background image

 
 
 
 

Page 8 

 

-

 

Press the red 

Stop

 button. The Model 9700 will not come on again until 

the green 

On

 button is pressed again.  

 

 

Machine Adjustments 

 
Blowers:  

  

-

 

Use 

Blower Speed

 dial located on electrical panel. Lower numbers  

     represent lower speed; higher numbers represent higher speed.  

  

Material:  

  

-

 

To increase material flow, turn the 

material feed screw

 located at     

     the rear of the machine clockwise with the hand crank provided. T0   
     decrease flow, turn the screw counter clockwise.  
  

Agitator / Rotor Speed:  

  

-

 

Access the 

motor positioning screw

 through the slot on the side of    

     the machine beneath the Control Panel using the ratcheting    
     wrench provided. Speed is increased as belt tension is lowered.   
     Speed decreases as belt tension is raised. Both agitator and airlock  
     rotor speed are adjusted proportionally in this manner.  

 

 

 

Содержание 9700

Страница 1: ...Owner s Manual Model 9700 All Fiber Blower Accu1Direct Inc 138 Denslow Road East Longmeadow MA 01028 Tel 800 438 2776 Fax 413 224 1294 www accu1 com...

Страница 2: ...ts 1 Warranty Page 3 2 Principles of Operation Page 4 3 Maintenance Page 5 4 Warnings Page 6 5 Operating Instructions Page 7 6 Machine Adjustments Page 8 7 Airlock Seal Change Instructions Page 9 8 Tr...

Страница 3: ...y evaluation it is determined that the machine has been used in any way other than the purpose for which it was designed Accu1Direct reserves the right to void the warranty 5 All warranty claims must...

Страница 4: ...that it can be 2 Moved by pressurized air through hoses to the desired spaces Fiber materials are loaded into the machine hopper The agitator arms break up the materials while the auger moves the mate...

Страница 5: ...F THE HOPPER will be rewarded with many years of top performance NOTE DO NOT LUBRICATE CHAIN Chain is permanently lubricated at the factory Lubricating chain will cause it to wear faster because chain...

Страница 6: ...achine 4 Keep hands and arms out of the hopper and away from moving parts 5 Do not leave the machine unattended while running 6 Keep hands and face away from hose end while machine is operating 7 Only...

Страница 7: ...tion If volt meter reads less than normal voltage move the Boost switch to the ON position Press the green On button The Remote and Blower Only switches are now operational For Blower Only operation s...

Страница 8: ...al flow turn the material feed screw located at the rear of the machine clockwise with the hand crank provided T0 decrease flow turn the screw counter clockwise Agitator Rotor Speed Access the motor p...

Страница 9: ...et screws on both airlock bearings 4 Remove bearings on front and back airlock plates 5 Remove front airlock plate outlet tube plate 6 Remove rotor 7 Remove old seals 8 Clean rotor and check for damag...