Accton Technology Fast SwitchHub-8mi SNMP Скачать руководство пользователя страница 3

Advanced Reference Guide

Fast SwitcHub-8mi SNMP

1

Contents

Introduction

1

Making the Connections Required for System Configuration

1

Onsite Connection

1

Modem Connection

1

Telnet Connection

2

In-Band Network Connection

2

Configuring Your System with the On-Board Program

2

Using the System Configuration Program

3

Performing Basic Configuration

4

Changing the System Configuration

4

Assigning SNMP Parameters

6

Changing System Passwords

8

Port Grouping Configuration

8

Configuring Port Parameters

9

Using the Spanning Tree Algorithm

10

Configuring the Out-of Band Console

13

Displaying Statistics and Configuration Data

14

Displaying a Description of the Switch

14

Displaying Switch and Port Statistics

14

Displaying the Address Table

16

Displaying Port Status

16

Viewing the Current Spanning Tree Configuration

17

Downloading System Software

18

Using TFTP Protocol to Download over the Network

18

Using the Serial Port to Download Out-of-Band

19

Resetting the System

19

Logging Off the System

20

Troubleshooting

20

Telnet Access

20

Pin Assignments for Serial Port Connections

20

DB9 Serial Port Pin Description

20

DB9 Port Pin Assignments

21

Connecton from Switch’s 9-Pin Serial Port to PC’s 9-Pin COM Port

21

Connecton from Switch’s 9-Pin Serial Port to Modem’s25-Pin DCE Port

21

Connecton from Switch’s 9-Pin Serial Port to PC’s 25-Pin DTE Port

21

Introduction

The on-board management agent in the Fast SwitcHub-8mi SNMP provides the switch

with advanced management capabilities.  The SwitcHub’s SNMP agent module includes

a menu-driven configuration program that can be accessed by connecting a terminal or

PC to the serial port on the rear panel.  You can also access the configuration program

by an in-band Telnet connection, or perform in-band management from any network

management station running SNMP management software (e.g., AccView/Open).
The on-board configuration program allows you to perform the following tasks:

•

Enable/disable any port

•

Set the communication mode for any port

•

Set the switching mode

•

Configure SNMP parameters

•

Configure VLAN port grouping

•

Enable and configure the Spanning Tree Algorithm

•

Restart the system

Making the Connections Required for System Configuration

The SwitcHub provides a menu-driven configuration program.  Also the SNMP agent

allows you to manage the switch from any PC attached to the network using in-band

network management software (e.g., AccView/Open).

Note:

Limited configuration (i.e., selecting the port transmission mode) and panel

display selection can be carried out with the Configure button on the front panel.

(Refer to the Quick Installation Guide.)

This section describes how to access the menu-driven configuration program via:

•

Onsite connection

- A terminal or workstation directly connected to the serial port

on the switch.

•

Modem connection

- A workstation connected to a remote SwitcHub via modems.

•

Telnet connection

- A workstation connected to a remote SwitcHub via a network

Telnet connection.

It also describes how to access the on-board SNMP agent over the network from a

network management station (NMS) using network management software.

Onsite Connection

Attach a VT100 compatible terminal or a PC running a terminal emulation program to the

serial port on the SwitcHub’s rear panel.  Use the null-modem cable provided with the

product package, or use a null modem cable that complies with the wiring assignments

shown in the back of this guide.
When attaching to a PC, set terminal emulation type to VT100, specify the port used by

your PC (i.e., COM 1~4), and then set communications to 8 data bits, 1 stop bit, no

parity, and 9600 bps.  Also be sure to set flow control to "none."

Modem Connection

Configure the SwitcHub Site: Connect the switch's DB9 port to the modem's serial port

using standard cabling.  For most modems which use a 25-pin port, you will have to

provide an RS232 cable with a 9-pin connector on one end and a 25-pin connection on

the other end.  You do not have to set the modem at the switch's site, because the

switch will automatically configure it to auto-answer mode.

All manuals and user guides at all-guides.com

Содержание Fast SwitchHub-8mi SNMP

Страница 1: ...Fast SwitcHub 8mi SNMP Advanced Reference Guide ES3508 TX E0398 R01 150849 101 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 2: ... document is subject to change without notice Accton reserves the right to make revisions to this publication without obligation to notify any person or entity of any such changes International Headquarters USA Headquarters No 1 Creation Road III 1962 Zanker Road Science based Industrial Park San Jose CA 95112 Hsinchu 300 Taiwan R O C Phone 408 452 8900 Phone 886 3 5770 270 FAX 408 452 8988 FAX 88...

Страница 3: ...disable any port Set the communication mode for any port Set the switching mode Configure SNMP parameters Configure VLAN port grouping Enable and configure the Spanning TreeAlgorithm Restart the system Making the Connections Required for System Configuration The SwitcHub provides a menu driven configuration program Also the SNMP agent allows you to manage the switch from any PC attached to the net...

Страница 4: ...ht Accton Technology Corp 1997 All rights reserved Hardware Main Board Version 1 0 Firmware Main Board Version 1 0 Hardware Agent Module Version 2 0 Firmware Agent Module Version 1 2 Password Type password then press ENTER If this is your first time to log into the configuration program then the default passwords are still admin and guest The admin password provides administrator rights with Read ...

Страница 5: ...ns Changing the System Configuration Use the System Configuration screen to display and modify descriptive information about the switch or to configure the switch s Internet Protocol IP parameters This screen as seen below is described in the following table System Configuration System Name Fast SwitcHub 8mi SNMP System Location MIS System Contact Accton Technical Support Dept IP Address 192 72 24...

Страница 6: ...u Use cursor keys to choose item Press ENTER to confirm choice Press CTRL N to return to the Main Menu Community Strings Index Community Names Mode 1 public Read Write Return Add Entry Delete Entry Change Entry Clear Entry Return to SNMP Configuration Screen Use cursor keys to choose item Press ENTER to confirm choice Press CTRL N to return to the Main Menu Trap Receivers Index IP Address Communit...

Страница 7: ...6 No Yes No No No No No No 7 No Yes No No No No No No 8 No Yes No No No No No No Return to Previous Menu Return to Virtual LAN Configuration Screen Use cursor keys to choose item Press ENTER to confirm choice Press CTRL N to return to the Main Menu Parameter Description Port Port number on the switch Group1 8 You can configure up to a maximum of 8 independent groups Ports can belong to more than o...

Страница 8: ...r a higher error rate and then to store and forward for a highly contentious environment To ensure that you can manage any network load without manual intervention adaptive cut through is used as the default switching method By using this method the SwitcHub delivers the best network performance under any environment Using the Spanning Tree Algorithm The Spanning TreeAlgorithm i e the STAconfigura...

Страница 9: ...use of a port in the STA algorithm If the path cost for all ports on a switch are the same the port with the highest priority i e lowest value will be configured as an active link in the spanning tree Where more than one port is assigned the highest priority the port with lowest numeric identifier will be enabled The range is 0 255 Parameter Default Description continued Path Cost 10 or 100 This p...

Страница 10: ...cumulated since the last system reboot or counter reset Use the command options provided by the menu bar at the bottom of the screen Select Display to view statistics for each individual port or the whole switch or Refresh to update the displayed statistics from the MIB Statistical values displayed by this screen are indicated in the following figure and table Statistics Time Since Last Reset Port...

Страница 11: ...y set to match the speed of the attached device Duplex1 Shows if the port is currently operating at full duplex or half duplex AgingTime1 Time in seconds after which unused addresses will be discarded from the port s address table Switching Mode1 Shows the method used for forwarding packets as cut through fragment free cut through adaptive cut through or store and forward See Switching Methods 0n ...

Страница 12: ...ing device through which this switch must communicate with the root of the spanning tree Downloading System Software Using TFTP Protocol to Download over the Network Use the TFTP Download screen under the Download Reset menu to load software updates into the switch The download file should be an ES3508 bin file from Accton otherwise the agent will not accept it The success of the download operatio...

Страница 13: ...ort Pin Description The DB9 serial port on the SwitcHub rear panel is used to connect the switch to a management device The on board menu driven configuration program can be accessed from a terminal a PC running a terminal emulation program or from a remote location via a modem connection You can use the management port to configure port settings e g enabled or disabled or to update device firmwar...