4.4 Cleaning the Optical Sensors

For ensuring an accurate unit’s functioning is recommended to clean its optical 
sensors periodically. Dust or any kind of dirt will affect the unit’s performance 
considerably.

The glass surfaces of the sensors may be wiped with a soft cloth soaked with 
alcohol every week at least.
1. Hopper sensors
2. Counting sensors
3. Stacker sensors

Содержание AB5500

Страница 1: ...User Guide VALUE EXTENSION BILL COUNTER AB5500...

Страница 2: ...cription 10 3 Basic Operation 12 3 1 Power Up 12 3 2 Counting Mode 12 3 3 Functions Selection 12 3 4 Manual Value Extension function 12 3 5 Report Print function 12 4 Troubleshooting Operational Probl...

Страница 3: ...instructions may result in electric shock fire or damage to the unit Do not use the unit if the power cord is damaged or if the plug socket contact is loose Not following these instructions may result...

Страница 4: ...tage points or shortcut parts resulting in a risk of fire or electric shock Never spill liquids of any kind on the product Unplug this product from the wall outlet and refer to servicing by qualified...

Страница 5: ...ve time and money during your management account ing operations This User Guide covers the Installation Operation and Troubleshooting pro cedures of the AB5500 We recommend reading this guide thorough...

Страница 6: ...z European Standard Plug the power cable to the back of the unit and into the wall outlet Turn the unit on and verify its functioning In case of any functioning problem get contact immediately with yo...

Страница 7: ...nstruction given in the Section Error Messages 1 3 Thickness Knob Adjustment Procedure 1 The Thickness Adjustment Knob is set at 0 as the standard setting from factory 2 Having the right thickness adj...

Страница 8: ...trols 2 1 Parts Description 1 Hopper Guiders 2 Hopper 3 Emergency stop button 4 Control Panel 5 Stacker 6 Bill Thickness Adjustment knob 7 Handle 8 External Display jack 9 RS 232 printing port 10 Powe...

Страница 9: ...not allow you to set up EURO denominations MNL Automatic or Manual starting mode The unit begins counting automatically when banknotes are placed in the hopper To control manually this action manually...

Страница 10: ...bill is considered suspicious The UV sensitivity also could be customized by pressing the UV key for 3 sec and using the buttons to reach the desired sensitivity setting Press RESTART to validate the...

Страница 11: ...Selection Select the function you want to use by pressing the specific button on the key board a UV and MG functions are used to verify the authenticity of each note Press ing them sequentially the d...

Страница 12: ...the jammed bill from the unit 4 Now carefully proceed to remove the jammed note from the unit s interior 5 Look for any additional foreign object such as a piece of bill paper clips rub ber band etc a...

Страница 13: ...ecommended to clean its optical sensors periodically Dust or any kind of dirt will affect the unit s performance considerably The glass surfaces of the sensors may be wiped with a soft cloth soaked wi...

Страница 14: ...Press RESTART for confirming the new selection Note USD and EURO currencies have their own UV setting 4 6 MG Sensitivity Adjustment The user is enable to adjust a specific setting for this function co...

Страница 15: ...the fitness quality of the bills b Bills jammed inside the unit b Consider re adjust the thickness adjustment HALF ALARM Bill size problem Remove the problematic bill PLACE NOTES ON THE HOPPER The hop...

Страница 16: ...lls or 300 new bills Stacker Capacity 100 old bills or 200 new bills Banknote size range 115mm x 50mm 170mm x 85mm Display High Resolution LCD Display Power Source 100 240 VAC 60 50 Hz Power Consumpti...

Отзывы: