background image

 

 

 

OPERATIONS MANUAL 

 

ACCU1 9118 
ACCU1 9218 
ACCU1 9400 
ACCU1 9500 

 

 

 

 

 

 

Accu1Direct, Inc

 

www.Accu1.com

 

Telephone: 800-438-2776 

Email: [email protected] 

115/230 

 

Содержание ACCU1 9118

Страница 1: ...1 OPERATIONS MANUAL ACCU1 9118 ACCU1 9218 ACCU1 9400 ACCU1 9500 Accu1Direct Inc www Accu1 com Telephone 800 438 2776 Email sales accu1 com 115 230...

Страница 2: ...are present Keep ALL BODY PARTS away from rotating elements Disconnect power cords before working on machine NEVER RELY ON THE SWITCHES TO TURN THE MACHINE OFF DISCONNECT AND REMOVE ALL POWER CORDS TO...

Страница 3: ...cess CONDITIONING CARD to interior Location for insertion of secondary material conditioning devices 10 SERIAL NUMBER Plate on which serial number is engraved 4 AIRLOCK CHAMBER All steel chamber with...

Страница 4: ...ther conditions Open Blow Attic with 100ft 30 48m of 2 6 35 cm blowing hose Product gate Remove completely Sidewalls With 50ft 15 24m of 2 6 35 cm blowing hose and 50 6 35 cm of 2 5 08cm hose Using 1...

Страница 5: ...2 6 35 cm blowing hose Product Gate Remove completely Air Speed 10 if too dusty reduce air setting Sidewalls With 50 ft 15 24m of 2 6 35 cm blowing hose Using 1 2 54cm reducing nozzle Product Gate Op...

Страница 6: ...6 Accu1 9400...

Страница 7: ...7 Accu1 9500...

Страница 8: ...peed 1 2 way between low and medium Hose 3 x 50 blowing hose all the way to the attic Wall Spray all fibers Use 2 rectangular hole card and set material gate 1 2 open Air Speed 6 8 Hose 3 x 50 to 3 x5...

Страница 9: ...foul The points may require cleaning replacement or on some models reattachment of the wires to the auxiliary set of points Transformers The low voltage to operate the switches and contactors comes f...

Страница 10: ...aster setting the material receives more conditioning but the rate of production may decrease a smaller amount of material will be delivered to the end of the hose As you decrease the drive speed the...

Страница 11: ...carelessness When a knife is dropped into the hopper it must be removed at one to prevent jamming or damaging the machine REMEMBER ALWAYS TURN THE MACHINE OFF AND UNPLUG AND REMOVE THE CORDS BEFORE AT...

Страница 12: ...Tension Chains Tension Electrical Connections for Material Build Up Clean as Needed Contactors for Erosion or Pitted Points Motor Vents Cleaned Out NOTE DO NOT LUBRICATE CHAIN Chain is permanently lu...

Страница 13: ...en set screws on both airlock bearings 4 Remove bearings on front and back airlock plate 5 Remove front airlock plate outlet tube plate 6 Remove rotor 7 Remove old seals 8 Clean rotor and check for da...

Страница 14: ...he test section is scrapped from the substrate being sprayed and oven dried before being weighed FIRE RESISTANCE RATING The ability of a building construction assembly to resist the migration of a fir...

Страница 15: ...set 4 Remove old seals and replace with new Remote will not operate 1 Main power switch off 2 Remote cord not plugged in 3 Faulty cord 4 Transformer burned out 1 Check all settings turn on 2 Check con...

Страница 16: ...it was designed Manufacturer guarantees the blower motor and the electrical components for a period of ninety days from the date of factory shipment If the product fails under normal operating condit...

Страница 17: ...Please circle your PRIMARY line of business Please circle all that apply How did you learn of our products Please circle ONE What features most interested you Please circle all that apply Automobile C...

Страница 18: ...18...

Отзывы: