POWER AND CONTROL WIRING
Power and control are arranged as separate bare-tail inputs via cords that are each 6.5’ (2m)
in length.
POWER
The power feed is as follows. The fixture must have a valid protective earth connection:
•
Voltage:
100-277VAC 50/60Hz
•
Power:
65W
Note: Acclaim recommends taking proper precautions for external surge protection, as control
and power electronics can be damaged by major events.
CONTROL
The DMX control cable has five cores:
INPUT WIRING PROTECTION
Ensure that appropriate care is taken to protect the junction where the mains and control
inputs are joined to the fixture’s feed cables.
Ensure that:
•
the mains input is derived from a suitable overload-protected supply.
•
the junction boxes have an environmental rating of at least IP66.
•
all cable access points, plus the enclosure cover are correctly sealed and moisture proof.
•
only suitable cable connectors are used within the junction boxes; Acclaim Lighting
recommends Wago® 221-series splicing connectors.
•
local codes are followed during planning and installation. Some municipalities have
specific requirements when wiring low and high voltage cables in close proximity. Such
requirements could include the use of a barrier within combined junction boxes (if used)
or particular minimum spacings between the control and power cables.
•
connections are made, inspected and certified by a qualified electrician.
Green:
DMX + (Hot)
Gray:
DMX - (Cold)
< DMX IN
> DMX OUT
White:
DMX - (Cold)
Red:
DMX + (Hot)
Black:
Ground
Blue:
Neutral
Brown:
Live
Green/yellow:
Earth