During cleaning, the stove must be cold, you must not heat in it, and 
there may not be any hidden hot coal in it (even in the ash)!!! 

 

 

 

 
 

 

Should several appliances are connected to the chimney, either on one floor 
or several floors, take such precautions prior to cleaning that would be in 
accordance with the local legal standards of the country as well as the fire 
and safety precautions. 

 

 
 
 

 
 

 

When cleaning the stove, use the personal protective aids, namely: 
goggles, clothes, shoes, gloves and respirator, washing agent for skin, 
clean cloth for wiping hands, etc. 

 
 
 

 

The safe and efficient operation of the stove shall be achieved through the regular inspection, 
maintenance  and  cleaning  of  the  stove,  as  well  as  the  following  of  the  complete  Operation 
Manual  and  safety  regulations.  The  cleaning  and  regular  maintenance  of  the  stove  must  be 
carried out by the competent technician at least once a year. 

Aids for stove cleaning: 

 

Vacuum cleaner for collecting ash and carbon particles, 

 

Hand-held steel brush, 

 

Chimney sweeper with a extension piece (the minimal length of the extension piece 

should be selected according to the length of the connected fume duct of the stove to 
the chimney), 

 

Small broom and scoop, 

 

Larger metal container with a lid for collecting carbon particles and contaminants from 
the stove, 

 

The blinding metal bottom with the diameter of the connected fume duct of the stove to 
the chimney, 

 

Torch. 

We recommend you to let the work be done by an experienced trained serviceman.  The stove 
cleaning is rather simple and fast. 

The cleaning of the interior area of the stove and fume duct should be carried out once a years 

Содержание SAHARA Type I.

Страница 1: ...SAHARA CAST IRON STOVE Operation Manual and Warranty Certificate ACCONT s r o SK Pod H jom 1367 168 018 41 Dubnica nad V hom www liatinove kachle sk Type I Type II Type III Type IV Type V...

Страница 2: ......

Страница 3: ...1 2 3...

Страница 4: ...n at Nominal Power and Heating up 12 The Oven Operation at Reduced Power 13 Stove Operation Termination 14 Important Warnings 15 INSPECTION CLEANING MAINTENANCE AND REPAIRS OF STOVE 17 Stove Inspectio...

Страница 5: ...u make a lot for letting your stove please the heart and eyes of you and your ancestors for many generations The environment friendly character of our stoves lies in two main levels The current and fu...

Страница 6: ...ower 10 Pa Chimney connection diameter 110 mm Diameter of a tube connected to the chimney 130 mm Chimney temperature 149 C The height up to the bottom edge of neck for chimney connector 1 135 mm Heigh...

Страница 7: ...power 10 Pa Chimney connection diameter 110 mm Diameter of a tube connected to the chimney 130 mm Chimney temperature 149 C The height up to the bottom edge of neck for chimney connector 1 135 mm Heig...

Страница 8: ...power 10 Pa Chimney connection diameter 110 mm Diameter of a tube connected to the chimney 130 mm Chimney temperature 169 C The height up to the bottom edge of neck for chimney connector 830 mm Heigh...

Страница 9: ...power 10 Pa Chimney connection diameter 110 mm Diameter of a tube connected to the chimney 130 mm Chimney temperature 169 C The height up to the bottom edge of neck for chimney connector 830 mm Heigh...

Страница 10: ...power 10 Pa Chimney connection diameter 110 mm Diameter of a tube connected to the chimney 130 mm Chimney temperature 189 C The height up to the bottom edge of neck for chimney connector 530 mm Heigh...

Страница 11: ...or cleaning 1 pc Cement 1 pc Hand held cement press 1 pc Refractory cloth with Al layer 1 pc Refractory parts for the grate 4 pcs Refractory curved segments 6 pcs Heat resistant apron to be used at th...

Страница 12: ...ould be carried out minimally by two adult persons since it is required by the weight of the stove Find a place where the stove shall be installed Check for the rigidity of the structure under the sto...

Страница 13: ...ted to the chimney with the required parameters The cross section of the chimney should be minimally of 150 mm diameter and its height should be minimally 5 m It is recommended for a good performance...

Страница 14: ...nd metal sheets The distance between the flammable object and the protecting board the clean air gap must be minimally 25 mm in order to avoid the risk of fire As long as there are the objects made fr...

Страница 15: ...C3 EASILY FLAMMABLE Particleboards laminated sawdust and sawdust particle boards sawdust boards pilolamit Particleboards akulit bukolamit bukolit hobra sololit Boards made fro plant matters cork board...

Страница 16: ...minutes first heating in the stove Then let the stove slowly cool down FUEL The stove was designed for the combustion of wooden split and whole logs of a reasonable circumference up to ca 28 cm dried...

Страница 17: ...bustion air shall remain in MAX position the flame must be still The wood can be loaded to the stove in horizontal askew position as well as vertically The procedure of air adjustment must be repeated...

Страница 18: ...terminate the adjustment of secondary air Fig 1 position e Such heated up stove can heat for approx 12 hours depending on the type of the stove heating and weather conditions The fuel doses shall be...

Страница 19: ...order to prevent the breach of any stove part on the cemented connections Furthermore nothing can lean on the stove even when it is cold It is also forbidden to manipulate with the stove parts during...

Страница 20: ...n of fuel in the stove till the complete burning out of the fuel and the extinguishing of all hot coals in the stove including the ash can and at the same time the cooling down of the entire surface o...

Страница 21: ...xpert trained by the manufacturer of the stove as soon as possible at first then follow his her instructions If it is impossible to contact him her do not continue in the activity or situation INSPECT...

Страница 22: ...nge colour and the fume coming out of the chimney should be pale You shall thus avoid killing of humans and animals by suffocation CO2 and fume killing of humans and animals by poisonous gas CO that c...

Страница 23: ...g of the complete Operation Manual and safety regulations The cleaning and regular maintenance of the stove must be carried out by the competent technician at least once a year Aids for stove cleaning...

Страница 24: ...risk of property and surroundings damage by fire STOVE CLEANING AND MAINTENANCE We recommend regular inspection cleaning maintenance and possible repairs of the stove to be done by the competent emplo...

Страница 25: ...d interior section of the stove remember to clean the area of the stove connection to fume duct Gross contaminants on the internal wall of the stove should be removed using a steel brush If necessary...

Страница 26: ...m up downwards Non patinated stove is to be gently polished using soft cloth flannel suede wool b Complete bronze patinated stove is to be gently brushed using brass brush mainly its bronze parts unti...

Страница 27: ...on if damaged or pressed out if there is a fumed spot on the surface of the stove anywhere around the seal In the case the seal replacement is necessary call the relevant authorised servicing organisa...

Страница 28: ...3 hereof shall apply only supposing that The stove was installed assembled and put into operation by the authorised serviceman which is proved by the drawn and acknowledged protocol kept by the releva...

Страница 29: ...stipulation of Article 616 of the Civil Code as the conflict with the purchase contract In the remaining months of warranty period of the stove the process shall depend upon the fact whether there is...

Страница 30: ...26 NOTES...

Страница 31: ...27 CONTACT DATA SERVICE Address ACCONT s r o Pod H jom 1367 168 018 41 Dubnica nad V hom SK E mail Web kachlesahara gmail com www liatinove kachle sk...

Страница 32: ...28...

Отзывы: