenue Irvine Ca U S A 92614 U S A 949 399 6500 Fax 949 399 6501 ...