Acconeer XE132 Скачать руководство пользователя страница 30

Entry module EVK hardware user guide 

   

 

 

 

Page 30 of 30 

 
 
© 2020 by Acconeer 

 All rights reserved 

 

2020-09-25 

7.  Disclaimer 

The 

information herein is believed to be correct as of the date issued. Acconeer AB (“

Acconeer

”) will 

not be responsible for damages of any nature resulting from the use or reliance upon the information 
contained herein. Acconeer makes no warranties, expressed or implied, of merchantability or fitness 

for a particular purpose or course of performance or usage of trade. Therefore, it is the user’s 

responsibility to thoroughly test the product in their particular application to determine its performance, 
efficacy and safety. Users should obtain the latest relevant information before placing orders.  

Unless Acconeer has explicitly designated an individual Acconeer product as meeting the requirement 
of a particular industry standard, Acconeer is not responsible for any failure to meet such industry 
standard requirements. 

Unless explicitly stated herein this document Acconeer has not performed any regulatory conformity 

test. It is the user’s responsibility to assure that necessary regulatory conditions are met and approvals 

have been obtained when using the product. Regardless of whether the product has passed any 
conformity test, this document does not co

nstitute any regulatory approval of the user’s product or 

application using Acconeer’s product. 

 

Nothing contained herein is to be considered as permission or a recommendation to infringe any 
patent or any other intellectual property right. No license, express or implied, to any intellectual 
property right is granted by Acconeer herein. 

Acconeer reserves the right to at any time correct, change, amend, enhance, modify, and improve this 
document and/or Acconeer products without notice.

  

This document supersedes and replaces all information supplied prior to the publication hereof. 

 

Acconeer AB 

 

www.acconeer.com 

IDEON Gateway 

[email protected] 

Scheelevägen 27 

+46 10 218 92 00 

223 63 LUND 
Sweden

 

Содержание XE132

Страница 1: ...Entry module EVK hardware user guide Entry module EVK hardware user guide XE132...

Страница 2: ...Entry module EVK hardware user guide Page 2 of 30 2020 by Acconeer All rights reserved 2020 09 25 Entry module EVK hardware user guide XE132 Author Acconeer Version 1 0 2020 08 31 Acconeer AB...

Страница 3: ...3 The EVK Hardware 6 3 1 XE132 Evaluation Board 9 3 1 1 Overview 9 3 1 2 Power 10 3 1 3 Not Mounted Components 10 3 1 4 Electrical Schematics 11 3 1 5 Bill of Material 15 3 1 6 Component Placement Dra...

Страница 4: ...CR It has leading edge patented sensor technology with pico second time resolution The A111 sets a new benchmark as far as power consumption and distance accuracy are concerned and it comes fully inte...

Страница 5: ...nloaded at the same site 2 2 SW API Description The Acconeer SW comes with an API Application Programming Interface Acconeer provides several service oriented example and reference applications as wel...

Страница 6: ...y module EVK hardware user guide Page 6 of 30 2020 by Acconeer All rights reserved 2020 09 25 3 The EVK Hardware In Figure 1 the block diagram of the XE132 is shown Figure 2 shows the XM132 block diag...

Страница 7: ...neer All rights reserved XM132 USB1 Connector 5V Boot0 NRST Button DFU Button XE132 V_EXT 1 8 3 6V GPIO pin header USB VIN 0 Ohm Power pin header VIN_XM132 USB UART converter CP2105 SWD connector NRST...

Страница 8: ...20 09 25 24MHz XTAL XM132 ENABLE INTERRUPT BOOT0 NRST SPI CTRL ENABLE INTERRUPT CTRL Power switch A111 PS_ENABLE STM32G071CBU6 Switched Power Regulator LC filter 1V8 Land Grid Array CPU 32 bit 64MHz C...

Страница 9: ...It makes the interfaces from the XM132 module accessible for evaluation and debug It also enables flashing of the XM132 via USB UART or SW DP The XM132 Entry module is included in the XE132 Evaluatio...

Страница 10: ...o measure only the current consumed by XM132 power should be supplied to XM132 via the pin VIN_XM132 in pin header J3 In this case R25 should be unmounted and S1 should be placed in position 3 3V This...

Страница 11: ...Entry module EVK hardware user guide Page 11 of 30 2020 09 25 2020 by Acconeer All rights reserved 3 1 4 Electrical Schematics On the following pages please find the Electrical Schematics for XE132...

Страница 12: ...Entry module EVK hardware user guide Page 12 of 30 2020 by Acconeer All rights reserved 2020 09 25...

Страница 13: ...Entry module EVK hardware user guide Page 13 of 30 2020 09 25 2020 by Acconeer All rights reserved...

Страница 14: ...Entry module EVK hardware user guide Page 14 of 30 2020 by Acconeer All rights reserved 2020 09 25...

Страница 15: ...cro USB 2 0 B Receptacle STD 10118194 0001LF 1 Manufacturer Amphenol R23 Chip Resistor 0402 5 33R 1 33Ohm R2 Chip Resistor 0402 5 24K 1 24kOhm U2 TVS Diode 30kV SOT143 4 SP0503BAHTG 1 Manufacturer Lit...

Страница 16: ...Entry module EVK hardware user guide Page 16 of 30 2020 by Acconeer All rights reserved 2020 09 25 3 1 6 Component Placement Drawing The component placement drawing of XE132 is found below Top Side...

Страница 17: ...USB J1 USB is used as power supply for the XB132 as well as for flashing and communicating over UART USB is connected to the Silicon Labs chip CP2105 which converts the UART interfaces from XM132 into...

Страница 18: ...nterface The pinout matches that of the Cortex 10 pin JTAG SWD Connector and is found in Table 4 Table 4 The pinout of J6 Pin Number Signal Pin Number Signal 1 VIN_XM132 2 SWD_IO 3 GND 4 SWD_CLK_BOOT0...

Страница 19: ...ignal on XM132 In Table 6 the state of the buttons and the corresponding signal states are listed Table 6 The states of the buttons J4 and J5 Button Open default Closed J4 BOOT 0 BOOT0 1 J5 NRESET 1 N...

Страница 20: ...Entry module EVK hardware user guide Page 20 of 30 2020 by Acconeer All rights reserved 2020 09 25 Electrical Schematics On the following pages please find the Electrical Schematics for XM132...

Страница 21: ...Entry module EVK hardware user guide Page 21 of 30 2020 09 25 2020 by Acconeer All rights reserved...

Страница 22: ...Entry module EVK hardware user guide Page 22 of 30 2020 by Acconeer All rights reserved 2020 09 25...

Страница 23: ...Entry module EVK hardware user guide Page 23 of 30 2020 09 25 2020 by Acconeer All rights reserved...

Страница 24: ...hip Resistor 0402 5 33R 1 33Ohm L1 IND1608 Inductors 2 2uH 20 500mA 1 2 2uH TDK MLZ1608N2R2LT000 L2 2520 2 2UH 20 40 125 C 1 2 2uH Abracon LLC ASMPH 1008 2R2M T Alternative Murata DFE252012P 2R2M P2 B...

Страница 25: ...igure 3 XM132 top side 3 2 4 Land Grid Array Pinning In Table 8 the LGA pinning U7 is shown Table 8 The pinning of the XM132 Land Grid Array Pin Number Signal Comment 1 VIN 1 8 3 6V typical 3 3V 2 Gro...

Страница 26: ...ll start the embedded boot loader 12 WAKE_UP Could be used by host to wake up XM132 MCU 13 Ground 14 I2C_SCL 15 I2C_SDA 16 NRESET Reset of XM132 MCU 17 Ground 18 MISC_GPIO2 19 MISC_GPIO0 20 Ground 21...

Страница 27: ...2020 09 25 2020 by Acconeer All rights reserved 4 Safety 4 1 Electrostatic precautions Please take electrostatic precautions including using ground straps when using the EVK or any of its components...

Страница 28: ...ory status it is the user s responsibility to ensure that any regulatory requirements applicable to any region are followed in the region the device is being used Regulatory Compliance for A111 The cu...

Страница 29: ...Entry module EVK hardware user guide Page 29 of 30 2020 09 25 2020 by Acconeer All rights reserved 6 Revision History Date Revision Changes 2020 08 31 1 0 Original version...

Страница 30: ...failure to meet such industry standard requirements Unless explicitly stated herein this document Acconeer has not performed any regulatory conformity test It is the user s responsibility to assure th...