background image

3000-LED MICROSCOPE SERIES 

ACCU-SCOPE

®

20

 

MAINTENANCE 

Please remember to 

never 

leave the microscope with any of the objectives or eyepieces removed and 

always protect the microscope with the dust cover when not in use. 

SERVICE 

ACCU-SCOPE

 ®

 microscopes are precision instruments which require periodic servicing to keep them 

performing properly and to compensate for normal wear. A regular schedule of preventative maintenance 
by qualified personnel is highly recommended. Your authorized ACCU-SCOPE

 ®

 distributor can arrange 

for this service. Should unexpected problems be experienced with your instrument, proceed as follows: 

1. Contact the ACCU-SCOPE

 ®

 distributor from whom you purchased the microscope. Some

problems can be resolved simply over the telephone.

2. If it is determined that the microscope should be returned to your ACCU-SCOPE

 ®

 distributor or to

ACCU-SCOPE

 ®

 for warranty repair, pack the instrument in its original Styrofoam shipping carton. If you

no longer have this carton, pack the microscope in a crush-resistant carton with a minimum of three
inches of a shock absorbing material surrounding it to prevent in-transit damage. The microscope should
be wrapped in a plastic bag to prevent Styrofoam dust from damaging the microscope. Always ship the
microscope in an upright position; 

NEVER SHIP A MICROSCOPE ON ITS SIDE

. The microscope or

component should be shipped prepaid and insured.

LIMITED MICROSCOPE WARRANTY

 

This microscope and its electronic components are warranted to be free from defects in material and workmanship 
for a period of five years from the date of invoice to the original (end user) purchaser.  The LED lamp is warranted 
for a period of two years from the date of invoice to the original (end user) purchaser.  This warranty does not cover 
damage caused in-transit, misuse, neglect, abuse or damage resulting from improper servicing or modification by 
other then ACCU-SCOPE approved service personnel.  This warranty does not cover any routine maintenance 
work or any other work, which is reasonably expected to be performed by the purchaser. Normal wear is excluded 
from this warranty. No responsibility is assumed for unsatisfactory operating performance due to environmental 
conditions such as humidity, dust, corrosive chemicals, deposition of oil or other foreign matter, spillage or other 
conditions beyond the control of ACCU-SCOPE INC.  This warranty expressly excludes any liability by ACCU-
SCOPE INC. for consequential loss or damage on any grounds, such as (but not limited to) the non-availability to 
the End User of the product(s) under warranty or the need to repair work processes.  Should any defect in material, 
workmanship or electronic component occur under this warranty contact your ACCU-SCOPE distributor or ACCU-
SCOPE at (631) 864-1000.  This warranty is limited to the continental United States of America.  All items returned 
for warranty repair must be sent freight prepaid and insured to ACCU-SCOPE INC., 73 Mall Drive, Commack, NY 
11725 – USA.  All warranty repairs will be returned freight prepaid to any destination within the continental United 
States of America, for all foreign warranty repairs return freight charges are the responsibility of the 
individual/company who returned the merchandise for repair.  

ACCU-SCOPE is a registered trademark of ACCU-SCOPE INC., Commack, NY 11725 

Содержание 3000-LED-SPH

Страница 1: ...MANUAL 3000 LED MICROSCOPE SERIES 100 Lauman Lane Suite A Hicksville NY 11801 Tel 877 877 7274 Fax 516 801 2046 Email Info nyscopes com www microscopeinternational com LVWULEXWHG E...

Страница 2: ...4 5 ASSEMBLY DIAGRAM PROCEDURE 6 8 ADJUSMENT OPERATION ILLUMINATION 9 MIRROR 9 SPECIMEN SLIDE 9 FOCUSING 10 INTERPUPILLARY DISTANCE 10 FIELD DIAPHRAGM 11 APERTURE DIAPHRAGM 11 OIL OBJECTIVE 12 FILTER...

Страница 3: ...ctives or focusing assembly 2 Keep the instrument clean remove dirt and debris regularly Accumulated dirt on metal surfaces should be cleaned with a damp cloth More persistent dirt should be removed u...

Страница 4: ...t quality prior to shipment UNPACKING AND COMPONENTS Your microscope arrived packed in a molded Styrofoam container Do not discard the container the Styrofoam container should be retained for reshipme...

Страница 5: ...CROSCOPE SERIES ACCU SCOPE 5 COMPONENTS DIAGRAM Lock Screw Y Axis Adjustment Knob Coarse Focusing Knob Fine Focusing Knob X axis Adjustment Knob Power Switch Iris Diaphragm Adjustment Control Objectiv...

Страница 6: ...preassembled by our factory technicians at our New York facility prior to shipment Should you need to disassemble assemble your microscope in the future please follow the instructions outlined below...

Страница 7: ...oosen the condenser lock screw Insert the condenser into the hole of the stand according to the directional arrow until the condenser is even with the stand and then rotate the condenser to make sure...

Страница 8: ...r of power cord securely into the power socket see Fig 3 Insert the other connector securely into an electrical outlet The microscope uses a universal power supply so it may be used in any voltage ran...

Страница 9: ...power switch to the 0 off position Loosen the Allen screw with an Allen wrench to screw off the built in illuminator housing see Fig 5 Screw on the mirror according to the directional arrow and tight...

Страница 10: ...your left eye only and the 10X objective focus your specimen by adjusting the coarse adjustment knob When the image is in view refine the image to its sharpest focus by turning the fine adjustment kn...

Страница 11: ...r Illuminator Condenser Optional Adjusting the Aperture Diaphragm The aperture size is increased or decreased by rotating the condenser aperture diaphragm lever When the aperture is closed the brightn...

Страница 12: ...xR oil immersion objective is in the light path With your eye at the level of the stage use the coarse focus knob to raise the stage with the specimen cover glass When you see a flash of light at this...

Страница 13: ...ugh side downward onto the groove of the illuminator condenser Place the cover back on the illuminator condenser and re install the set screw Fig 13 Filters are available in clear blue frosted blue gr...

Страница 14: ...rn the main switch to 0 OFF before replacing the LED bulb Unplug the power cord from the microscope Gently place the microscope on its arm as shown in Figure 15 Using a Philips head screwdriver remove...

Страница 15: ...ulb in position and screw it to its mount Figure 19 Figure 18 above Reinstall the base plate and reconnect the make break connector with the connector from the new bulb Figure 20 Secure the base plate...

Страница 16: ...range 76x50mm Condenser Built in Koehler illuminator systems Pre centered Iris diaphragm Koehler illuminator condenser and mirror optional Illuminator Universal power supply 90 240V voltage 3W LED lig...

Страница 17: ...e objective correctly into the optical path Dirt or dust on the view field Dirt or dust on the lens eyepiece condenser objective collector lens or specimen Clean the lens Poor image quality No cover g...

Страница 18: ...dial and or iris diaphragm Insufficient brightness Lamp intensity is too low Aperture diaphragm closed too far Condenser position too low Adjust the light intensity by rotating the intensity control...

Страница 19: ...No electrical power Lamp bulb burnt out Fuse blown out Check power cord connection Replace bulb Replace fuse Slippage of focus when using the coarse focusing knob Tension adjustment is set too low Inc...

Страница 20: ...years from the date of invoice to the original end user purchaser The LED lamp is warranted for a period of two years from the date of invoice to the original end user purchaser This warranty does no...

Отзывы: