Models:  CM411L & CM411LBI (white with lock) 

 

  CM421BL & CM421BLBI (black with lock) 

 

Capacity:  4.1 cubic feet 

 

Electrical Rating:  115V AC / 60Hz / 1.4A / 100W 

 

Refrigerant:  R134a, 1.75 oz 

 

Installation:  Free-standing (CM411L, CM421BL) 

 

  Built-in (CM411LBI, CM421BLBI) 

 

Unit Weight:  57 lbs 

 

Unit Dimensions:  19

"W x 23¼"D x 33¼"H* 

        * For built-in models (-BI suffix), height can be adjusted from 33¼" to 34½" 
        * For models with suffix ADA, height is modified to 32” for use under lower counters  
 
 

 
 

Installation Instructions 

Before Using Your Refrigerator

 

Remove the exterior and interior packing. 

 

Check to be sure you have all of the following parts: 

 

1 drip tray 

 

1 ice cube tray 

 

2 wire shelves (models CM411L & CM411LBI) 

 

2 glass shelves (models CM421BL & CM421BLBI) 

 

1 crisper drawer with glass cover 

 

1 handle with screws and handle seal 

 

2 keys  

 

Before connecting the unit to the power source, let it stand for approximately 2 
hours. This will reduce the possibility of a malfunction in the cooling system from 
handling during transportation. 

 

Clean the interior surfaces with lukewarm water using a soft cloth. 

 

Installing the Refrigerator

 

Place your unit on a floor that is strong enough to support the unit when it is fully 
loaded. To level your unit, adjust the leveling legs at the bottom. 

 

Models CM411L and CM421BL are designed to be free-standing only, and should 
not be recessed or built in.  On the other hand, models CM411LBI and 
CM421BLBI are specifically designed to be built in. 

 

Models CM411L and CM421BL: When installing, allow 5 inches of space at the 
back and sides of the unit, which will allow the proper air circulation to cool the 
compressor and condenser. 

NOTE:  THESE REFRIGERATORS ARE DESIGNED FOR MEDICAL OR PHARMACEUTICAL USE ONLY AND  
             ARE NOT INTENDED FOR USE AS HOUSEHOLD REFRIGERATORS. 

 

Содержание CM411L

Страница 1: ..._________ REFRIGERATORS with CHILLER COMPARTMENT Models CM405 CM411L CM421BL Owner s Manual BEFORE USE PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS FELIX STORCH INC 770 Garrison Avenue Bronx NY 10474 www medicalrefrigerators com CM411L CM411LBI CM421BL CM421BLBI ...

Страница 2: ...are not followed Before the refrigerator is used it must be properly positioned and installed as described in this manual so read the manual carefully To reduce the risk of fire electrical shock or injury when using the refrigerator follow basic precautions including the following Plug into a grounded 3 prong outlet Do not remove grounding prong do not use an adapter and do not use an extension co...

Страница 3: ...ate and local codes A standard electrical supply 115V AC only 60 Hz properly grounded in accordance with the National Electrical Code and local codes and ordinances is required Do not kink or pinch the power supply cord of the refrigerator The fuse or circuit breaker size should be 15 amperes It is important for the refrigerator to be leveled in order to work properly You may need to make several ...

Страница 4: ... Refrigerator 7 8 Temperature Control Ice Cube Tray Chiller Compartment Light Switch Care and Maintenance 8 9 Defrosting Your Refrigerator Cleaning Your Refrigerator 8 Power Failure Vacation Time Moving your Unit Energy Saving Tips 9 Troubleshooting 10 Limited Warranty 11 Location of Parts Temperature control knob Door Chiller compartment ice cube tray Drip tray Crisper cover Crisper Leveling legs...

Страница 5: ...ws and handle seal 2 keys Before connecting the unit to the power source let it stand for approximately 2 hours This will reduce the possibility of a malfunction in the cooling system from handling during transportation Clean the interior surfaces with lukewarm water using a soft cloth Installing the Refrigerator Place your unit on a floor that is strong enough to support the unit when it is fully...

Страница 6: ...is unit should be properly grounded for your safety The power cord of this unit is equipped with a three prong plug which mates with a standard three prong wall outlet to minimize the possibility of electrical shock Do not under any circumstances cut or remove the third ground prong from the power cord supplied For personal safety this appliance must be properly grounded This unit requires a stand...

Страница 7: ... upper hinge cover 1 remove the two screws 2 remove the upper hinge 3 and keep it for later use 4 Remove the hole cover 7 and transfer it to the same location on the opposite side 5 Insert the lower door hinge 5 into the left side fixing the hinge into place by tightening all the screws 6 6 Remove the pin cap 9 from the left side of the upper door frame and transfer it to the same location on the ...

Страница 8: ...thermostat setting for ice making is position 6 Fill the ice cube tray two thirds full of cold water or with any liquid suitable for freezing and place the tray on the floor of the chiller compartment to freeze properly Be sure to dry the bottom of the tray or it may stick to the floor of the chiller compartment The best way to get ice cubes out of the tray is to hold the tray under cold tap water...

Страница 9: ...ck under the chiller compartment 7 Defrosting usually takes a few hours After defrosting return the thermostat dial to the desired position 8 To defrost quickly a container of warm water may be placed inside the chiller compartment CAUTION Do not use boiling water because it may damage the plastic parts In addition using a sharp or metallic instrument to remove frost may damage the cooling system ...

Страница 10: ...ur unit 3 Turn the leveling legs up to the base to avoid damage 4 Tape the door shut 5 Be sure the unit stays secure in the upright position during transportation Also protect the outside of the unit with a blanket or similar covering Energy Saving Tips The unit should be located in the coolest area of the room away from heat producing appliances and out of direct sunlight Let warm items cool to r...

Страница 11: ...it The door is opened too often The door is not closed completely The temperature control is not set correctly The door gasket does not seal properly The unit does not have the correct clearances Vibrations Check to be sure the unit is level The unit seems to be making too much noise A rattling noise may come from the flow of refrigerant which is normal As each cycle ends you may hear gurgling sou...

Страница 12: ...ducts not approved by warrantor 4 Replacement parts or repair labor costs for units operated outside the United States 5 Repairs to parts or systems resulting from unauthorized modifications made to the appliance 6 Expenses for travel and transportation for product service in remote locations 7 The removal and reinstallation of your appliance if it is installed in an inaccessible location or is no...

Отзывы: