background image

 

 

1. Safety Instructions (continued) 

 

 

Follow all warnings and instructions marked on the unit. 

 

This product is meant to be operated in an indoor environment with 

proper ventilation. 

 

Do not place near direct sunlight, heat sources, or air conditioners. 

 

This product should only be operated with the power cord supplied and 

the type of power source indicated in this user guide. If you are not sure 

of the type of power supply in your location, consult your vendor or local 

power company. 

 

To avoid the risk of fire or electric shock, never push objects into the unit 

through the case slots or openings, since they may touch dangerous 

voltage points or shortcut parts. Do not disassemble the unit. 

 

Never spill liquids of any kind on the product. 

 

Unplug this product from the wall outlet and refer servicing to qualified 

service personnel under the following conditions: 

When the power supply cord or plug is damaged or frayed* 

If liquid has been spilled into the unit, or it has been exposed to rain 

or water* 

If the product has been dropped or the case has been damaged* 

If the product shows a noticeable change in performance 

 

*Not covered under warranty 

 

NOTE:

 Do not remove the "ground" prong from the power cord. It is a safety 

feature meant to protect the user from harm and the equipment from damage. 

 

If the unit does not operate normally while following the 

instructions, adjust only those controls covered by the operating 

instructions. Improper adjustment of other controls may result in 

damage and will often require extensive work by a qualified 

technician to restore the product to normal operation. 

 

Содержание AB5800

Страница 1: ...1 AB5800 Bank Grade Value Extension Bill Counter USER GUIDE www AccuBANKER com...

Страница 2: ...Thank you for trusting AccuBANKER with your cash handling needs In order to optimize the performance of your equipment we encourage you to thoroughly read this user guide prior to use...

Страница 3: ...8 3 Equipment Overview 9 3 1 Part Description 9 3 2 Control Panel Description 10 3 3 Functions Detection Sensitivity Adjustment MG UV DD LEVEL 15 3 4 Display Brightness adjustment 15 4 Operation 16 4...

Страница 4: ...nt features this model offers are 1 Manual Value Extension function allows the user to obtain the total value of a batch for a selected denomination and the grand total value of all the batches counte...

Страница 5: ...y result in electric shock fire or cause serious damage to the unit Do not operate the unit in areas with high temperature or high humidity sinceit may prevent it from working correctly Caution When u...

Страница 6: ...ll liquids of any kind on the product Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions When the power supply cord or plug is d...

Страница 7: ...ed Plug the power cable to the back of the bill counter and into the wall power outlet Turn the equipment on 2 2 Bill Guider Installation Proceed to install them as follows 1 Align the guider with the...

Страница 8: ...folded or damaged bills B Check for foreign objects mixed up with the bills such as paper clips rubber bands pieces of paper etc C If counting new bills fan them lightly since they often stick togeth...

Страница 9: ...Stacker Sensor Senses counted bills 7 Stacker Tray Counted bills are collected here 8 Carry Handle Used to carry transport the equipment 9 Feeding Gap Adjustment Knob Adjusts the width of the opening...

Страница 10: ...ling the quantity of bills for every denomination counted Use the UP or DOWN arrows keys to scroll through the list The TOTAL line will display the total count result Press START to go back to the mai...

Страница 11: ...pecific denomination value b Press CURR repeatedly short press until the screen shows LOCAL c Keep the CURR key pressed for 3 seconds until the screen shows all the denominations available d Use the U...

Страница 12: ...nfirm the selection and go back to the counting screen When the highest speed 1800 bill min is chosen the MG function is not available to be selected by the user For Polymer bills MXN CAD currencies t...

Страница 13: ...that have a different width size for every denomination like EURO It is highly recommended to activate DD when counting POLYMER bills like CAD or MXN LEVEL Allows the adjustment of the emission inten...

Страница 14: ...Off This function allows the unit to add up all the consecutive operations made with the ADD activated NOTE ADD function plays an important role if you want to count several denominations that belong...

Страница 15: ...set up then press START to validate the selection and return to the counting mode NOTE In case the unit frequently reports error messages related to any security feature MG UV DD consider verifying th...

Страница 16: ...in the hopper and the unit will start counting them automatically NOTE If the unit is set to MANUAL press START to begin the counting operation 4 2 Miscounting errors In case the unit is not having an...

Страница 17: ...nd error attempts are recommended before you make the final adjustment a for new thinner notes adjust toward to reduce the gap b for used thicker notes adjust toward to increase the gap c small adjust...

Страница 18: ...s Adjust thickness adjustment knob Consider reducing LEVEL sensitivity DD Alarm Check the size of the bill width Verify the specific bill Consider reducing DD sensitivity Half Error Check for a mutila...

Страница 19: ...condition Stacker Capacity 200 bills good fitness condition Banknote size range 4 x 1 97 7 x 3 1 in Display High Resolution LCD Display Power Source 100 240 VAC 60 50 Hz Power Consumption 30 Watts in...

Страница 20: ...20 AccuBANKER USA 7104 NW 50th St Miami FL 33166 9AM 5PM ET Monday through Friday www AccuBANKER com Please give us a call at 1 888 993 2228...