background image

1

2

1

7

8

9

11

13

6

5

4

16

17

18

19

21

20

22

15

2

3

10

14

12

1

2

Main menu

Test

Turn off

Memory

Settings

Result

Set flag

All results

Time/Date

Tones

Reminders

Target range

Volume

Control test

Color

Averages

Time

Beeper

New

Turn on    Turn off

General

On  Off

All results

7 days

Date

Reminders

Edit

Change

Brightness

Before meal

On  Off

Before meal

14 days

Time format

Acoust. mode

In 1 hour

Turn on  Turn off

Cancel

After meal

On  Off

After meal

30 days

In 2 hours

Change

Language

Reminder

Reminders

Transfer data

In 3 hours

Delete

For analysis

Cancel

Table to PC

Display format

Single value

List

Main menu

Tools

Display check

Validity

Clean

Change cass.

Preparing the lancing device for obtaining 
new blood sample: 

load new lancet

When all 6 lancets have been used: 

remove lancet drum

Changing an empty cassette

Push lever to right and back again

1

  Remove cap 

2

   Pull out drum 

1

  Open tip cover 

2

  Release cassette 

compartment cover

3

   Open cassette 

compartment cover

4

  Remove empty 

cassette

5

   Insert new cassette 

9

  Press 

 button 

6

   Close cassette 

compartment cover

10

  Press 

 button 

7

   Press cover to close 

11

   Main menu is 

displayed

8

   Press 

 button 

12

   Close tip cover 

CLICK

Functions of the buttons

Adjust settings

Overview of the meter 

Overview of the lancing device 

Menu overview 

Turning meter on or off

Press 

 button

Moving down a menu

Press 

 button

1

  Turn on meter

4

  Select 

Settings

Executing a command

Press 

 button

Counting upwards

Press 

 button

2

  Wait for displays

5

  Open

 Settings

Counting downwards

Press 

 button

Moving up a menu

Press 

 button

3

 

Main menu 

is displayed

Settings

 menu overview

press and hold longer than  

2 seconds

 press and hold  

longer than 2 seconds

1

  Battery compartment cover (right: from above; far 

right: open)

2

  Infrared window

3

  Batteries [1.5 V, type AAA, alkaline-manganese or 

high energy batteries (2 batteries required)]

4

  Lancing device (docked)

5

  Tip cover (bottom: open)

6

  Test area (at the tip of the cassette ready for a test) 

– this is where you apply the blood

7

  Down/Up buttons

8

  On/Off and Enter button

9

  Display

10

  Release button for undocking the lancing device

11

  Type plate

12

  Release button for opening the cassette compart-

ment cover

13

  Cassette compartment cover (right: open)

14

  Test cassette (in place in the meter)

15

  Multifunction button (priming and lancing)

16

  Lever for rotating the lancet drum and loading a new 

lancet

17

  Lancet drum containing 6 lancets

18

  Numbers indicating penetration depth settings

19

  Rotatable cap (rotating the cap on the device sets 

the penetration depth)

20

  Pin-hole opening for lancet

21

  Penetration depth indicator

22

  Window showing number of available lancets

Select with 

Open or set with 

This Quick Reference Guide is not a substitute for the full User’s Manual supplied with your 