background image

3

1 .Remove

 

the

 

existing

3.Route  

the  

light  control’

s wires

 

through

 

the large gasket  holes.

4.Twist  the

 

junction

 

box

 

wires and

wires

 

together as

 

shown.

 

Secure

 

with

 

wire

 

connectors.

White

 to 

White

Black

 to 

Black

Junction box ground wire to 
green ground screw on 

xture.

Gasket

Mounting  

Strap

Mounting

 

Bolt

Rubber

 

Plug

Install the Light 

1.Align the light

  control

  cover

  plate

 

and

 

plate

 

gasket. Secure  with  

the  mounting  bolt.

4 To  avoid  water  damage

 

and

 

electrical

 

shock,

 

keep heads holders  below  horizontal.

5.Adjust the heads by loosening the lock 
nuts but do not rotate the heads more than
180°from the factory setting.When screwing 
in the heads,do not overtighten.

Keep  heads 

 at least 

1" (25 mm)  from the 
sensor. Do  

not  allow 

the  

s

d

a

e

h

to block 

the lens.

3.If a wet  location

  junction  box

 

was

 

not

used,

 

caulk

 

the wall plate  mounting  surface

with silicone

 

sealant.

Wire the Light Control

 WARNING: Turn  power  off  at  circuit  breaker 

or fuse.

fixture.

fixture

light

2.Install the mounting strap as shown using

two screws that fit your junction box.

cover

Lock Nut

Lens

40  ft.

(12 m)

8 ft.

 

(2.4 m)

 

Maximum Range

 

Maximum

 

 

Coverage Angle

 

 

 

 

 

Bottom of Sensor

Avoid aiming the control at:

 Objects  that change  temperature rapidly,

 

such as

heating  vents  and  air  conditioners.

 

These

 

heat sources could cause  false  triggering.

1. 

Turn on the circuit breaker and light switch.

NOTE:

Sensor

 

has  a 40  

second  warm  up  period

before it

 

will  

detect  motion. When

turned on, wait  1

   

minute.

2.Turn  

the  

RANGE

 

control to the medium

 

position

(halfway between  MIN  and  MAX),

 

 

and

 

the

 

ON-TIME  

control to  the

  TEST position.

first

A reas where pets or traffic may trigger

the control.

.Nearby large,light-colored objects reflecting
light may trigger the shut-off feature.Do not
point other lights at the sensor

MAX

MIN

RANGE

ON  

-TIME

TEST  1

    5

MINUTES

180°

Test and Adjustment

NOTE:

If fixture is mounted higher than 8 ft.(2.4m).

aiming the sensor down will reduce coverage distance

3.Loosen  

the  clamp  screw  in the

  sensor

 

ball joint

 and  gently  rotate  the

  sensor.

4.Walk  through  

the coverage  area

 noting where  

you are when

 

the lights

 

turn on

 

head up

  down,

 

or sideways 

 

to change the coveragearea.

 

Keep the sensor

 at least 1" (25 mm) away from the bulbs.

5.Adjust

  the

  RANGE  

as  

needed.

 

RANGE

 

set too

 

high  may

 

increase false

 

triggering.

6. 

Secure the  

sensor  

head  by tightening the

 clamp screw.

 

Do not  overtighten

  the

  screw.

7.Set

 

the

 

amount

 

of TIME

 

you  want the lights

 

to

 stay on  

after motion is detected (1  

or  

5 minutes).

 

Clamp  
Screw
 
Ball 

Joint

Aim Sensor 

Down for Short 

Coverage

Aim Sensor 

Higher for Long 

Coverage

 

Least Sensitive

 

 Most Sensitive

 

WARNING - Risk  of  re. Do not aim the heads 

at a combustible surface within 3 ft. (1 m).

 

The detector is less sensitive to motion coming 
directly at it

(also ,the LED will flash

several times when motion is detected).

Motion

Motion

Sensor

Move the sensor

2.Push the rubber plug firmly into place.

Содержание LFL2M

Страница 1: ...r electrical wiring connections obtain the services of a qualified electrician GENERAL Remove the fixture and the mounting hardware package from the box and make sure that no parts are missing by referencing the illustrations on the installation instructions To ensure success of the installation read these instructions and review the diagrams thoroughly Save these instructions for future reference...

Страница 2: ... x Note When first turned on wait about 40 seconds for the circuitry to calibrate Questions or problems Before to your retailer refer to guide in this manual troubleshooting returning the Model LFL2WHM LFL2ABZM Rubber Plug 2 Features Move switch to 1 or 5 minutes Mode Switc Installation h Summary off for one second then back on MANUAL MODE AUTO TEST If you get confused while switching modes turn t...

Страница 3: ...r and light switch NOTE Sensor has a 40 second warm up period before it will detect motion When turned on wait 1 minute 2 Turn the RANGE control to the medium position halfway between MIN and MAX and the ON TIME control to the TEST position first Areas where pets or traffic may trigger the control Nearby large light colored objects reflecting light may trigger the shut off feature Do not point oth...

Страница 4: ...g reflected from other objects may be turning the light control on and off 3 Light control is in the TEST mode and warming up off Lights flash once then stay off in manual mode Light control is detecting its own lights the light control relatively dark SPECIFICATIONS Range Up to 40 ft 12 m varies with surrounding temperature Sensing Angle Up to 180 Electrical Load Up to 24 Watt Maximum LED Power R...

Отзывы: