AM1730 Secondary Reference Platinum Resistance Thermometer

User’s Guide

4/10

2 Specifications

2.1 Specifications

Temperature Range

1730-12: -200°C to 420°C

1730-9: -60°C to 300°C

Resistance at 0 °C

Nominal 100 Ω

Temperature Coefficient

0.003925 Ω/ Ω/°C

Accuracy

±0.025°C at -196 °C

±0.015°C at 0.01 °C

±0.035°C at 420 °C

Drift

±0.01°C at 0 °C after 500 hours at 420 °C

Short Term Stability

±0.007°C

Thermal Shock

±0.005°C after 10 times thermal cycles from minimum to

maximum temperatures

Hysteresis

<=0.005°C

Self-heating

50 mW/°C

Response Time

9 seconds for 63% response to step change in water moving

at 3 feet per second

Measurement Current

0.5 mA or 1 mA

Sensor Length

32 mm

Sensor Location

5 mm from tip

Insulation Resistance

>1000 MΩ at room temperature

Sheath Material

Inconel

tm

Dimension

1730-12: 0.25 inch X  12 inch (6.35 mm X 305 mm)

1730-9: 0.187 inch X 9 inch (4.75 mm X 229 mm)

External Leads

Teflon

tm

–insulated copper wire, 4 leads, 2.5 meters

Handle Dimension

1730-12: 15mm (OD) x 65mm (L)

1730-9: 10mm (OD) X 50 mm (L)

Handle Temperature Range

-50°C to 180°C

Calibration Options

1730-12-T, PRT with NIST traceable calibration and data

1730-9-T, PRT with NIST traceable calibration and data

NVLAP - Accredited Calibrations available per request

Содержание AM1730

Страница 1: ...AM1730 Secondary Reference Platinum Resistance Thermometer User s Guide...

Страница 2: ...1 3 Calibrations 3 2 Specifications 4 2 1 Specifications 4 3 General Operations 5 3 1 Connecting to the readout device 5 3 2 Drive Current 5 3 3 Stability of Readings 5 3 4 Immersion Requirements 5 3...

Страница 3: ...ardous live component 5 Follow all other safety guidelines listed in this user s guide Cautions Follow these guidelines to avoid possible damage to the instrument 1 Avoid mechanical shocks DO NOT drop...

Страница 4: ...measure temperature or change of temperature It has wide applications for dry wells or temperature baths 1 2 Main Features High accuracy 0 015 C at 0 01 C Temperature range 200 C to 420 C Durable and...

Страница 5: ...Response Time 9 seconds for 63 response to step change in water moving at 3 feet per second Measurement Current 0 5 mA or 1 mA Sensor Length 32 mm Sensor Location 5 mm from tip Insulation Resistance...

Страница 6: ...wires can be distinguished by insulation colors Lead wire pairs attached to each end of the sensor are identified by red black and white blue insulation 3 2 Drive Current AccuMac recommends 1mA as dr...

Страница 7: ...ot submerge PRT handle when taking measurement 3 5 Thermal EMF Each AccuMac PRT has gone through an annealing process and stability test to minimize the thermal EMF which is caused by either impuritie...

Страница 8: ...ever possible b When shipping the PRT use protective box and other protective packaging materials to minimize mechanical shocks as much as possible c When using dry blocks make sure the well diameter...

Страница 9: ...repair service Be sure to have the model number and serial number of your PRT available 5 2 Problem Causes and Solutions a R0 Rtpw becomes higher significantly This is likely caused by mechanical shoc...

Страница 10: ...The warranty period begins on the date of the shipment Parts product repairs and services are warranted for 90 days The warranty extends only to the original buyer or end user customer of an AccuMac a...

Отзывы: