Floodlight Installation and
Wiring Instructions
WARNING: To avoid electrical shock. Do not attempt to install the fixture
in wet or rainy conditions. Always turn off electrical power at the circuit
breaker or by disconnecting the fuse.Only use bulbs in compliance with
manufactures specifications.
DO NOT ATTEMPT TO EXCEED MAXIMUM WATTAGE RATING.
TOOLS AND MATERIALS REQUIRED
Blade and or Phillips Head screw driver
Step Ladder(if needed)
Wiring supplires as required by electrical code:
Wire connectors
Electrical tape
UNPACK THE FIXTURE
Check the contents of the box.You should receive:
Outdoor fixture
Mounting Hardware package.
CAUTION
WARNING: Risk of fire.
Before installing your lighting fixture, thoroughly review the section titled wiring connections.
If you do not have sufficient electrical wiring experience, please refer to a do-it-yourself wiring
handbook or have your fixture installed by a qualified licensed electrician.
All electrical connections must be in accordance with local and National Electrical Code(NEC) standards.
If you are unfamiliar with proper electrical wiring connections obtain the services of a qualified electrician.
GENERAL
Remove the fixture and the mounting hardware package from the box and make sure that no parts are missing by
referencing the illustrations on the installation instructions.
To ensure success of the installation, read these instructions and review the diagrams thoroughly.
Save these instructions for future reference.
This fixture is intended to be mounted to a 4”x4”x2-1/8” deep metal outlet box.
The building structure must directly support the outlet box.
Before starting the installation, disconnect the power by turning off the circuit breaker or by removing the
fuse at the box. Turning the power off using the light switch is not sufficient to prevent electrical shock.
WIRING CONNECTIONS
Required supply circuit: 120V,60Hz.
Connect the white wire from the fixture to the white wire of the supply circuit.
Connect the black wire from the fixture to the black wire of the supply circuit.
Connect the green(or bare copper)colored wire to the grounding conductor of the supply circuit.
Use UL/CSA listed wire connectors suitable for the size, type, and nu mber or conductors.
No loose strands or loose connections should be present.Secure wire connectors with Use UL/CSA listed electrical tape.
LFL2M