NOTE:

 If the unit is unplugged, or power is lost or turned off, you must wait 3 to 5 minutes before 

restarting the unit. If you attempt to restart before this time delay, the unit will not start. 

 

Defrosting 

Refrigerators in this series defrost automatically in normal operating conditions. The evaporator 
behind the rear wall of the unit defrosts automatically. The condensate collects in the drainage 
channel behind the rear wall of the unit, and flows through the drainage hole into the drip tray by the 
compressor where it evaporates. 
 
However, frost may accumulate on the evaporator if the unit is repeatedly opened in a high heat or 
high humidity location. If this frost pattern does not clear within 24 hours, your unit will require 
manual defrosting. 

 

 

Freezer models and the freezer compartment of refrigerator-freezers require manual defrosting. For 
the most efficient operation and minimum energy consumption, defrost the freezer when the frost on 
the freezer walls is excessive or ¼ to ½” thick.  

 

CAUTION: Never use boiling water to defrost because it may damage the plastic parts. In addition, 

never use a sharp or metallic instrument to remove frost, as it may damage the cooling 
coils and will void your warranty. We recommend using a plastic scraper. 

 

To defrost: 

1. 

Remove the frozen food from the freezer and place it in another cooling device 

2. 

Turn the thermostat off and unplug your freezer, leaving he door open to help speed up the 
defrosting process 

3. 

Use a sponge or toweling to remove water and melting ice from the freezer floor. Pouring warm 
(not boiling) water on the ice/frost may also help speed the defrosting process.  

4. 

Clean and thoroughly dry the freezer interior 

5. 

Close the door and plug the freezer in, resetting the thermostat to the desired setting 

6. 

Allow several hours for the cabinet to reach the proper storage temperature 

 

Shelves 

To prevent damaging the door gasket, make sure to have the door all the way open when pulling the 
shelves out of the rail compartment. 

•  Any of the shelves can be removed to store larger items. 
•  When removing the shelf from the rail compartment, 

make sure to remove all items first.  Then move the shelf 
to the position where the notch of the shelf is exactly 
under the plastic post and lift the shelf. In order to replace 
the shelf, repeat steps described above in reverse. 

 

 

Содержание ADA302RFZ

Страница 1: ...reezers ADA403AF User Manual BEFORE USE PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS Felix Storch Inc An ISO 9001 2015 registered company 770 Garrison Avenue Bronx NY 10474 www a...

Страница 2: ...n 5 6 Extension Cord 6 Reversing the Door Swing 6 Installing the Handle 7 Operating your Appliance 7 10 Control Panel Refrigerator and Freezer Models 7 8 Alarms 9 Defrosting 10 Shelves 10 Care and Mai...

Страница 3: ...d 3 prong outlet do not remove grounding prong do not use an adapter and do not use an extension cord Replace all panels before operating It is recommended that a separate circuit serving only your ap...

Страница 4: ...90 F 32 C The appliance should not be located next to ovens grills or other sources of high heat The appliance must be installed with all electrical water and drain connections in accordance with sta...

Страница 5: ...f the appliance is never covered or blocked in any way NOTE It is recommended that you do not install the appliance near an oven radiator or other heating source Direct sunlight may affect the acrylic...

Страница 6: ...ommended that you do not use an extension cord with this appliance However if you must use an extension cord it is absolutely necessary that it be a UL CUL Listed 3 wire grounding type appliance exten...

Страница 7: ...atures the performance of the unit may be affected For example placing your unit in extremely cold or hot conditions may cause interior temperatures to fluctuate The operating temperature range may no...

Страница 8: ...This is normal and is due to the length of the activation time There should not be a problem once the unit has been running for a few hours Setting Parameters Several temperature parameter settings ca...

Страница 9: ...rameters instructions on page 8 6 Find parameter A6 7 Use the Use the and keys to adjust the temperature 8 Press the key or press no key for 30 seconds to exit The temperature set point will be saved...

Страница 10: ...the plastic parts In addition never use a sharp or metallic instrument to remove frost as it may damage the cooling coils and will void your warranty We recommend using a plastic scraper To defrost 1...

Страница 11: ...months remove all items and turn off the appliance Clean and dry the interior thoroughly To prevent odor and mold growth leave the door open slightly blocking it open if necessary Moving your Applianc...

Страница 12: ...is open too often The door is not closed completely The door gasket does not seal properly Put the appliance in a cooler place Leave the appliance to work for a while until the set temperature has be...

Страница 13: ...set point Maximum possible set point Temperature set point 85 22 Temperature set point 185 C7 Maximum standby time after compressor start delay 0 90 0 Disabled 9 min C8 Minimum compressor on time 0 9...

Страница 14: ...Fan start delay after the controller is energized 0 60 3 min F3 Fan delay time after defrost 0 60 0 Disabled 2 min A1 Duty cycle mode in the event of a faulty cabinet sensor 0 Disable 1 Enable 1 A2 Co...

Страница 15: ...en the door is open Light is turned off when the door is closed 4 When the door is open it inputs as synchronous defrost signal i e defrost starts 0 do2 Whether buzzer responds when the door is open 0...

Страница 16: ...nt parts or repair labor costs for units operated outside the United States 5 Repairs to parts or systems resulting from unauthorized modifications made to the appliance 6 The removal and reinstallati...

Отзывы: