segment table. The rate parameter is one of 0,1,2,3(0:sharp; 1:peak; 2:valley; 3:even).
6. Holiday setting: the number of holiday is integer from 0-30, after finishing the
setting, it would be holiday setting, which format is xx month-xx date.
Note:
User can customarize the factory settings of time zone segment. When no
asking, the meter would be set as the default factory settings. Users can recover the time
zone segment setting value to the default value through communication.
The use of TOU energy holidays: in the TOU energy parameter setting part, firstly we
should set the number of holidays, then set the demanded holiday in the holiday setting
bar, the format is xx month- xx date. At this time, through setting the meter operate time,
when the meter’s operation time is in the setting time, the energy would increase under
the corresponding rate.
Note:
time-division energy is with the highest priority on holidays, when the set of
special date is valid, the measurement of energy would consider the holidays at first.
Weekly restfunction
The use of TOU energy weekly rest: weekly rest(bit0- Sunday; bit1-bit6: Monday-
Saturday . when bit is 1, it means weekday, when bit is 0 , it means weekend.) through
setting the clock, when the meter’s clock is under the weekly rest time segments, the
energy would increase under the corresponding rate.
b)The value of the currentrate of self-communication order.
Daylight Saving Time function
Under the DST enable condition, if we choose fixed date option, it would change the
DST according to the fixed date setting format. The format is month/date/hour/minute/
adjust time(unit:min). if we choose unfixed date option, it would change the DST according
to the unfixed date setting format.The format is month/ week/which week/hour/minute/
Содержание AcuRev 1300
Страница 1: ...User s Manual AcuRev 1300 3P4W Energy Meter...
Страница 2: ......
Страница 8: ...VI AcuRev 1300...
Страница 9: ...1 AcuRev 1300 1 1 Meter Overview 1 2 Areas of Application 1 3 Product Features Chapter 1 Introduction...
Страница 13: ...5 AcuRev 1300 Chapter 2 Installation 2 1 Appearance and Dimensions 2 2 Installation Methods 2 3 Wiring...
Страница 28: ...20 AcuRev 1300 Relay output wiring diagram 220Vac Auxiliary Power Supply L N G V com R1 R2 Relay Output...
Страница 30: ...22 AcuRev 1300...
Страница 41: ...33 AcuRev 1300...
Страница 42: ...34 AcuRev 1300...
Страница 112: ...104 AcuRev 1300...
Страница 118: ...110 AcuRev 1300 Appendix D Revision History Version Date Description V2 01 20141021 First version V2 02 20150923...
Страница 119: ...111 AcuRev 1300...