SECTION B - TECHNICAL NOTES FOR THE INSTALLER
2. ATTENTION
2.1 2.1 INSTALLER QUALIFICATIONS
WARNING! Both the plumbing and electrical
parts of the installation must be carried out
by specialists, qualified under the terms of
law 46/'90, who can correctly perform the
operations specified in this manual.
2.2 PRELIMINARY INFORMATION
Before starting installation, ensure that the options
chosen and any plans made conform to the current
rules and regulations regarding heat generators
and/or cooling systems for use in the plant.
As examples, the following are some of the
present provisions:
- a technical report must be compiled with regard
to the provisions in force for energy savings in
new buildings. Art. 28 of law 9 of January 1991,
no. 10.
- a plan must be produced for plants in public
buildings using combustible gas with a heat
potential >35 kW (30,000 kcal/h) or for air
conditioning plants with cooling potential>
40,000 frig/h (46.5 kW).
- There must be a check on the installation in
relation to the electrical wiring of locales
according to EIC norms of electrical safety (for
example in places where there is a bath or
shower).
The relevant technical regulations and
legislation are:
- Law 5 March 1990, no. 46 "regulations for
safety of plants", published in G.U. no. 59 of 12/
3/90.
- D.P.R. 6/12/91 no. 447 "Regulating
implementation of law 5 of March 1990, no.
46, with respect to safety of plants", published
in G.U. no. 38 of 15/2/92.
- Regulation UNI-CTI 10344, '93 edition, "Heating
in buildings - energy use calculations".
To ensure conformity with all the above, use
a qualified central heating engineer who can
guarantee correct compliance and execution
of all necessary operations.
2.3 TRANSPORT AND HANDLING
The fan heater comes in a standard cardboard
pack with internal expanded polystyrene or
cardboard protective packing. The pack may be
moved manually or by forklift, taking care to
respect the signs on the cardboard box with their
appropriate symbols.
Where there are multiple packs on pallets, move
with a forklift which is designed for the weight and
size of the pack and do not force or distort the
box. Respect safety regulations while moving
the load.
Place the packs vertically on top of each other up
to the maximum number shown on the packs.
WARNING! Maximum weight for one person
alone to lift is 30 kg.
On taking delivery, ensure that there has been no
visible damage to the pack and/or to the appliance
during transport. Where there is any damage,
make an immediate formal complaint to the
transporter. Do not install appliances damaged
during transport.
Any storage premises must have stable flooring,
must not be damp and must be free from air
pollution (in warehouses prepare flooring
using pallets to support the packs in a dry,
sheltered place). Keep the packs in places
where no-one, even accidentally, can walk on
them or use them to put things on.
2.4 DATA CHECK
Check that the fan heater and its technical
characteristics conform with what was in the
plan or other specifications. The appliance
identification data is on a label in the back of the
unit on the right side of the frame.
2.5 USE OF INSTRUCTIONS
WARNING! When installing or working on
the appliance, follow all the instructions in
this manual. Any changes in connections
and/or any failure to respect the instructions
will immediately nullify the guarantee and
any manufacturer's responsibility.
Содержание FR-FC-FCO-FCR 100
Страница 1: ...Technical Information FR FC FCO FCR 100 800 Fan coil units series FR FC FCO FCR Models100 800...
Страница 9: ...pag 8 1 8 DETAILED VIEW Vertical FR version with cover Fig 3 modd 100 200...
Страница 10: ...pag 9 1 8 DETAILED VIEW Horizontal FC version with cover Fig 4 modd 100 200...
Страница 11: ...pag 10 1 8 DETAILED VIEW Vertical FCO version with casing Fig 5 modd 100 200...
Страница 12: ...pag 11 1 8 DETAILED VIEW Horizontal FCR version with casing Fig 6 modd 100 200...
Страница 32: ...pag 31...
Страница 33: ...Fan coil units series FR FC FCO FCR Technical details Cod 26209501 IT Rev 1 07 04 03...
Страница 34: ......