Accton Technology Fast SwitcHub-8mi SNMP Скачать руководство пользователя страница 10

Advanced Reference Guide

14

15

Fast SwitcHub-8mi SNMP

Displaying Statistics and Configuration Data

Displaying a Description of the Switch

Use the System Information screen to display descriptive information about the switch, or

for quick system identification.  This screen is detailed in the figure below and the following

table describing the displayed parameters:

                              System Information

    System Description            Intelligent Fast Ethernet Switch

    MAC Address                   00:00:E8:44:20:04

    Interface Description         Accton MPX2 Ver 1.0

    System Name                   Fast SwitcHub-8mi SNMP

    System Location               MIS

    System Contact                Accton Technical Support Dept.

    System Up Time                19Day, 2Hr, 41Min, 5Sec

    No of Reset Since Power On    1

    Return to Previous Menu

                              Return to Main Menu

        Use cursor keys to choose item. Press <ENTER> to confirm choice.

                  Press <CTRL><N> to return to the Main Menu

Parameter

Description

System Description

System hardware description.

MAC Address

Hardware address for the switch.

Interface Description

Firmware name and version used in transceiver chips.

System Name

Name assigned to the switch system (maximum 30 characters).

System Location

Specifies the area or location where the system resides (maximum 30

characters).

System Contact

Contact person for the system (maximum 30 characters).

System Up Time

Length of time the switch management agent has been running.

No. of Reset Since Power On Number of times the switch has been reset.

Displaying Switch and Port Statistics

Use the Statistics screen to display key statistics for each port or the whole switch.  The

Statistics screen displays overall statistics on the traffic passing through each port, as well

as the number of currently active stations.  This information can be used to identify potential

problems with the switch (e.g., a faulty port). The values displayed have been accumulated

since the last system reboot or counter reset.
Use the command options provided by the menu bar at the bottom of the screen.  Select

"Display" to view statistics for each individual port or the whole switch, or "Refresh" to

update the displayed statistics from the MIB.  Statistical values displayed by this screen are

indicated in the following figure and table.

                                  Statistics

Time Since Last Reset Port 1 Statisitcs:       11Day 10Hr 30Min 30Sec

No of Reset Port 1 Statistics Since Power On:  1

Local Frames Received     3244        CRC Errors                   205

Forwarded Frames          1234        Input Queue Frame Lost       0

Learning Broadcast Frames 12          Output Queue Frame Lost      0

Long Frames               39          No of Frames in Input Queue  20

Short Frames              19          No of Frames in Output Queue 6

Collisions                205         Currently Active Stations    86

        Return       Display       Refresh Screen      Reset Statistics

                              Return to Main Menu

        Use cursor keys to choose item. Press <ENTER> to confirm choice.

                  Press <CTRL><N> to return to the Main Menu

Name

Description

Local Frames Received

Number of frames confined to this segment and not forwarded by the

switch.

Forwarded Frames

Number of frames forwarded to another segment.

Learning Broadcast Frames

Number of learning broadcast frames received on this port.

Long Frames

Number of times frame length has exceeded the maximum allowable

size (i.e., 1518 bytes).

Short Frames

Number of frames less than 64 bytes long.

Collisions

Number of simultaneous node transmissions detected by this port.

CRC Errors

Number of CRC errors.

Input Queue Frame Lost

Number of frames lost because the input queue is full.

Output Queue Frame Lost

Number of frames lost because the output queue is full.

No. of Frames in Input Queue

Number of frames in the input queue.

No. of Frames in Output Queue Number of frames in the output queue.
Currently Active Stations

Number of entries in the address table (i.e., the sum of all stations listed

by this port, regardless of whether they belong to the local segment or to

another segment).

Содержание Fast SwitcHub-8mi SNMP

Страница 1: ...Fast SwitcHub 8mi SNMP Advanced Reference Guide ES3508 TX E0398 R01 150849 101...

Страница 2: ...he information in this document is subject to change without notice Accton reserves the right to make revisions to this publication without obligation to notify any person or entity of any such change...

Страница 3: ...ollowing tasks Enable disable any port Set the communication mode for any port Set the switching mode Configure SNMP parameters Configure VLAN port grouping Enable and configure the Spanning TreeAlgor...

Страница 4: ...Hub 8mi SNMP c Copyright Accton Technology Corp 1997 All rights reserved Hardware Main Board Version 1 0 Firmware Main Board Version 1 0 Hardware Agent Module Version 2 0 Firmware Agent Module Version...

Страница 5: ...n the following sections Changing the System Configuration Use the System Configuration screen to display and modify descriptive information about the switch or to configure the switch s Internet Prot...

Страница 6: ...o Previous Menu Return to Main Menu Use cursor keys to choose item Press ENTER to confirm choice Press CTRL N to return to the Main Menu Community Strings Index Community Names Mode 1 public Read Writ...

Страница 7: ...Yes No No No No No No 6 No Yes No No No No No No 7 No Yes No No No No No No 8 No Yes No No No No No No Return to Previous Menu Return to Virtual LAN Configuration Screen Use cursor keys to choose item...

Страница 8: ...nt free cut through for a higher error rate and then to store and forward for a highly contentious environment To ensure that you can manage any network load without manual intervention adaptive cut t...

Страница 9: ...the priority for the use of a port in the STA algorithm If the path cost for all ports on a switch are the same the port with the highest priority i e lowest value will be configured as an active lin...

Страница 10: ...displayed have been accumulated since the last system reboot or counter reset Use the command options provided by the menu bar at the bottom of the screen Select Display to view statistics for each in...

Страница 11: ...100Mbps Port speed is automatically set to match the speed of the attached device Duplex1 Shows if the port is currently operating at full duplex or half duplex AgingTime1 Time in seconds after which...

Страница 12: ...n the designated bridging device through which this switch must communicate with the root of the spanning tree Downloading System Software Using TFTP Protocol to Download over the Network Use the TFTP...

Страница 13: ...nnections DB9 Serial Port Pin Description The DB9 serial port on the SwitcHub rear panel is used to connect the switch to a management device The on board menu driven configuration program can be acce...

Отзывы: