Advanced Reference Guide

Fast SwitcHub-8mi SNMP

1

Contents

Introduction

1

Making the Connections Required for System Configuration

1

Onsite Connection

1

Modem Connection

1

Telnet Connection

2

In-Band Network Connection

2

Configuring Your System with the On-Board Program

2

Using the System Configuration Program

3

Performing Basic Configuration

4

Changing the System Configuration

4

Assigning SNMP Parameters

6

Changing System Passwords

8

Port Grouping Configuration

8

Configuring Port Parameters

9

Using the Spanning Tree Algorithm

10

Configuring the Out-of Band Console

13

Displaying Statistics and Configuration Data

14

Displaying a Description of the Switch

14

Displaying Switch and Port Statistics

14

Displaying the Address Table

16

Displaying Port Status

16

Viewing the Current Spanning Tree Configuration

17

Downloading System Software

18

Using TFTP Protocol to Download over the Network

18

Using the Serial Port to Download Out-of-Band

19

Resetting the System

19

Logging Off the System

20

Troubleshooting

20

Telnet Access

20

Pin Assignments for Serial Port Connections

20

DB9 Serial Port Pin Description

20

DB9 Port Pin Assignments

21

Connecton from Switch’s 9-Pin Serial Port to PC’s 9-Pin COM Port

21

Connecton from Switch’s 9-Pin Serial Port to Modem’s25-Pin DCE Port

21

Connecton from Switch’s 9-Pin Serial Port to PC’s 25-Pin DTE Port

21

Introduction

The on-board management agent in the Fast SwitcHub-8mi SNMP provides the switch

with advanced management capabilities.  The SwitcHub’s SNMP agent module includes

a menu-driven configuration program that can be accessed by connecting a terminal or

PC to the serial port on the rear panel.  You can also access the configuration program

by an in-band Telnet connection, or perform in-band management from any network

management station running SNMP management software (e.g., AccView/Open).
The on-board configuration program allows you to perform the following tasks:

•

Enable/disable any port

•

Set the communication mode for any port

•

Set the switching mode

•

Configure SNMP parameters

•

Configure VLAN port grouping

•

Enable and configure the Spanning Tree Algorithm

•

Restart the system

Making the Connections Required for System Configuration

The SwitcHub provides a menu-driven configuration program.  Also the SNMP agent

allows you to manage the switch from any PC attached to the network using in-band

network management software (e.g., AccView/Open).

Note:

Limited configuration (i.e., selecting the port transmission mode) and panel

display selection can be carried out with the Configure button on the front panel.

(Refer to the Quick Installation Guide.)

This section describes how to access the menu-driven configuration program via:

•

Onsite connection

- A terminal or workstation directly connected to the serial port

on the switch.

•

Modem connection

- A workstation connected to a remote SwitcHub via modems.

•

Telnet connection

- A workstation connected to a remote SwitcHub via a network

Telnet connection.

It also describes how to access the on-board SNMP agent over the network from a

network management station (NMS) using network management software.

Onsite Connection

Attach a VT100 compatible terminal or a PC running a terminal emulation program to the

serial port on the SwitcHub’s rear panel.  Use the null-modem cable provided with the

product package, or use a null modem cable that complies with the wiring assignments

shown in the back of this guide.
When attaching to a PC, set terminal emulation type to VT100, specify the port used by

your PC (i.e., COM 1~4), and then set communications to 8 data bits, 1 stop bit, no

parity, and 9600 bps.  Also be sure to set flow control to "none."

Modem Connection

Configure the SwitcHub Site: Connect the switch's DB9 port to the modem's serial port

using standard cabling.  For most modems which use a 25-pin port, you will have to

provide an RS232 cable with a 9-pin connector on one end and a 25-pin connection on

the other end.  You do not have to set the modem at the switch's site, because the

switch will automatically configure it to auto-answer mode.

Содержание Fast SwitcHub-8mi SNMP

Страница 1: ...Fast SwitcHub 8mi SNMP Advanced Reference Guide ES3508 TX E0398 R01 150849 101...

Страница 2: ...he information in this document is subject to change without notice Accton reserves the right to make revisions to this publication without obligation to notify any person or entity of any such change...

Страница 3: ...ollowing tasks Enable disable any port Set the communication mode for any port Set the switching mode Configure SNMP parameters Configure VLAN port grouping Enable and configure the Spanning TreeAlgor...

Страница 4: ...Hub 8mi SNMP c Copyright Accton Technology Corp 1997 All rights reserved Hardware Main Board Version 1 0 Firmware Main Board Version 1 0 Hardware Agent Module Version 2 0 Firmware Agent Module Version...

Страница 5: ...n the following sections Changing the System Configuration Use the System Configuration screen to display and modify descriptive information about the switch or to configure the switch s Internet Prot...

Страница 6: ...o Previous Menu Return to Main Menu Use cursor keys to choose item Press ENTER to confirm choice Press CTRL N to return to the Main Menu Community Strings Index Community Names Mode 1 public Read Writ...

Страница 7: ...Yes No No No No No No 6 No Yes No No No No No No 7 No Yes No No No No No No 8 No Yes No No No No No No Return to Previous Menu Return to Virtual LAN Configuration Screen Use cursor keys to choose item...

Страница 8: ...nt free cut through for a higher error rate and then to store and forward for a highly contentious environment To ensure that you can manage any network load without manual intervention adaptive cut t...

Страница 9: ...the priority for the use of a port in the STA algorithm If the path cost for all ports on a switch are the same the port with the highest priority i e lowest value will be configured as an active lin...

Страница 10: ...displayed have been accumulated since the last system reboot or counter reset Use the command options provided by the menu bar at the bottom of the screen Select Display to view statistics for each in...

Страница 11: ...100Mbps Port speed is automatically set to match the speed of the attached device Duplex1 Shows if the port is currently operating at full duplex or half duplex AgingTime1 Time in seconds after which...

Страница 12: ...n the designated bridging device through which this switch must communicate with the root of the spanning tree Downloading System Software Using TFTP Protocol to Download over the Network Use the TFTP...

Страница 13: ...nnections DB9 Serial Port Pin Description The DB9 serial port on the SwitcHub rear panel is used to connect the switch to a management device The on board menu driven configuration program can be acce...

Отзывы: