
ACCESS VIRUS RACK
183
All abouts Inputs
Input Level Indicator
Alternatively, the RATE LEDs of LFO 1
and 2 can also serve as level indicators
for the left and right external audio
inputs. To this end, go to the CTRL menu,
select the menu item SYSTEM, and set
the Parameter LED mode to Input. When
the parameter is set to Auto, the Virus
automatically activates this level indica-
tor mode when the selected SINGLE pro-
gram accesses the external audio inputs.
The LEDs will flash rapidly to indicate
that the inputs are being overloaded.
Der korrekte Pegel sollte an dem Gerät
eingestellt werden, welches die analo-
gen Signale liefert, da so die AD-Wand-
ler des Virus optimal ausgenutzt werden.
Der Parameter INPUT Boost sollte nur in
Ausnahmefällen zur Pegelanhebung ver-
wendet werden, da er erst nach den AD-
Wandlern das Signal digital verstärkt,
und somit die Aussteuerung der Wandler
selbst nicht beeinflusst.
You should dial in a suitable input level
on the device that is sending the analog
signals. The reason for this is that you
want to feed the highest possible clean
signal level to the analog-to-digital con-
verters of the Virus so that they will
deliver the best possible performance.
You should only turn up INPUT BOOST as
a last resort because it is located post A/
D converters and boost signals digitally,
which of course doesn’t affect the level
of the converters.
Signals within the Virus may also be
overloaded and may distort when their
levels are too high. Inherently, a virtual
analog synthesizer’s resonating filters
and high level of polyphony lend signal
levels considerable dynamic potential.
We could only rule out this type of dis-
tortion entirely by lowering the funda-
mental output of the device significantly
or by limiting specific parameters. How-
ever, this type of problem occurs only in
a very few, very specific scenarios. Since
the problem is so context-related, we
chose not to lower the device’s output
power or limit its parameters. Instead,
we recommend that you simply lower
signal levels (Patch Volume, etc.) to pre-
vent undesirable distortion.
To help you keep an eye on signal levels,
you can activate LED mode to visually
monitor the levels and amount of distor-
tion of the two audio outputs.
Содержание VIRUS C SERIES
Страница 1: ......
Страница 3: ...Table Of Contents ...
Страница 7: ...ACCESS VIRUS RACK 5 ...
Страница 11: ...ACCESS VIRUS RACK 9 ...
Страница 15: ...Introduction ...
Страница 33: ...ACCESS VIRUS RACK 31 The Second Filter ...
Страница 35: ...ACCESS VIRUS RACK 33 Filter Routing Her is the filter routings capabilities of the Virus ...
Страница 54: ...52 CHAPTER 4 Introduction ...
Страница 55: ...Concept and Operation ...
Страница 60: ...58 CHAPTER 5 Concept and Operation ...
Страница 61: ...Operation ...
Страница 67: ...All About The Memory ...
Страница 70: ...68 CHAPTER 7 All About The Memory ...
Страница 71: ...Modmatrix And Definables ...
Страница 75: ...Master Clock And Midi Clock ...
Страница 77: ...The Effects Section ...
Страница 79: ...Audio Inputs ...
Страница 83: ...Audio Routing ...
Страница 85: ...Categories ...
Страница 87: ...Random Patch Generator ...
Страница 90: ...88 CHAPTER 14 Random Patch Generator ...
Страница 91: ...Additional Functions ...
Страница 94: ...92 CHAPTER 15 Additional Functions ...
Страница 95: ...The Parameters ...
Страница 132: ...130 CHAPTER 16 The Parameters ...
Страница 163: ...The Vocoder ...
Страница 169: ...The Virus and Sequencers ...
Страница 173: ...ACCESS VIRUS RACK 171 Organizational Information ...
Страница 180: ...178 CHAPTER 18 The Virus and Sequencers ...
Страница 181: ...Tips Tricks Words Of Wisdom ...
Страница 201: ...ACCESS VIRUS RACK 199 MIDI ...
Страница 204: ...202 CHAPTER 19 Tips Tricks Words Of Wisdom ...
Страница 205: ...Appendix ...
Страница 215: ...ACCESS VIRUS RACK 213 FCC Information U S A ...
Страница 217: ...ACCESS VIRUS RACK 215 FCC Information CANADA ...
Страница 219: ...ACCESS VIRUS RACK 217 Other Standards Rest of World ...
Страница 223: ...ACCESS VIRUS RACK 221 Garantie Bestimmung ...
Страница 225: ...ACCESS VIRUS RACK 223 Warranty ...
Страница 226: ...224 CHAPTER 20 Appendix ...
Страница 227: ...ACCESS VIRUS RACK 225 Warranty ...