13

www.acclaimlighting.com

Making a temporary control link

 

(AL Graze DC DMX models only)

Each XMT-350 DMX/RDM tool is supplied with a 5-pin male XLR lead that can be used to 
make a temporary control input link with the AL Graze DC DMX feed-in cable. Use a 3-pin 
terminal block, wire nuts, conn blocks or Wago® connectors to temporarily join the two 
cables:

AL Graze 

feed-in  

cable

Male XLR  

lead from 

XMT-350

DMX

 

RGB

 

RGBW

 

RGBA

 

Dynamic White

 

 

1

 Red 

Red 

Red 

2200K

 

2

 Green  Green 

Green 

3500K

 

3

 Blue 

Blue 

Blue 

5000K

 

4

 

 

Cool White

 

Amber 

DMX channel designations 

(AL Graze DC DMX models only)

The various AL Graze DC DMX variants apply their LED emitters to DMX channels in different 
ways, as summarized in the table below. 

The channel allocations above are shown beginning at DMX address 1. When you configure 
a fixture with an alternative DMX address, that value will become the first channel in the list 
shown above and the other channels will increment from there.

Содержание AL Graze DC

Страница 1: ...AL Graze DC CV and DMX User guide...

Страница 2: ......

Страница 3: ...ing and replacing brackets 6 Fitting a glare shield 7 Fitting a louver 7 Fitting extender bars 8 Power and control wiring 9 Extending fixture runs beyond 12 feet 10 DMX channel designations 13 Operati...

Страница 4: ...s required use a MLV Magnetic Low Voltage dimmable transformer such as the M Series from Acclaim Lighting see page 11 AL Graze DC DMX controlled by an external DMX input using separate channels for ea...

Страница 5: ...nal flat brackets and grub screws Link cables CV DMX 1 30cm AGELC1 AGDLC1 5 1 5m AGELC5 AGDLC5 10 3m AGELC10 AGDLC10 Feed cables plus end cap CV DMX 10 3m AGEFC10 AGDFC10 End caps CV DMX AGEEC AGDEC T...

Страница 6: ...nued Louver 1 30cm AGLV1 4 122cm AGLV4 Extender bar 12 30cm AGEB12 24 60cm AGEB24 Dimmable transformers for AL Graze DC CV models 120VAC input 150W powers 1 x 12 run M150L24DC 120VAC input 300W powers...

Страница 7: ...riate screws bolts If necessary use a 1 16th 1 5mm Allen wrench to loosen each mount bracket to allow them to slide along the length of the fixture to the required position before re tightening Note I...

Страница 8: ...n slide the bracket to the center of the fixture where the rails widen to allow the feet of the bracket to be released Where AL Graze DC fixtures do not need to be tilted and need to be closer to the...

Страница 9: ...glare shield with the main groove on either side of the emitter housing 2 Press the ledge into the groove until it snaps into place Optional glare shield Fitting a louver Optional louvers are availabl...

Страница 10: ...ze DC fixture Note When feeding cables through the extender bar check for any metal burrs that may have formed during manufacture take care not to snag cables Slot in underside can be used to feed cab...

Страница 11: ...Low Voltage dimmable transformer such as the M Series from Acclaim Lighting AL Graze DC DMX units require both a regulated 24VDC power input as well as DMX control and so use 5 pin connectors The fin...

Страница 12: ...ol links while terminating and replacing the power input with a new source End of previous 12 fixture run powered from original 24VDC source Beginning of new up to 12 fixture run powered from new 24VD...

Страница 13: ...DC supply required by AL Graze DC CV fixtures Available in the following variants 120VAC input 150W capacity can power 1 x 12 run M150L24DC 120VAC input 300W capacity can power 2 x 12 runs M300L24DC 2...

Страница 14: ...not exceeded AL Graze DC feed in and link cables use 18AWG wires for their power connections It is possible to increase the total fixture cable lengths by using custom cables with larger power cores P...

Страница 15: ...Male XLR lead from XMT 350 DMX RGB RGBW RGBA Dynamic White 1 Red Red Red 2200K 2 Green Green Green 3500K 3 Blue Blue Blue 5000K 4 Cool White Amber DMX channel designations AL Graze DC DMX models only...

Страница 16: ...buttons to highlight the RDM function and press the button to select The XMT 350 will search for RDM devices and after a short while the XMT 350 will display a list of all located fixtures The fixture...

Страница 17: ...multiple fixtures in a pre arranged daisy chain configuration 2 Power on the fixture s and the XMT 350 3 On the XMT 350 press the MODE button then use the arrow buttons to highlight the SEND function...

Страница 18: ...power input cord DMX models Use an RDM tool such as the Swisson XMT 350 to check the settings and internal temperature of the fixture DMX models Using an RDM tool check that the DMX address set withi...

Страница 19: ...ge dimming DMX DMX 512A RDM configuration Ingress protection IP66 wet location Fixture connectors Chogori Standard 22 series IP67 rated CV 2 pin DC power DMX 5 pin combined DC power control Maximum le...

Страница 20: ...lighting During the period specified above Acclaim Lighting will replace defective parts at its expense and will absorb all expenses for warranty service and repair labor by reason of defects in mate...

Страница 21: ......

Страница 22: ...www acclaimlighting com...

Отзывы: