background image

-17- 

 

and to the proximity of the stove, when the stove is hot or cold! 

-

 

Never let the stove in operation without a responsible supervision. 

-

 

The  refractory  concrete  segments may  have  the  protruding  stainless  steel wire on 

their  surface,  it  might  hurt  your  skin  by  unpleasant  scratching,  piercing,  cutting, 
especially in the case of segments damaged by unsuitable transport, storage, etc. or 
worn and cracked segments when carrying out maintenance, cleaning and repairs of 
the stove. 

-

 

In case  of open fire,  immediately  cover  the  flames  with the  fire  blanket. Thus you 

will  prevent  the  fire  from  spreading!!!  Fire  blanket  is  part  of  the  delivery  of  each 
type of cast-iron stove SAHARA.  Always have the fire blanket ready and store it at 
hand on a suitable place. 

-

 

If you are not sure during any activity or in any situation with regards to the stove, 
after you had read the 

Operation Manua

l and fully understood and 

comprehended it, always for this purpose  contact the relevant servicing expert  
trained by the manufacturer of the stove as soon as possible at first, then follow 
his/her instructions. If it is impossible to contact him/her, do not continue in the 
activity or situation. 

 

 

INSPECTION, CLEANING, MAINTENANCE AND REPAIRS OF 
STOVE 

 
 
 

 

We recommend the regular inspection, cleaning, maintenance and 
possible repairs of the stove to be done by the competent employee 
of the relevant servicing organisation who is trained by the 
manufacturer of the stove, at least once a year. 

 
 
 

 

STOVE INSPECTION 

 

 

Regularly  inspect  the  interior  space  of  the  stove  through  inspection  hole  (Fig.  1  - 

position f),  the loading door (Fig. 1  -  position a) and ash-can door (Fig. 1  -  position b)  at  least 
once every 3 months. 

The inspection of the stove should be carried out continuously by monitoring the surface of the 
stove even when it is out of operation when no fuel is combusted. As long as any of the stove 
seals does not sufficiently fulfil its function, usually due to ending its operation life, it shall be 
usually  demonstrated  by  the  change  of  surface  colour  of  the  stove  on  the  spot  of  reduced 
tightness (fine deposits of carbon particles can be generated), there shall be the discolouration 

Содержание SAHARA Type I.

Страница 1: ...SAHARA CAST IRON STOVE Operation Manual and Warranty Certificate ACCONT s r o SK Pod H jom 1367 168 018 41 Dubnica nad V hom www liatinove kachle sk Type I Type II Type III Type IV Type V...

Страница 2: ......

Страница 3: ...1 2 3...

Страница 4: ...n at Nominal Power and Heating up 12 The Oven Operation at Reduced Power 13 Stove Operation Termination 14 Important Warnings 15 INSPECTION CLEANING MAINTENANCE AND REPAIRS OF STOVE 17 Stove Inspectio...

Страница 5: ...u make a lot for letting your stove please the heart and eyes of you and your ancestors for many generations The environment friendly character of our stoves lies in two main levels The current and fu...

Страница 6: ...ower 10 Pa Chimney connection diameter 110 mm Diameter of a tube connected to the chimney 130 mm Chimney temperature 149 C The height up to the bottom edge of neck for chimney connector 1 135 mm Heigh...

Страница 7: ...power 10 Pa Chimney connection diameter 110 mm Diameter of a tube connected to the chimney 130 mm Chimney temperature 149 C The height up to the bottom edge of neck for chimney connector 1 135 mm Heig...

Страница 8: ...power 10 Pa Chimney connection diameter 110 mm Diameter of a tube connected to the chimney 130 mm Chimney temperature 169 C The height up to the bottom edge of neck for chimney connector 830 mm Heigh...

Страница 9: ...power 10 Pa Chimney connection diameter 110 mm Diameter of a tube connected to the chimney 130 mm Chimney temperature 169 C The height up to the bottom edge of neck for chimney connector 830 mm Heigh...

Страница 10: ...power 10 Pa Chimney connection diameter 110 mm Diameter of a tube connected to the chimney 130 mm Chimney temperature 189 C The height up to the bottom edge of neck for chimney connector 530 mm Heigh...

Страница 11: ...or cleaning 1 pc Cement 1 pc Hand held cement press 1 pc Refractory cloth with Al layer 1 pc Refractory parts for the grate 4 pcs Refractory curved segments 6 pcs Heat resistant apron to be used at th...

Страница 12: ...ould be carried out minimally by two adult persons since it is required by the weight of the stove Find a place where the stove shall be installed Check for the rigidity of the structure under the sto...

Страница 13: ...ted to the chimney with the required parameters The cross section of the chimney should be minimally of 150 mm diameter and its height should be minimally 5 m It is recommended for a good performance...

Страница 14: ...nd metal sheets The distance between the flammable object and the protecting board the clean air gap must be minimally 25 mm in order to avoid the risk of fire As long as there are the objects made fr...

Страница 15: ...C3 EASILY FLAMMABLE Particleboards laminated sawdust and sawdust particle boards sawdust boards pilolamit Particleboards akulit bukolamit bukolit hobra sololit Boards made fro plant matters cork board...

Страница 16: ...minutes first heating in the stove Then let the stove slowly cool down FUEL The stove was designed for the combustion of wooden split and whole logs of a reasonable circumference up to ca 28 cm dried...

Страница 17: ...bustion air shall remain in MAX position the flame must be still The wood can be loaded to the stove in horizontal askew position as well as vertically The procedure of air adjustment must be repeated...

Страница 18: ...terminate the adjustment of secondary air Fig 1 position e Such heated up stove can heat for approx 12 hours depending on the type of the stove heating and weather conditions The fuel doses shall be...

Страница 19: ...order to prevent the breach of any stove part on the cemented connections Furthermore nothing can lean on the stove even when it is cold It is also forbidden to manipulate with the stove parts during...

Страница 20: ...n of fuel in the stove till the complete burning out of the fuel and the extinguishing of all hot coals in the stove including the ash can and at the same time the cooling down of the entire surface o...

Страница 21: ...xpert trained by the manufacturer of the stove as soon as possible at first then follow his her instructions If it is impossible to contact him her do not continue in the activity or situation INSPECT...

Страница 22: ...nge colour and the fume coming out of the chimney should be pale You shall thus avoid killing of humans and animals by suffocation CO2 and fume killing of humans and animals by poisonous gas CO that c...

Страница 23: ...g of the complete Operation Manual and safety regulations The cleaning and regular maintenance of the stove must be carried out by the competent technician at least once a year Aids for stove cleaning...

Страница 24: ...risk of property and surroundings damage by fire STOVE CLEANING AND MAINTENANCE We recommend regular inspection cleaning maintenance and possible repairs of the stove to be done by the competent emplo...

Страница 25: ...d interior section of the stove remember to clean the area of the stove connection to fume duct Gross contaminants on the internal wall of the stove should be removed using a steel brush If necessary...

Страница 26: ...m up downwards Non patinated stove is to be gently polished using soft cloth flannel suede wool b Complete bronze patinated stove is to be gently brushed using brass brush mainly its bronze parts unti...

Страница 27: ...on if damaged or pressed out if there is a fumed spot on the surface of the stove anywhere around the seal In the case the seal replacement is necessary call the relevant authorised servicing organisa...

Страница 28: ...3 hereof shall apply only supposing that The stove was installed assembled and put into operation by the authorised serviceman which is proved by the drawn and acknowledged protocol kept by the releva...

Страница 29: ...stipulation of Article 616 of the Civil Code as the conflict with the purchase contract In the remaining months of warranty period of the stove the process shall depend upon the fact whether there is...

Страница 30: ...26 NOTES...

Страница 31: ...27 CONTACT DATA SERVICE Address ACCONT s r o Pod H jom 1367 168 018 41 Dubnica nad V hom SK E mail Web kachlesahara gmail com www liatinove kachle sk...

Страница 32: ...28...

Отзывы: