Accucold ADA302RFZ Скачать руководство пользователя страница 9

9

 

 

service technicians, however, several commonly-used parameters are listed on page 9.

 

Door Open Alarm: 

Your unit will sound an alarm when the door is open for longer than 60 seconds. To disable this: 
  
1. 

Follow the Setting Parameters instructions on page 8.  

2. 

Find parameter 

do2

3. 

The default for the unit is set at 

1

 (Enabled). 

4. 

To disable the alarm, set the parameter to 

0

 (Disabled). 

5. 

Press the 

key, or press no key for 30 seconds, to exit. The temperature set-point will be 

saved automatically. 

 

Low Temperature Alarm: 

To set a low temperature alarm: 
1. 

Follow the Setting Parameters instructions on page 8.  

2. 

Find parameter 

A5

3. 

Use the Use the    and 

 keys to adjust the temperature.  

4. 

Press the 

key, or press no key for 30 seconds, to exit. The temperature set-point will be 

saved automatically. 

 

High Temperature Alarm: 

To set a high temperature alarm: 
5. 

Follow the Setting Parameters instructions on page 8.  

6. 

Find parameter 

A6

7. 

Use the Use the    and 

 keys to adjust the temperature.  

8. 

Press the 

key, or press no key for 30 seconds, to exit. The temperature set-point will be 

saved automatically. 

 

Alarms 

Various alarms will sound under certain conditions if the unit’s buzzer is enabled. Below is a table 
listing the unit’s alarm codes and causes:  

 

Alarm Code

 

Causes

 

E1

 

Cabinet temperature sensor fails.

 

E2

 

Evaporator sensor fails.

 

E3

 

Condenser sensor fails.

 

cH

 

High condenser temperature alarm

 

rH

 

High cabinet temperature alarm

 

rL

 

Low cabinet temperature alarm

 

 

Controls for Dial Thermostats 

 

Some units in this collection include a dial thermostat located inside the unit on the upper-right 
side wall.  

 

Turn the knob clockwise from the 

0 (OFF)

 position toward the higher numbers for colder 

temperatures. Higher settings on the dial (higher numbers) mean lower temperatures (colder) in 
the unit.  

 

Changes in the ambient temperature affect temperature in the unit, so choose an appropriate 
setting of the thermostat dial, depending on ambient conditions.  

Содержание ADA302RFZ

Страница 1: ...reezers ADA403AF User Manual BEFORE USE PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS Felix Storch Inc An ISO 9001 2015 registered company 770 Garrison Avenue Bronx NY 10474 www a...

Страница 2: ...n 5 6 Extension Cord 6 Reversing the Door Swing 6 Installing the Handle 7 Operating your Appliance 7 10 Control Panel Refrigerator and Freezer Models 7 8 Alarms 9 Defrosting 10 Shelves 10 Care and Mai...

Страница 3: ...d 3 prong outlet do not remove grounding prong do not use an adapter and do not use an extension cord Replace all panels before operating It is recommended that a separate circuit serving only your ap...

Страница 4: ...90 F 32 C The appliance should not be located next to ovens grills or other sources of high heat The appliance must be installed with all electrical water and drain connections in accordance with sta...

Страница 5: ...f the appliance is never covered or blocked in any way NOTE It is recommended that you do not install the appliance near an oven radiator or other heating source Direct sunlight may affect the acrylic...

Страница 6: ...ommended that you do not use an extension cord with this appliance However if you must use an extension cord it is absolutely necessary that it be a UL CUL Listed 3 wire grounding type appliance exten...

Страница 7: ...atures the performance of the unit may be affected For example placing your unit in extremely cold or hot conditions may cause interior temperatures to fluctuate The operating temperature range may no...

Страница 8: ...This is normal and is due to the length of the activation time There should not be a problem once the unit has been running for a few hours Setting Parameters Several temperature parameter settings ca...

Страница 9: ...rameters instructions on page 8 6 Find parameter A6 7 Use the Use the and keys to adjust the temperature 8 Press the key or press no key for 30 seconds to exit The temperature set point will be saved...

Страница 10: ...the plastic parts In addition never use a sharp or metallic instrument to remove frost as it may damage the cooling coils and will void your warranty We recommend using a plastic scraper To defrost 1...

Страница 11: ...months remove all items and turn off the appliance Clean and dry the interior thoroughly To prevent odor and mold growth leave the door open slightly blocking it open if necessary Moving your Applianc...

Страница 12: ...is open too often The door is not closed completely The door gasket does not seal properly Put the appliance in a cooler place Leave the appliance to work for a while until the set temperature has be...

Страница 13: ...set point Maximum possible set point Temperature set point 85 22 Temperature set point 185 C7 Maximum standby time after compressor start delay 0 90 0 Disabled 9 min C8 Minimum compressor on time 0 9...

Страница 14: ...Fan start delay after the controller is energized 0 60 3 min F3 Fan delay time after defrost 0 60 0 Disabled 2 min A1 Duty cycle mode in the event of a faulty cabinet sensor 0 Disable 1 Enable 1 A2 Co...

Страница 15: ...en the door is open Light is turned off when the door is closed 4 When the door is open it inputs as synchronous defrost signal i e defrost starts 0 do2 Whether buzzer responds when the door is open 0...

Страница 16: ...nt parts or repair labor costs for units operated outside the United States 5 Repairs to parts or systems resulting from unauthorized modifications made to the appliance 6 The removal and reinstallati...