background image

9

www.acclaimlighting.com

Release 1.0a

SPECIFICATIONS

Colors 

2700K, 3000K, 3500K, 4000K, 5000K, Red, Green, Blue or Amber

Photometrics 

Up to 371 lumens per 1.64’ (0.5m) section, CRI >80

Beam angle 

160

o

Lumen maintenance (L

70

)  50,000 hours (25

o

C)

Operating voltage 

120VAC

Power consumption 

3.8W per foot, 12.4W per meter

Control 

ELV (reverse phase) or sinewave dimming, 0-10V*, DMX* 

 *

 requires the use of the optional UDM module)

 

Ingress protection 

IP66, wet and dry location - not for use where water can  

 

 

accumulate, GFCI/RCD breaker required

Impact protection 

IK08, protection against 5 joule impact 

Connectors 

10’ (3m) feed cable and UL listed AC junction box included

Finish 

Transparent sleeve, white PCB 

Mounting 

Via aluminum channel

Operating temperature 

-40

o

F to 122

o

F (-40

o

C to 50

o

C)

Certifications

2.76” (70mm)

1.64’ (0.5m) to 65.6’ (20m)

1.1”

(28mm)

1.77”

(45mm)

3.43” (87mm)

0.75”
(19mm)

2.95”
(75mm)

2.76”

(70mm)

3.07”
(78mm)

0.43”
(11mm)

0.51” (13mm)

2.87” (73mm)

Содержание Flex 120

Страница 1: ...Flex 120 User guide...

Страница 2: ......

Страница 3: ...INTRODUCTION 2 Welcome 2 Safety 2 Maintenance 2 Cleaning 2 Supplied items 3 Accessories 3 INSTALLATION 4 Mounting 4 Connections 6 Dimming control 7 FURTHER INFORMATION 8 Troubleshooting 8 Specificati...

Страница 4: ...dition to saturated single colors SAFETY The supply circuit must be fed via a Ground Fault Circuit Interrupter GFCI Residual Current Device RCD breaker Ensure that the power input is supplied from a c...

Страница 5: ...28 1m FACCH1000 6 56 2m FACCH2000 Tall profile aluminum channel 1 64 0 5m FACTPC500 3 28 1m FACTPC1000 6 56 2m FACTPC2000 Lenses for all channels Clear Frosted Opal 1 64 0 5m FACCL500 FACFL500 FACOL50...

Страница 6: ...in three lengths 0 5m 1m and 2m Each can be cut to length as required All channels have pre drilled mounting holes 3mm located at 200mm centers and are supplied with a matching number of screws M3 x 1...

Страница 7: ...ool has an indented center so that it places pressure onto the outside edges of the strip without stressing the LED emitters Wheeled install tool Once the Flex 120 strip is in place you can fit the le...

Страница 8: ...he four screws securing the lid to reveal the connectors and 6 3AL250V 5x20mm 6 3A fast acting glass fuse Note There is a termination point for an earth connection however this does not pass through t...

Страница 9: ...dimming These dimmers use an IGBT Insulated Gate Bipolar Transistor to switch the mains output at high frequencies such that they can recreate a dimmed mains sinewave with a varying overall amplitude...

Страница 10: ...IS VISIBLE WHEN EXPECTED Check that power is correctly applied to the fixture and that there is no damage to the power input cord If external DMX control is being used check that the DMX address set...

Страница 11: ...10V DMX requires the use of the optional UDM module Ingress protection IP66 wet and dry location not for use where water can accumulate GFCI RCD breaker required Impact protection IK08 protection aga...

Страница 12: ...rd party items not manufactures by Acclaim lighting During the period specified above Acclaim Lighting will replace defective parts at its expense and will absorb all expenses for warranty service and...

Страница 13: ...11 www acclaimlighting com...

Страница 14: ...www acclaimlighting com...

Отзывы: