Accora CommunityBed Bed Lever Скачать руководство пользователя страница 3

 

 

 

1.

 

Safety Instructions 

 

1.

 

Before using the CommunityBed Bed Lever, you 
must read the manual and use this device in 
accordance with it. 

2.

 

The CommunityBed Bed Lever may not be used if 
faults have been detected on it that may injure 
the patient, staff or a third person, or damage the 
CommunityBed Bed Lever or the surroundings. 

3.

 

Before using the CommunityBed Bed Lever, the 
operator should understand its functionality. 

4.

 

When replacing missing parts, only original 
materials and components must be used. 

5.

 

Check that the Backrest or Legrest sections of the 
CommunityBed don’t collide with the Bed Lever 
when either section is raised or lowered. 

 

2.

 

Intended use 

 
The CommunityBed Bed lever is used to aid a person 
getting out of bed. 
 
This CommunityBed Bed Lever is intended for use in the 
following application environments only: 
 
1.

 

Application Environment 3 - Long-term care in a 
medical area where medical supervision is 
required and monitoring is provided if necessary 
and ME equipment used in medical procedures 
may be provided to help maintain or improve the 
condition of the patient. Note, this includes use in 
nursing homes and in rehabilitation and geriatric 
facilities. 

2.

 

Application Environment 4 - Care provided in a 
domestic area where ME equipment is used to 
alleviate or compensate for an injury, disability or 
disease 

 
It is essential to consult Accora in advance if you wish 
to use the CommunityBed Bed Lever for any purpose 
outside the use detailed in this manual. 
 
Note: the Bed Lever cannot be fitted to a 
CommunityBed which already has siderails fitted. 
 

 

GENERAL WARNINGS 
 

1.

 

Keep this Instruction Manual available for 
future reference. 

2.

 

These instructions must be observed to 
ensure the safe and effective use of this 
CommunityBed Bed Lever and the safety 
of users, carers and those around. 

3.

 

The CommunityBed Bed Lever must be 
fitted, positioned and used in accordance 
with these instructions. 

4.

 

The safety features for using the 
CommunityBed Bed Lever and instructions 
for use must be strictly observed.

 

5.

 

The CommunityBed Bed Lever must not be 
exposed to smoke, naked flame, extreme 
temperature, flammable gases or other 
hazardous substances or situations.

 

6.

 

Accora shall not be held liable for any 
damage, injuries or accidents arising from 
unauthorised modifications, non-genuine 
spare parts, negligence or use that is at 
variance with this manual.

 

7.

 

When routing cables for other electrical 
equipment used with the bed (e.g. air 
mattress pump), ensure cables cannot be 
squeezed, crushed or damaged by the 
CommunityBed Bed Lever. 

8.

 

Never stand on the CommunityBed Bed 
Lever.  

9.

 

Never attach anything to the 
CommunityBed Bed Lever. 

10.

 

Do not move the bed by pulling or 
pushing on the CommunityBed Bed Lever. 

11.

 

Do not modify this CommunityBed Bed 
Lever. 

12.

 

Patients, or users, should be risk assessed to 
ensure they understand this manual and 
can use the CommunityBed Bed Lever 
safely without risk to themselves or others. 

13.

 

Accora shall not be held liable for any 
damage, injuries or accidents arising from 
negligence or use that is at variance with 
this manual. 

14.

 

The safety features for using the 
CommunityBed Bed Lever, and 
instructions concerning this item must be 
observed. 

15.

 

The CommunityBed Bed Lever is not a Side 
rail and must not be used in place of a 
Side rail. The CommunityBed Bed Lever is 
an aid. 

 

Содержание CommunityBed Bed Lever

Страница 1: ...CommunityBed Bed Lever Instruction Manual IFU CB1 002EN REV 01 SEPTEMBER 2017...

Страница 2: ...01223 206120 E mail info accora uk com General This CommunityBed accessory is classified as a Medical Device Class 1 in accordance with the European Medical Device Directive 93 42 EEC This instruction...

Страница 3: ...fitted GENERAL WARNINGS 1 Keep this Instruction Manual available for future reference 2 These instructions must be observed to ensure the safe and effective use of this CommunityBed Bed Lever and the...

Страница 4: ...s injury Zone B ONLY fit the CommunityBed Bed Lever in this zone Zone C DO NOT fit the CommunityBed Bed Lever in this zone Fitting in this zone may cause an entrapment risk resulting in serious injury...

Страница 5: ...on 4 5 Clamp the CommunityBed Bed Lever to the frame of the Community Bed with the bolts washers and nuts Tighten the nuts and bolts with the 13mm spanner 6 Cap the head of the bolt with the bolt cap...

Страница 6: ...recommend 1 CommunityBed Bed Lever should be stored in a temperature between 20 C to 50 C 4 F to 122 F 2 CommunityBed Bed Lever should be stored in a relative humidity non condensing between 30 and 7...

Страница 7: ...Complies with the European Medical Device Directive 93 42 EEC Model number Serial number Manufactured date Manufacturer Safe Unsafe Manufacturer s nameplate Entrapment warning label Bed Lever positio...

Страница 8: ...8 IFU CB1 002EN REV 01 SEPTEMBER 2017...

Отзывы: