Appendix
Table 3 - Key Specifications
SPECIFICATIONS
Current Range
0.25A – 100000A
Range
50A, 200A, 500A, 2000A, 5000A rated input (field
configurable)
Output
0-1A
Nominal Current
1A
Accuracy
1% at 1A, 5% at 20A
Accuracy Limit Factor (ALF)
20
Phase Maximum Error
1 degree
Class
5P20 (IEC 61869-2)
Continuous Thermal Current
150% (1.5A)
Short-Time Thermal Current
20A
Short-Time Thermal Current Maximum Duration
4 seconds
Setting Time to Full Scale
<100μs
Operating Temperature
-25°C to 70°C / -13°F to 158°C
Overload Protection
Thermal
Operating Humidity
Non-condensing, 0 to 95% RH
Mounting
DIN TS-35/7.5 or 15 (DIN 43880) or Panel
Measurement Channels
1
Frequency Range
50/60Hz
Impedance/Burden
0.25Ω
Nominal Current
1A
Full Scale Maximum Error
1% @ 1A, 5% @ 20A
Certifications
UL Listed (E359521), CE Mark