Extending fixture runs beyond 12 feet
Due to the limited current carrying capacity of the internal power buses, runs of AL Graze
DC fixtures must not exceed 12’ (3.65m). Where longer lengths are required you can either
arrange separate parallel runs of up to 12’ or use the optional T-cable [AGDT1] from Acclaim
Lighting. The T-cable is applied between separate 12’ runs, where it continues the DMX
control links while terminating and replacing the power input with a new source:
End of previous 12’ fixture
run - powered from original
24VDC source
Beginning of new
(up to) 12’ fixture run
- powered from new
24VDC source, via
the T-cable
T-cable: continues the DMX
control connection while
terminating and replacing
the power connection
Protect the
connections in
a junction box
with appropriate
ingress protection
Where the T-cable body needs to be
secured, Acclaim Lighting recommends
the use of a standard 3/4” pipe strap:
3/4” pipe strap
(not supplied)
T-cable lengths:
Connector to connector - 12” (305mm)
Center point to bare tails - 12” (305mm)