background image

10 

 

 

TROUBLESHOOTING: 

 
If your device is not operating properly, please check below for common problems and suggested solutions: 

 

1. 

No power source; no display in LCD: 

 

Check if the battery is low and needs to be recharged. 

 

If the unit was previously used, switch the power to OFF first, then back to ON. 

 

2. 

Stimulation is weak or nonexistent: 

 

Check that the electrode pads are firmly attached to skin. 

 

Check that the electrode pads are not touching each other. 

 

Check that electrode pad are not stacked together or overlap. 

 

Check that the cord is properly connected to the unit. 

 

Check if the battery is low and needs to be recharged. 

 

The intensity level is very low.  

 

Both pads from the same wire must be attached to one person’s body to feel sensation. 

 

3. 

Electrode pads are not sticky: 

 

The electrode pads lost their adhesiveness and need to be replaced. 

 

Wash adhesive surface of pads softly with your fingertips for about 3 seconds under slow running water. 

 

Make sure you are not perspiring and are in a cool room when using.  

 

If electrode pads were applied immediately after washing, make sure to dry the pad before applying.  

 

If the electrode pads were exposed to high temperature, high humidity, or direct sunlight, the electrode pads may have 
been ruined.  

 

4. 

The skin turns red or the skin feels irritated: 

 

The therapy time is too long or the intensity is set too high.  

 

The adhesive surface of pads is dirty or dry and must be washed.  

 

If problem persists, stop using device and contact your physician. 

 

5. 

One pad feels stronger than the other: 

 

This is normal. Different areas of your body will react differently. 

 

Make sure the pads are sticky and are making good contact. 

 

6. 

Power cut off during use: 

 

Check if battery is low and charge if necessary. 

 

Check that cord is intact and is not broken.  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание AP212

Страница 1: ...USER MANUAL AccuMed AP212 Mini Electronic Pulse Stimulator AP212 USER MANUAL V2 0 1 Revised March 10 2017 www AccuMed com ...

Страница 2: ... OF CONTENTS INTRODUCTION 3 SAFETY WARNINGS 3 SPECIFICATIONS AND ESSENTIAL PERFORMANCE 4 FEATURES 5 INTENDED USE 5 DEVICE OVERVIEW 5 TWO KEY POINTS FOR OPERATIONS 6 RECOMMENDED PRACTICES 7 READJUSTMENTS ALTERATIONS AND REPAIRS 8 CLEANING AND MAINTENANCE 9 TROUBLESHOOTING 10 RECOMMENDED PLACEMENT AREAS 11 ...

Страница 3: ...r abnormal blood pressure lack of skin sensation or an abnormal skin condition any condition requiring the active supervision of a physician Do not use this device while driving Do not use this device while sleeping Do not use this device in high humidity areas such as a bathroom Keep the device away from moisture high temperatures and direct sunlight Keep this device out of reach of children Stop...

Страница 4: ...ouch the USB port when using the device The USB port is only used to connect the charger Do not connect other devices 3 The charger supplied by the manufacturer must in compliance with IEC EN 60601 1 the use of unauthorized chargers can impair the safety or damage the device 4 The battery needs to be charged for up to 10 hours before the first use 5 Only charge the unit when battery is completely ...

Страница 5: ...in the shoulders waist neck back arms and legs due to strain from exercise or normal household and work activities DEVICE OVERVIEW Self adhesive electrodes 510 k cleared Battery charger 800mm 30 5 long USB cable 1500mm 59 long Electrode cable INCLUDED IN THIS PACKAGE 1 Controller 2 Pairs of electrodes 510 k cleared 2 Output electrode cables 1 USB cable 1 Charger 1 User s manual 1 Plastic holder ...

Страница 6: ...lashes on the screen which indicates the channel you are in 2 Press the button to increase the intensity 3 Press the button to decrease the intensity CHANGE MODES 1 The device will automatically enter Mode 1 Variation I when turned on Press the Play Pause button to access the next variation in the main illustrated mode 2 Press the Play Pause button to access the next variation within the same mode...

Страница 7: ...ensitive areas or people with sensitivity to pulse sensations like pulling on your ear lobe NOTE Start from the lowest intensity and then gradually adjust to a comfortable level on a scale from 1 to 10 RECOMMENDED PRACTICES 1 Start by using it 1 2 times per day for each treatment area for 10 to 20 minutes 2 Be sure the treatment site is clean of dirt body oil and other cosmetics 3 The lifespan of ...

Страница 8: ...ou feel unusual discomfort stop using the device immediately Many people experience immediate relief from muscle pain while others require several days of regular use to feel the benefits The results vary and will depend upon your underlying conditions and how often you use the device If your pain does not improve you can try to increase the intensity and time or change the mode ELECTRODE PADS GUI...

Страница 9: ...ing to your local regulations B FOR ELECTRODE PADS 1 Unplug the output cord from the output jack of the controller after each use Cover both pads with the protective film before storing Never fold the electrode pads 2 Between uses store the electrodes in the reusable bag in a shady place Stock room temperature 5 C 27 C 41 80 F and humidity of 30 80 No need to sterilize 3 Never apply the pads to an...

Страница 10: ...de pads lost their adhesiveness and need to be replaced Wash adhesive surface of pads softly with your fingertips for about 3 seconds under slow running water Make sure you are not perspiring and are in a cool room when using If electrode pads were applied immediately after washing make sure to dry the pad before applying If the electrode pads were exposed to high temperature high humidity or dire...

Страница 11: ...ders Keep the area warm Avoid sudden movements with the aching shoulders Gentle movements are advisable in the initial stage and full motions at a later stage Pain in Back Mode 1 for 10 20 minutes and Mode 5 or 6 for 10 20 minutes twice or 3 times a day Apply the electrodes to the pain area Avoid working in the same position in the initial phase and change the position at times Pain in Waist Figur...

Страница 12: ...20 minutes Mode 6 for 10 20 minutes and Mode 3 for 10 20 minutes twice or 3 times a day The device can stimulate areas of the legs and thighs so as to improve the muscles Abdomen Mode 1 for 10 20 minutes Mode 2 for 10 20 minutes and Mode 6 for 10 20 minutes twice or 3 times a day Persistent and consistent use can help to improve the abdomen muscles Waist Mode 2 for 10 20 minutes Mode 3 for 10 20 m...

Страница 13: ...E The images below are mere suggestions on where to place the electrodes but only after the user has gone through the starting procedure this entire user manual and is familiar with the device Targeted muscle ...

Страница 14: ...14 ...

Страница 15: ...ase visit www AccuMed com Manufactured for AccuMed Biotech 16727 Park Row Drive Houston TX 77084 713 904 1955 Model AP212 Input DC 3 7V Weight 110g Size 83 42 9mm AP212 Use Only apply stimulation to normal intact clean skin Storage 20 55 C 93 humidity 50 106KPa Refer to User Manual before using Distributed by Amcrest Technologies LLC Notes Symbol Meaning Class II equipment Type BF applied part Ope...

Отзывы: