background image

32

TEMPERATURE SENSOR R-T CONVERSION TABLE 

Only use for the solar temp sensor (T6) 

25=50KΩ±1.0

     

25/50 = 3950K±1.0

 

R(cent) 

R(cent) 

R(cent) 

R(cent) 

-20

466.6 

15 

78.38 

50 

17.93 

85 

5.227 

-19

441.1 

16 

74.85 

51 

17.26 

86 

5.061 

-18

417.2 

17 

71.5 

52 

16.61 

87 

4.902 

-17

394.7 

18 

68.32 

53 

15.99 

88 

4.748 

-16

373.5 

19 

65.29 

54 

15.4 

89 

4.6 

-15

353.6 

20 

62.41 

55 

14.83 

90 

4.457 

-14

334.8 

21 

59.68 

56 

14.29 

91 

4.319 

-13

317.2 

22 

57.07 

57 

13.77 

92 

4.188 

-12

300.6 

23 

54.6 

58 

13.27 

93 

4.058 

-11

284.9 

24 

52.24 

59 

12.79 

94 

3.935 

-10

270.2 

25 

50 

60 

12.33 

95 

3.815 

-9

256.3 

26 

47.86 

61 

11.89 

96 

3.7 

-8

243.1 

27 

45.83 

62 

11.46 

97 

3.589 

-7

230.7 

28 

43.89 

63 

11.06 

98 

3.482 

-6

219 

29 

42.05 

64 

10.67 

99 

3.378 

-5

208 

30 

40.28 

65 

10.29 

100 

3.278 

-4

197.6 

31 

38.61 

66 

9.936 

101 

3.182 

-3

187.7 

32 

37.01 

67 

9.591 

102 

3.088 

-2

178.4 

33 

35.49 

68 

9.259 

103 

2.998 

-1

169.6 

34 

34.03 

69 

8.941 

104 

2.911 

161.3 

35 

32.65 

70 

8.635 

105 

2.827 

153.4 

36 

31.32 

71 

8.341 

106 

2.746 

146 

37 

30.06 

72 

8.058 

107 

2.667 

139 

38 

28.85 

73 

7.786 

108 

2.591 

132.3 

39 

27.7 

74 

7.525 

109 

2.517 

126 

40 

26.6 

75 

7.247 

110 

2.446 

120 

41 

25.55 

76 

7.032 

111 

2.378 

114.3 

42 

24.54 

77 

6.8 

112 

2.311 

109 

43 

23.58 

78 

6.576 

113 

2.247 

103.9 

44 

22.66 

79 

6.361 

114 

2.184 

10 

99.04 

45 

21.78 

80 

6.153 

115 

2.124 

11 

94.47 

46 

20.94 

81 

5.954 

116 

2.065 

12 

90.12 

47 

20.14 

82 

5.762 

117 

2.009 

13 

86 

48 

19.37 

83 

5.577 

118 

1.955 

14 

82.09 

49 

18.64 

84 

5.398 

119 

1.902 

33

Содержание GREEN 500 S NEW

Страница 1: ...1 GREEN 500 S NEW Monobloc heat pump water heater with sanitary storage with additional exchangers GREEN 500 S NEW INSTALLATION MANUAL...

Страница 2: ...2 TABLE OF CONTENT 3 3 3 4 5 6 7 8 8 9 11 11 1 1 1 1 1 2 2 2 1 1 2 30 31 SPECIFICATION TEMPERATURE SENSOR CONVERSION TABLE J...

Страница 3: ...e experienced particularly in the humidseason Storage room cooling Units can be placed in the storage room as the low temperature keeps the food fresh Hot water and fresh air ventilation Units can be...

Страница 4: ...ncorrect operation due to ignoring of instructions may cause harm or damage Install the unit only when it complies with local regulations by laws and standards Check the main voltage and frequency Thi...

Страница 5: ...an injury due to possible fire electric shocks the unit falling etc Perform the installation securely and please refer to the installation instructions Incorrect installation could cause an injury due...

Страница 6: ...instruction If there is a defect in the drainage piping work water could leak from the unit and household goods could get wet and be damaged Do not clean the unit when the power is ON Always shut OFF...

Страница 7: ...S INSIDE PRODUCT BOX Before starting the installation please make sure that all parts are found inside the box The Unit Box Item Quantity Domestic hot water heat pump 1 Operation and Installation Manu...

Страница 8: ...scriptions 8 Parts and descriptions 1 000 Water tank Compressor Electronic expansion valve Evaporator 4 way valve Fan plate PCB Fan Controller Thermostat Switch Electrical box PCB for titaniumanode Tr...

Страница 9: ...c e l E t e l n i r a l o S t e l t u o r e t a w t o H C B A N O L M H D K F G E Lower tank water temp sensor 80 automatic reset protector 85 manual reset protector External Aluminum pipe Upper tank...

Страница 10: ...e water contained in the tank In case the titanium anode does not work correctly the error code E6 appears in the display of the Unit This unit has automatic disinfection cycle which starts every 7 da...

Страница 11: ...t it is done with care an inclination angle up to 30 degrees is permitted both during transport and storage Ambient temperatures of 20 to 70 degrees Celsius are permitted Transport using a forklift Wh...

Страница 12: ...connected portion airflow and capacity in heat pump unit willlose If the unit connects with air ducts it should be DN 180mm for pipes or 180mm internal diameter flexible hose Total length of the duct...

Страница 13: ...on sketch The discharge pipe connected to the one way safety valve is to be installed in a continuously downward direction and in a frost free environment 13 Domestic Hot Water T h e r m a l S o l a r...

Страница 14: ...t the tank is full Turn off all valves and check all pipes If any leakage please repair If the inlet water pressure is less than 0 15MPa a pressure pump should be installed at the water inlet For ensu...

Страница 15: ...very low outside temperatures during the winter 2 Hot water and dehumidification Units can be placed in the laundry room or clothing room When it produces hot water it lowers the temperature and dehum...

Страница 16: ...ent corrosion damage make sure that the materials used in the piping system are compatible 6 When installing the pipe work on the customers site any contamination of the piping system must be avoided...

Страница 17: ...ke sure that the power supply is normal and the wire connectionis ok Check the inlet water pressure make sure that the pressure is sufficient above 0 15Mpa Check if any water flows out from the hot wa...

Страница 18: ...power whole icons are displayed on the controller screen for 3 seconds After checking if everything is ok the unit enters into the standby mode 2 button Press this button and keep for 2 seconds when...

Страница 19: ...e clock setting interface hour and minute icons 88 88 flash together Short press button to switch hour minute setting press the and buttons to set the exact hour s and minute s Press button again to c...

Страница 20: ...em parameterchecking interface Pressthe and buttonsto check the system parameters 3 Adjust thesystem parameters 8 Error codes During standby or running status if there isamalfunction theunit will stop...

Страница 21: ...the fan will stop when the water temperature reaches the set point and unit is standby 3 Electrical heating The icon indicates that the electrical heating function is enabled The electrical heater wil...

Страница 22: ...3 Extra PV control function The new PV function has been added in the main control board it can be used to store energy in the tank in case of good solar insolation To enable the PV function it s nece...

Страница 23: ...mp disinfection TS3 Upper tank water temp 50 70 70 Adjustable 29 5 High temp disinfection time t2 0 90min 30min Adjustable 29 6 Defrosting period t3 30 90min 45min Adjustable 76 7 Temp to enter defros...

Страница 24: ...eturn water pump 1 15 2 Adjustable 29 17 Temperature difference to start solar water pump 5 20 5 Adjustable 29 18 Temperature difference to stop solar water pump 1 4 2 Adjustable 29 19 E heater or hea...

Страница 25: ...p setting temperature control 0 1 0 0 TS1 Real value 1 TS1 Manual value 76 30 Compensation temperature 10 10 0 Adjustable 76 31 The sampling period of Ambient temperature 2 120min 15min Adjustable 76...

Страница 26: ...mp sensor failure P3 3 flashes 1 dark Suction temp sensor failure P4 4 flashes 1 dark Ambient temp sensor failure P5 5 flashed 1dark Return water solar water tank temp sensor failure P6 Bright Emergen...

Страница 27: ...make sure the electrical components are good and the wiring is well If there is a damaged part or a strange smell please replace it in time If the heat pump is not used for a long time please drain o...

Страница 28: ...his equipment contains fluorinated greenhouse gases covered by the Kyoto Protocol It should only be serviced or dismantled by professional trained personnel This equipment contains R134a refrigerant i...

Страница 29: ...29 c or control board electronic anode T6 WIRING DIAGRAM GREEN 500 S NEW Additionally the sensor T6 shall be connected The load connect the...

Страница 30: ...30 4501 HEA 0 2 0 94 02 4 4 2 0 2 0 0 Model 4 2 20 2 2009 4 2 2 40 2 GREEN 500 S NEW U M Model TECHNICAL DATA TABLE GREEN 500 S NEW...

Страница 31: ...5 38 3 037 3 082 3 128 79 0 796 0 819 0 842 2 15 231 15 561 15 896 39 2 929 2 974 3 019 80 0 773 0 795 0 818 1 14 559 14 867 15 18 40 2 826 2 87 2 915 81 0 751 0 773 0 795 0 13 92 14 208 14 501 41 2 7...

Страница 32: ...7 3 589 7 230 7 28 43 89 63 11 06 98 3 482 6 219 29 42 05 64 10 67 99 3 378 5 208 30 40 28 65 10 29 100 3 278 4 197 6 31 38 61 66 9 936 101 3 182 3 187 7 32 37 01 67 9 591 102 3 088 2 178 4 33 35 49 6...

Страница 33: ...33...

Страница 34: ...34...

Страница 35: ...35...

Страница 36: ...itolo puramente indicativo la A2B Accorroni E G S r l si riserva di apportare eventuali modi che senza alcun preavviso web site www accorroni it e mail a2b accorroni it A2B Accorroni E G s r l Via d A...